Hitachi HUS157336EL3600, HUS157373EL3800, HUS157373EL3600, HUS157336EL3800 Pin assignment

Page 33

11Pin assignment

11.1SCSI Bus Connector C1

Table 11.1 Pin assignment of SCSI Bus Connector C1

(WIDE, Single-ended mode)

Signal Name

Connector

 

Cable

Connector

Signal Name

 

contact

conductor

contact

 

 

No.

 

No.

No.

 

GND

1

1

 

2

35

-DB(12)

GND

2

3

 

4

36

-DB(13)

GND

3

5

 

6

37

-DB(14)

GND

4

7

 

8

38

-DB(15)

GND

5

9

 

10

39

-DB(P1)

GND

6

11

 

12

40

-DB(0)

GND

7

13

 

14

41

-DB(1)

GND

8

15

 

16

42

-DB(2)

GND

9

17

 

18

43

-DB(3)

GND

10

19

 

20

44

-DB(4)

GND

11

21

 

22

45

-DB(5)

GND

12

23

 

24

46

-DB(6)

GND

13

25

 

26

47

-DB(7)

GND

14

27

 

28

48

-DB(P0)

GND

15

29

 

30

49

GND

DIFFSENS

16

31

 

32

50

GND

TERMPWR

17

33

 

34

51

TERMPWR

TERMPWR

18

35

 

36

52

TERMPWR

Reserved

19

37

 

38

53

Reserved

GND

20

39

 

40

54

GND

GND

21

41

 

42

55

-ATN

GND

22

43

 

44

56

GND

GND

23

45

 

46

57

-BSY

GND

24

47

 

48

58

-ACK

GND

25

49

 

50

59

-RST

GND

26

51

 

52

60

-MSG

GND

27

53

 

54

61

-SEL

GND

28

55

 

56

62

-C/D

GND

29

57

 

58

63

-REQ

GND

30

59

 

60

64

-I/O

GND

31

61

 

62

65

-DB(8)

GND

32

63

 

64

66

-DB(9)

GND

33

65

 

66

67

-DB(10)

GND

34

67

 

68

68

-DB(11)

Drawing No. Sheet No. Revision 5

K6602906

33/46

2003/6/12

Image 33
Contents OEM Manual ScsiRevision Control K6602906 2003/6/12General cautions for safety Headline of safety cautionInfluence for environment Safety cautions for this product Warranty and Limited Liability Table of Contents Page Models FeaturesStandards and Related Documents Characteristics CharacteristicsDescription K6602906 10/46 2003/6/12Environmental conditions and reliability Environmental conditions and reliabilityK6602906 11/46 2003/6/12 Vibration test direction Shock test direction Power measurement Operating UnitWUltrastar 15K73-73 Ultrastar 15K73-36 IOs per second DC Power Requirement DC power InterfaceCurrent transition for +12V Power supply currentSpindle Start and Stop Start and Stop Time Start and Stop timePage Connecting Methods Interface Cable Daisy ChainK6602906 18/46 2003/6/12 Page Scsi Interface Page Scsi Commands Supported Mounting and Handling K6602906 24/46 2003/6/12 Good case Bad caseK6602906 25/46 2003/6/12 Mounting dimensionsK6602906 26/46 2003/6/12 Temperature Limits unit CPrecautions for handling Maintenance Physical interface Interface connectorsInterface cable WIDE, LVD mode Interface cable WIDE, Single-ended modeConnector Layout Wide LVD drive 101.6±0.25 SCA-2 LVD drive Dimension35±0.25 50.8±0.5 K6602906 32/46 2003/6/12Pin assignment Pin assignment of Scsi Bus Connector C1 WIDE, LVD mode GND BSY +BSY ATN Pin assignment of Scsi Bus Connector C1 SCA-2, LVD modePin assignment of Auxiliary Connector C4 Wide LVD drive Pin assignment of Option Jumper Connector C3 Wide LVD driveK6602906 37/46 2003/6/12 K6602906 38/46 2003/6/12 NW drive NC driveJumper connector layout Wide LVD drive Jumper Socket settingSAC-2 LVD drive Jumper connector layout SCA-2 LVD driveScsi ID # Option Jumper Connector C3Scsi ID K6602906 43/46 2003/6/12 Disable Auto StartEnable Delayed Start Force Single-Ended bus modeScsi bus Terminator Power Write ProtectK6602906 45/46 2003/6/12 Extension connector Jumper socketK6602906 46/46 2003/6/12

HUS157373EL3800, HUS157373EL3600, HUS157336EL3600, HUS157336EL3800 specifications

The Hitachi HUS157336EL3600 and HUS157373EL3600, along with the HUS157336EL3800 and HUS157373EL3800, are part of the Hitachi Virtual Storage Platform (VSP) E-series, designed to address the demanding needs of enterprise environments. These high-capacity storage systems are tailored for data-intensive applications, ensuring reliability, performance, and scalability.

A standout feature of the HUS157336EL and HUS157373EL series is their exceptional storage capacity, with the former offering up to 36TB and the latter providing up to 73TB of available storage. This substantial capacity makes them ideal for organizations storing vast amounts of unstructured data, including multimedia files, large databases, and backup solutions.

Both models leverage advanced data protection technologies. Hitachi’s Data Protection Manager (DPM) technology provides robust backup and recovery solutions, enabling businesses to safeguard their critical information effortlessly. Additionally, features like snapshots and replication guarantee data integrity and accessibility, even in the event of hardware failure or accidental deletions.

Performance is another critical aspect. These systems utilize Hitachi’s proprietary Flash of Flash (FoF) technology, which significantly enhances input/output operations per second (IOPS) while minimizing latency. This is particularly beneficial for mission-critical applications that require rapid data retrieval and processing.

Moreover, the HUS157336EL and HUS157373EL series support automated tiering and storage optimization. This allows organizations to manage their storage resources efficiently, moving less frequently accessed data to lower-cost storage media without any disruption to daily operations. This feature not only helps manage costs but also enhances the overall performance of the system.

Both the HUS157336EL3600 and HUS157373EL3600 are built with energy efficiency in mind, featuring power-saving technologies that reduce energy consumption while maintaining top-notch performance. This focus on sustainability aligns with the growing need for organizations to operate environmentally responsibly.

In summary, the Hitachi HUS157336EL3600, HUS157373EL3600, HUS157336EL3800, and HUS157373EL3800 exemplify cutting-edge storage solutions that cater to the needs of modern enterprises. With high capacity, advanced data protection, exceptional performance, automated tiering, and energy efficiency, these systems represent a significant investment in securing and managing critical data assets for businesses across various industries.