Lexmark 954DHE, 952DE, 950DE, 954DE, 952DTE manual Cmyk * Print

Page 53

Appendix B: PJL support

 

 

 

53

 

 

 

 

 

 

 

 

= Supported

 

 

 

 

 

 

X = Not supported

 

 

 

Printer model

 

 

 

 

 

 

 

 

Message

Status code

Return string

C950

 

X950, X952, X954

 

Intervention Required -

40010

30 CMYK* Print

X

 

X

 

30 CMYK* Print Unit

 

Unit Missing

 

 

 

 

Missing

 

 

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40010

30 Coating Roll

X

 

X

 

30 Coating Roll Missing

 

Missing

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40019

Remove

X

 

X

 

Remove Originals from

 

originals from

 

 

 

 

Scanner ADF

 

the scanner

 

 

 

 

 

 

automatic

 

 

 

 

 

 

document feeder

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40019

Remove paper

 

 

 

 

Remove Paper Standard

 

from standard

 

 

 

 

Bin

 

output bin

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40020

Install MICR

X

 

X

 

Install MICR cartridge

 

cartridge

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Cartridge Life

X

 

X

 

Cartridge Life Expired

 

Expired CMYK*

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Cartridge Life

X

 

X

 

Cartridge Life Warning

 

Warning CMYK*

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Change

X

 

X

 

Change Cartridge Invalid

 

Cartridge

 

 

 

 

Refill

 

Invalid Refill

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Close cover <x>

 

 

 

 

Close Cover <x>

 

 

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Close Cover

X

 

X

 

Printer Cover Open

 

 

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Close Cover

X

 

X

 

Close Toner Box Cover

 

 

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Close Deflector

X

 

X

 

Close Deflector G

 

G

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Close Door

 

 

 

 

Close Door

 

 

 

 

 

 

 

 

 

 

 

 

 

Intervention Required -

40021

Close door <x>

 

 

 

 

Close Door <x>

 

 

 

 

 

 

 

 

 

 

 

 

*This message contains a subset of letters CMYK, where CMYK denotes Cyan, Magenta, Yellow, and Black cartridges, respectively.

Image 53
Contents Technical Reference C950, X950de, X952de, X952dte, X954de, X954dheEdition notice Contents Index 102 Understanding letters after model numbers IntroductionIntroduction Finding information about the printer Learning about the printerOther countries and regions -See the printed Printable areas Printer Control Language PCL page formattingPaper Supported paper and envelope dimensionsEnvelope Printer Job Language PJL PJL commands informationSupported paper sizes PostScript PS emulationPostScript paper tray support Tray selected with tray operators PostScript envelope size supportEnvelope sizes supported PostScript envelope tray supportEnvelopetray operator selections Noise emission levels Printer specificationsAirflow requirement Power requirements Electrical specificationsClearance requirements Physical specificationsLexmark X95x Series Environmental conditionsAltitude specifications Altitude and atmospheric pressure specificationsAppendix a PCL support PCL emulation commandsSet Page Size Select Symbol Set Appendix a PCL support End Raster Graphics Version B GL/2 commands Appendix a PCL support Appendix a PCL support Appendix a PCL support Common variables for both printer languages Appendix B PJL supportAppendix B PJL support Lexmark‑unique PJL variables for both printer languages Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Common variables for PCL emulation Printer‑unique variables for PCL emulation Common variables for PostScript emulation Status Readback commandsPrinter‑unique variables for PostScript emulation Printer‑unique Lresource variablesPJL messages for auto-continuable conditions Ustatus unsolicited status variablesMemory to collate Standard USB Unformatted Priming Failed Too many bins PJL messages for attendance conditions Cmyk * Print Close door or Invalid Tray x Size Check Finisher Replace Oil Appendix B PJL support Stmsg message Close Duplex Xx cyan Module life Cartridge part Yellow 84.41 Cyan PJL messages for paper handling Size Manual Load src with Appendix B PJL support PJL messages for paper jams Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Appendix B PJL support Device attendance messages Service errorsLexmark‑unique PJL commands File and device protection commands Supplemental operators Appendix C PostScript supportAppendix C PostScript support Appendix C PostScript support Device parameters Appendix C PostScript support Appendix C PostScript support Appendix C PostScript support User interpreter parameters System interpreter parameters Appendix C PostScript support Appendix C PostScript support Devices supported LPRA% LPRB% LPRC% LPRD% USBA% USBB% USBC% USBD% Appendix C PostScript support PCLSmartSwitch PortLocation PSSmartSwitch Type Appendix C PostScript support DelayedOutputClose Enabled Filtering HasNames Interpreter PortLocation Type Appendix C PostScript support Device Parameters for the Parameters Device %flash1% Appendix C PostScript support 100 PostScript message keys commands Lresource Index