Lenovo RD120 manual RAID Configuration Utility menu choices, Configuring the controller

Page 102

RAID Configuration Utility menu choices

The following choices are on the IBM ServeRAID Configuration Utility menu:

vArray Configuration Utility

Select this choice to create, manage, or delete arrays, or to initialize drives.

vSerial Select Utility

Select this choice to configure the controller interface definitions or to configure the physical transfer and SAS address of the selected drive.

vDisk Utilities

Select this choice to format a disk or verify the disk media. Select a device from the list and read the instructions on the screen carefully before making a selection.

Configuring the controller

To configure a RAID array on the server, complete the following steps:

1.Turn on the server.

2.When the message Press <CTRL><A> for IBM ServeRAID Configuration Utility appears, press Ctrl+A.

3.Select Array Configuration Utility.

4.Select Create Array.

5.From the list of ready drives, select the drives that you want to group into the array.

6.From the list of RAID levels available, select the one you want to use, such as RAID-1.

7.(Optional) Type an identifier for the array.

8.When you are prompted for the array build method, select Quick Init.

9.Follow the instructions on the screen to complete the configuration; then, select Done to exit.

10.Restart the server.

Viewing the configuration

To view information about the RAID array, complete the following steps:

1.Turn on the server.

2.When the message Press <CTRL><A> for IBM ServeRAID Configuration Utility appears, press Ctrl+A.

3.Select Array Configuration Utility.

4.Select Manage Arrays.

5.Select an array and press Enter.

6.To exit from the program, press Esc.

Using the baseboard management controller

The baseboard management controller provides basic service-processor environmental monitoring functions for the server. If an environmental condition exceeds a threshold or if a system component fails, the baseboard management controller lights LEDs to help you diagnose the problem and also records the error in the BMC system event log.

88ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide

Image 102
Contents User Guide Page User Guide Page Contents Configuring the server Safety Page To Connect To Disconnect Page Safety Statement Safety Page ThinkServer RD120 server Related documentation Features and specifications What your server offers Baseboard management controllerEasyManage software Integrated network supportLarge data-storage and hot-swap capability Memory mirroring Easy LED DiagnosticsRedundant cooling and power capabilities Online-spare memoryReliability, availability, and serviceability features Systems-management capabilitiesTCP/IP offload engine TOE support Server controls, LEDs, and power ThinkServer EasyStartupFront view Tape drive bay Rear view 10 USB 3 connector 20 Power supply Server power features Turning on the serverThinkServer RD120 server Page Installing optional devices Server componentsCover VRM System-board optional-device connectors PCI riser-card adapter connectors Power-backplane-board connectorsSystem-board internal cable connectors System-board external connectors System-board switches and jumpers Switch Number Default value Description System-board LEDs LEDRiser-card assembly LEDs Diagnostics panel LEDCPU RAID Installation guidelines Working inside the server with the power on System reliability guidelinesHandling static-sensitive devices Removing the coverRemoving the riser-card assembly 1 Access holes 2 Release tabs Installing the riser-card assembly Removing the microprocessor air baffleFinger holes Installing the microprocessor air baffle Removing the Dimm air baffle Installing the Dimm air baffle Installing an adapter PCI riser card 1 Access holes 2 Release tabs 1 Access holes 2 Guide 3 Release tabs 4 Guide Removing an adapter To remove an adapter, complete the following steps1 Access holes 2 Release tabs Replacing the RAID SAS controller RAID controller Installing a hard disk drive Inch drivesInch drives Removing a hard disk drive Installing an optional tape drive Installing a Sata tape drive in a 3.5-inch model serverInstalling optional devices 1 Sata tape cable connector 2 Sata tape cable Installing a Sata tape drive in a 2.5-inch model server Installing a microprocessor Installing optional devices Microprocessor-socket dust cover Installing optional devices Notches Installing optional devices Installing a memory module Pair Dimm connectorsDimm Memory mirroring Online-spare memory Configuration that you use, install the largest DIMMs first Installing a hot-swap power supply Removing a memory moduleTo install an ac power supply, complete the following steps Power cord connectors Removing a hot-swap power supply Installing a fanRemoving a fan Removing the fan-bracket assembly Fan bracket Installing the fan-bracket assembly Replacing the CD-RW/DVD drive Completing the installation Installing the cover Connecting the cablesFront view Updating the server configuration Rear viewInstalling optional devices Page Using the Configuration/Setup Utility program Starting the Configuration/Setup Utility program Configuration/Setup Utility menu choicesAdvanced Setup Administrator PasswordPower-on Password Memory SettingsCPU Options RSA II SettingsStatic IP Settings PCI Bus ControlReboot System on NMI BMC Post Watchdog TimeoutBMC Serial Port Access Mode BMC Network ConfigurationRestore Settings PasswordsSave Settings Load Default SettingsAdministrator password Boot block recovery jumper J42 Using the RAID Configuration Utility program Starting the RAID Configuration Utility programViewing the configuration RAID Configuration Utility menu choicesConfiguring the controller Using the baseboard management controllerUsing the baseboard management controller utility programs Configuring the Gigabit Ethernet controllersPage Appendix. Notices Trademarks Important notesWaste electrical and electronic equipment Weee notices Recycling statements for Japan Battery return program For the European UnionFederal Communications Commission FCC statement German Ordinance for Work gloss statementElectronic emission notices Industry Canada Class a emission compliance statementAvis de conformité à la réglementation d’Industrie Canada European Union EMC Directive conformance statementTaiwanese Class a warning statement Page Index Installing VRM Index Video connector rear Voltage regulator module, installing Page Part Number 46U0861

RD120 specifications

The Lenovo RD120 is a robust server specifically designed for small to medium-sized businesses looking for reliable performance and efficiency in their IT infrastructure. This tower server is known for its cost-effectiveness while delivering powerful functionalities that support a wide range of applications, from file sharing to email hosting.

One of the main features of the RD120 is its support for Intel's Xeon processors, providing businesses the scalability they need. It can accommodate up to two Xeon processors, enhancing multitasking capabilities and improving overall performance. This makes it suitable for handling various workloads and running multiple applications simultaneously.

In terms of memory, the RD120 supports up to 32GB of DDR3 RAM, offering excellent speed and efficiency for data processing. With multiple DIMM slots available, businesses can upgrade their memory easily depending on their growing needs, ensuring longevity and adaptability for future workloads.

Storage is another strong aspect of the Lenovo RD120. It offers flexible configuration options, supporting up to four hot-swap SATA hard drives and RAID configurations. This means businesses can choose the optimal balance between performance and redundancy, ensuring that data is always safe and accessible. The option for SSDs enhances speed and reliability, catering to data-intensive applications.

Networking capabilities in the RD120 are impressive, with integrated Gigabit Ethernet ports for fast and dependable network connectivity. This feature is crucial for maintaining fast data transfer speeds and ensuring seamless operation across the network.

The server’s design is focused on ease of use and management, featuring a tool-less chassis that simplifies upgrades and maintenance. Additionally, Lenovo provides management tools such as the Integrated Management Module, allowing for remote monitoring and administration. This is essential for any business looking to optimize their server performance without the need for constant on-site management.

Security features are built into the RD120, with options for encryption and secure boot firmware. These capabilities help protect sensitive information and maintain system integrity, aligning with business needs in today’s security-conscious environment.

In conclusion, the Lenovo RD120 comprises a blend of power, flexibility, and user-centric design, catering perfectly to the needs of small and medium businesses. Its efficient performance, robust storage options, and management features make it a valuable asset for any organization looking to establish a reliable and scalable IT infrastructure.