Tag4*1 | AUTO ADJUST*2 |
| Automatically adjusts the Image Position and H.Size settings and Fine settings. | ||||||||||
(Analog |
|
| Press “SELECT” to activate Auto Adjustment. Please use test pattern, which is included | ||||||||||
input only) |
|
| in the enclosed |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
| SIGNAL ADJUST |
| Determines when the auto adjustment is activated automatically. | ||||||||||
|
|
| The choices are “SIMPLE” and “FULL”. Press “Left” or “Right” to select. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Contrast |
|
|
|
| |||||
|
|
| SIMPLE |
| O |
| X |
|
|
|
| ||
|
|
| FULL |
| O |
| O |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| O: Automatic Adjustment | X: No Automatic Adjustment |
|
| |||||||
|
|
| NOTE: Automatic Adjustment does not work at resolutions less than 800x600 resolution. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
| AUTO ADJUST |
| Determines the automatic adjustment level for Auto Adjust. The choices are “SIMPLE”, | ||||||||||
| LEVEL |
| “FULL” and “DETAIL”. Press “Left” or “Right” to select. Refer to the below table. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| Size, Fine, Position | Contrast |
| Black Level |
| Time |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| SIMPLE | O |
| X |
|
| X |
| 1 second |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| FULL | O |
| O |
|
| X |
| 1.5 seconds |
| |
|
|
| DETAIL* | O |
| O |
|
| O |
| 5 seconds |
| |
|
|
| O: Automatic Adjustment | X: No Automatic Adjustment |
|
| |||||||
|
|
| * “DETAIL” activates automatic long cable (skew, peaking) adjustment. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
| The Advanced No Touch Auto Adjust function is able to recognize new signals even | |||||||||||
|
|
| when neither the resolution nor the refresh rate has changed. If several PCs are | ||||||||||
|
|
| connected to the monitor, and each transmit very similar (or even the same) signals in | ||||||||||
|
|
| terms of resolution and refresh rates, the monitor recognizes that there is a new signal | ||||||||||
|
|
| and automatically optimizes the picture without the need for any action on the part of the | ||||||||||
|
|
| user. |
|
|
|
|
|
|
|
|
|
|
|
|
| OFF: |
|
|
|
|
|
| ||||
|
|
| ON: If a change in signal is detected | ||||||||||
|
|
| settings for the new signal. If no change in the signal is detected then | ||||||||||
|
|
| activate. The screen will be blank while the monitor optimizes the signal. | ||||||||||
|
|
| OPTION: Functions the same as ON, except that the screen does not go blank when the | ||||||||||
|
|
| monitor makes adjustments for changes in signal, allowing the monitor to display the new | ||||||||||
|
|
| signal faster. When using an external switching device to connect 2 or more PCs to the | ||||||||||
|
|
| monitor, using the ON or OPTION settings is suitable. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
| AUTO CONTRAST*2 |
| Adjusts the image displayed for | ||||||||||
|
|
| Any adjustment requires the image to have white portions. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
| CONTRAST |
| Adjusts the image brightness and contrast in relation to the background. | ||||||||||
|
|
| Press “Left” or “Right” to adjust. |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
| AUTO BLACK LEVEL*2 |
| Automatically adjusts the black level. Any adjustment requires the image to have black | ||||||||||
|
|
| portions. Press “SELECT” to activate Auto Adjust. |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
| BLACK LEVEL |
| Adjusts the RGB black level by input signal level. |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |||
Tag5 | H.POSITION |
| Controls Horizontal Image Position within the display area of the LCD. | ||||||||||
|
|
| Press “Left” or “Right” to adjust. |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
| V.POSITION |
| Controls Vertical Image Position within the display area of the LCD. | ||||||||||
|
|
| Press “Left” or “Right” to adjust. |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||
| H.SIZE*1 |
| Adjusts the horizontal size of the screen. |
|
| ||||||||
| (Analog input only) |
| If the “AUTO Adjust function” do not give you a satisfactory picture setting, a further | ||||||||||
|
|
| tuning can be performed using the “H.Size (V.Size)” function (dot clock). For this a Moiré | ||||||||||
|
|
| test pattern could be used. This function may alter the width of the picture. Use left/Right | ||||||||||
|
|
| Menu to center the image on the screen. If the H.Size (V.Size) is incorrectly calibrated, | ||||||||||
|
|
| vertical bands will appear. The image should be homogeneous. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
| FINE*1 |
| Improve focus, clarity and image stability by increasing or decreasing this setting. | ||||||||||
| (Analog input only) |
| If the “Auto Adjust function” and the “H.Size” function do not give you a satisfactory | ||||||||||
|
|
| picture setting, a fi ne tuning can be performed using the “Fine” function. For this a Moiré | ||||||||||
|
|
| test pattern could be used. If the Fine value is incorrectly calibrated, horizontal lines will | ||||||||||
|
|
| appear on the display. The image should be homogeneous. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
| AUTO FINE*1 |
| This function automatically and periodically adjusts the “FINE” setting for change in signal | ||||||||||
| (Analog input only) |
| condition. This function adjusts approximately every 33 minutes. | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
| H.RESOLUTION |
| Adjusts the horizontal size by increasing or decreasing the setting. | ||||||||||
|
|
| Press “Right” button to expand the width of the image on the screen. | ||||||||||
|
|
| Press “Left” button to narrow the width of the image on the screen. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
*1 Only for PA241W. |
|
|
|
|
|
|
| *2 This item does not reset by FACTORY PRESET (Tag7). |
English