Lexmark 952DTE, 952DE, 950DE, 954DE, 954DHE manual Electrical specifications, Power requirements

Page 19

Printer specifications

19

Electrical specifications

 

Printer model

Electrical specification

 

 

 

 

C950 SFP lowvoltage models

100–127 V at 50–60Hz, nominal

 

 

90–137 V, extreme

 

 

 

 

C950 SFP highvoltage models

220–240 V at 50–60Hz, nominal (available only in some countries)

 

 

198–259 V, extreme

 

 

 

 

X95x MFP lowvoltage models

100–127 V at 50–60Hz, nominal

 

 

90–137 V, extreme

 

 

 

 

X95x MFP highvoltage models

220–240 V at 50–60Hz, nominal (available only in some countries)

 

 

198–259 V, extreme

 

 

 

Warning—Potential Damage: Do not use voltage converters with printers.

Power requirements

The following table specifies the nominal average power requirements for the base configuration, including fuser power.

Printing state

C950

X950de

X952de

X952dte

X954de

X954dhe

Average power while printing continuously

Onesided (simplex) Twosided (duplex)

680W

670W

675W

650W

710W

700W

750W

725W

Average power while idle

Hibernate mode

Ready mode

Sleep mode

1.0W 95 W 15 W

1.0W

110 W

17 W

1.0W

115 W

17 W

1.0W 120 W 17 W

Average power while copying

Copy

Not applicable

810 W

830 W

850 W

Average power while scanning

Scan

Not applicable

125 W

130 W

135 W

 

 

 

 

 

Maximum current while printing

 

 

 

 

 

 

 

 

100 V

15.0 A

15.0 A

15.0 A

15.0 A

120 V

13.2 A

13.2 A

13.2 A

13.2 A

230 V

8.0 A

8.0 A

8.0 A

8.0 A

 

 

 

 

 

Normal mode

7.24 kWh/wk

7.932 kWh/wk

9.188 kWh/wk

9.462 kWh/wk

 

 

 

 

 

Eco mode

5.314 kWh/wk

5.933 kWh/wk

6.566 kWh/wk

6.913 kWh/wk

 

 

 

 

 

Off

0.35 W

0.35 W

0.35 W

0.35 W

 

 

 

 

 

Image 19
Contents Technical Reference C950, X950de, X952de, X952dte, X954de, X954dheEdition notice Contents Index 102 Understanding letters after model numbers IntroductionIntroduction Finding information about the printer Learning about the printerOther countries and regions -See the printed Printable areas Printer Control Language PCL page formattingPaper Supported paper and envelope dimensionsEnvelope Printer Job Language PJL PJL commands informationSupported paper sizes PostScript PS emulationPostScript paper tray support Tray selected with tray operators PostScript envelope size supportEnvelope sizes supported PostScript envelope tray supportEnvelopetray operator selections Airflow requirement Printer specificationsNoise emission levels Power requirements Electrical specificationsClearance requirements Physical specificationsLexmark X95x Series Environmental conditionsAltitude specifications Altitude and atmospheric pressure specificationsAppendix a PCL support PCL emulation commandsSet Page Size Select Symbol Set Appendix a PCL support End Raster Graphics Version B GL/2 commands Appendix a PCL support Appendix a PCL support Appendix a PCL support Common variables for both printer languages Appendix B PJL supportAppendix B PJL support Lexmark‑unique PJL variables for both printer languages Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Common variables for PCL emulation Printer‑unique variables for PCL emulation Printer‑unique Lresource variables Status Readback commandsCommon variables for PostScript emulation Printer‑unique variables for PostScript emulationPJL messages for auto-continuable conditions Ustatus unsolicited status variablesMemory to collate Standard USB Unformatted Priming Failed Too many bins PJL messages for attendance conditions Cmyk * Print Close door or Invalid Tray x Size Check Finisher Replace Oil Appendix B PJL support Stmsg message Close Duplex Xx cyan Module life Cartridge part Yellow 84.41 Cyan PJL messages for paper handling Size Manual Load src with Appendix B PJL support PJL messages for paper jams Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Lexmark‑unique PJL commands Service errorsDevice attendance messages File and device protection commands Supplemental operators Appendix C PostScript supportAppendix C PostScript support Appendix C PostScript support Device parameters Appendix C PostScript support Appendix C PostScript support Appendix C PostScript support User interpreter parameters System interpreter parameters Appendix C PostScript support Appendix C PostScript support Devices supported LPRA% LPRB% LPRC% LPRD% USBA% USBB% USBC% USBD% Appendix C PostScript support PCLSmartSwitch PortLocation PSSmartSwitch Type Appendix C PostScript support DelayedOutputClose Enabled Filtering HasNames Interpreter PortLocation Type Appendix C PostScript support Device Parameters for the Parameters Device %flash1% Appendix C PostScript support 100 PostScript message keys commands Lresource Index