vOrange on a component or an orange label on or near a component indicates that the component can be hot-swapped, which means that if the server and operating system support hot-swap capability, you can remove or install the component while the server is running. (Orange can also indicate touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap component for any additional procedures that you might have to perform before you remove or install the component.

vWhen you are finished working on the server, reinstall all safety shields, guards, labels, and ground wires.

vFor a list of Lenovo optional devices for the server, see http://www/.lenovo.com/ thinkserver.

System reliability guidelines

To help ensure proper system cooling and system reliability, make sure that the following requirements are met:

vEach of the drive bays has a drive or a filler panel and electromagnetic compatibility (EMC) shield installed in it.

vIf the server has redundant power, each of the power-supply bays has a power supply installed in it.

Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply. See the documentation that comes with each dc power supply.

vThere is adequate space around the server to allow the server cooling system to work properly. Leave approximately 50 mm (2.0 in.) of open space around the front and rear of the server. Do not place objects in front of the fans. For proper cooling and airflow, replace the server cover before you turn on the server. Operating the server for extended periods of time (more than 30 minutes) with the server cover removed might damage server components.

vYou have followed the cabling instructions that come with optional adapters.

vYou have replaced a failed fan within 48 hours.

vYou have replaced a hot-swap drive within 2 minutes of removal.

vYou do not operate the server without the air baffles installed. Operating the server without the air baffles might cause the microprocessors to overheat.

vMicroprocessor socket 2 always contains either a heat-sink filler or a microprocessor and heat sink.

Working inside the server with the power on

Attention: Static electricity that is released to internal server components when the server is powered-on might cause the server to halt, which could result in the loss of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap or other grounding system when working inside the server with the power on.

The server supports hot-plug, hot-add, and hot-swap devices and is designed to operate safely while it is turned on and the cover is removed. Follow these guidelines when you work inside a server that is turned on:

vAvoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts before working inside the server; do not wear cuff links while you are working inside the server.

vDo not allow your necktie or scarf to hang inside the server.

30ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide

Image 44
Contents User Guide Page User Guide Page Contents Configuring the server Safety Page To Connect To Disconnect Page Safety Statement Safety Page ThinkServer RD120 server Related documentation Features and specifications What your server offers Baseboard management controllerLarge data-storage and hot-swap capability EasyManage softwareIntegrated network support Easy LED Diagnostics Redundant cooling and power capabilitiesMemory mirroring Online-spare memoryTCP/IP offload engine TOE support Reliability, availability, and serviceability featuresSystems-management capabilities Front view Server controls, LEDs, and powerThinkServer EasyStartup Tape drive bay Rear view 10 USB 3 connector 20 Power supply Server power features Turning on the serverThinkServer RD120 server Page Installing optional devices Server componentsCover VRM System-board optional-device connectors PCI riser-card adapter connectors Power-backplane-board connectorsSystem-board internal cable connectors System-board external connectors System-board switches and jumpers Switch Number Default value Description System-board LEDs LEDRiser-card assembly LEDs Diagnostics panel LEDCPU RAID Installation guidelines Working inside the server with the power on System reliability guidelinesHandling static-sensitive devices Removing the coverRemoving the riser-card assembly 1 Access holes 2 Release tabs Installing the riser-card assembly Removing the microprocessor air baffleFinger holes Installing the microprocessor air baffle Removing the Dimm air baffle Installing the Dimm air baffle Installing an adapter PCI riser card 1 Access holes 2 Release tabs 1 Access holes 2 Guide 3 Release tabs 4 Guide Removing an adapter To remove an adapter, complete the following steps1 Access holes 2 Release tabs Replacing the RAID SAS controller RAID controller Installing a hard disk drive Inch drivesInch drives Removing a hard disk drive Installing an optional tape drive Installing a Sata tape drive in a 3.5-inch model serverInstalling optional devices 1 Sata tape cable connector 2 Sata tape cable Installing a Sata tape drive in a 2.5-inch model server Installing a microprocessor Installing optional devices Microprocessor-socket dust cover Installing optional devices Notches Installing optional devices Installing a memory module Pair Dimm connectorsDimm Memory mirroring Online-spare memory Configuration that you use, install the largest DIMMs first Installing a hot-swap power supply Removing a memory moduleTo install an ac power supply, complete the following steps Power cord connectors Removing a hot-swap power supply Installing a fanRemoving a fan Removing the fan-bracket assembly Fan bracket Installing the fan-bracket assembly Replacing the CD-RW/DVD drive Completing the installation Front view Installing the coverConnecting the cables Updating the server configuration Rear viewInstalling optional devices Page Using the Configuration/Setup Utility program Starting the Configuration/Setup Utility program Configuration/Setup Utility menu choicesAdministrator Password Power-on PasswordAdvanced Setup Memory SettingsRSA II Settings Static IP SettingsCPU Options PCI Bus ControlBMC Post Watchdog Timeout BMC Serial Port Access ModeReboot System on NMI BMC Network ConfigurationPasswords Save SettingsRestore Settings Load Default SettingsAdministrator password Boot block recovery jumper J42 Using the RAID Configuration Utility program Starting the RAID Configuration Utility programRAID Configuration Utility menu choices Configuring the controllerViewing the configuration Using the baseboard management controllerUsing the baseboard management controller utility programs Configuring the Gigabit Ethernet controllersPage Appendix. Notices Trademarks Important notesWaste electrical and electronic equipment Weee notices Recycling statements for Japan Battery return program For the European UnionGerman Ordinance for Work gloss statement Electronic emission noticesFederal Communications Commission FCC statement Industry Canada Class a emission compliance statementTaiwanese Class a warning statement Avis de conformité à la réglementation d’Industrie CanadaEuropean Union EMC Directive conformance statement Page Index Installing VRM Index Video connector rear Voltage regulator module, installing Page Part Number 46U0861

RD120 specifications

The Lenovo RD120 is a robust server specifically designed for small to medium-sized businesses looking for reliable performance and efficiency in their IT infrastructure. This tower server is known for its cost-effectiveness while delivering powerful functionalities that support a wide range of applications, from file sharing to email hosting.

One of the main features of the RD120 is its support for Intel's Xeon processors, providing businesses the scalability they need. It can accommodate up to two Xeon processors, enhancing multitasking capabilities and improving overall performance. This makes it suitable for handling various workloads and running multiple applications simultaneously.

In terms of memory, the RD120 supports up to 32GB of DDR3 RAM, offering excellent speed and efficiency for data processing. With multiple DIMM slots available, businesses can upgrade their memory easily depending on their growing needs, ensuring longevity and adaptability for future workloads.

Storage is another strong aspect of the Lenovo RD120. It offers flexible configuration options, supporting up to four hot-swap SATA hard drives and RAID configurations. This means businesses can choose the optimal balance between performance and redundancy, ensuring that data is always safe and accessible. The option for SSDs enhances speed and reliability, catering to data-intensive applications.

Networking capabilities in the RD120 are impressive, with integrated Gigabit Ethernet ports for fast and dependable network connectivity. This feature is crucial for maintaining fast data transfer speeds and ensuring seamless operation across the network.

The server’s design is focused on ease of use and management, featuring a tool-less chassis that simplifies upgrades and maintenance. Additionally, Lenovo provides management tools such as the Integrated Management Module, allowing for remote monitoring and administration. This is essential for any business looking to optimize their server performance without the need for constant on-site management.

Security features are built into the RD120, with options for encryption and secure boot firmware. These capabilities help protect sensitive information and maintain system integrity, aligning with business needs in today’s security-conscious environment.

In conclusion, the Lenovo RD120 comprises a blend of power, flexibility, and user-centric design, catering perfectly to the needs of small and medium businesses. Its efficient performance, robust storage options, and management features make it a valuable asset for any organization looking to establish a reliable and scalable IT infrastructure.