Emerson 4620 manual String

Page 45

List of Supported Example Applications

 

Example Applications

 

 

 

 

 

-s

STRING

 

 

write string STRING to User Info Area

-f FILE

 

 

write content of file FILE to User Info Area

-w

FILE

 

 

write User Info Area to file FILE

-V

 

 

 

print version information and exit

-h

 

 

 

display this help and exit

#------------------------------

 

 

#

# hpiipmb0

 

 

#

#------------------------------

 

 

Usage: hpiipmb0 [OPTION]

...

the IPMB-A or IPMB-B state control.

HPI example application to set

Options:

use domain with id DOMAIN_ID

-d

DOMAIN_ID

-D

RESOURCE_ID

walk recursivly through the DRT

-r

use resource

with id RESOURCE_ID

-a

{01}

isolate/join

IPMB-A

-b

{01}

isolate/join

IPMB-B

-l

LINK_NUM

use link number LINK_NUM when isolating the IPMB

-V

 

print version information and exit

-h

 

print this help and exit

#------------------------------

 

 

#

# hpiipmi

 

 

#

#------------------------------

 

 

Usage: hpiipmi [OPTION]...

LUN

NETFN CMD [DATA]

HPI example application to send native IPMI commands using the Motorola/Emerson

specific IPMI control.

 

 

LUN,

NETFN, CMD and DATA will be interpreted as hexadecimal values

Options:

use domain with id DOMAIN_ID

-d

DOMAIN_ID

-r

RESOURCE_ID

use resource

with id RESOURCE_ID

-V

 

print version information and exit

-h

 

display this

help and exit

Example:

Send GetDeviceId command (Lun=0, Netfn=6, Cmd=1) to resource 43 on domain 1: hpiipmi -d 1 -r 43 0 6 1

#------------------------------

#

 

#------------------------------hpiled

#

 

#

 

Usage: hpiled [OPTION]...

 

HPI example application to control the LEDs.

 

Options:

use domain with id DOMAIN_ID

 

-d DOMAIN_ID

 

-r RESOURCE_ID

use resource with id RESOURCE_ID

 

-n CONTROL_ID

use control with id CONTROL_ID for set operations

 

-a

set control mode to auto

 

-1 RATE

set led on duration rate in 1/100sec [0-255]

 

-0 RATE

set led off duration rate in 1/100sec [0-255]

 

-t RATE

led test

 

-V

print version information and exit

 

-h

display this help and exit

 

 

 

System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)

45

Image 45
Contents System Management Interface Based on HPI-B Centellis Contact Address Contents Related Documentation ContentsDefinition of Domain Management Resource List of TablesPage List of Figures Page Overview of Contents About this ManualAbbreviations About this Manual Abbreviation Description ConventionsNotation Description BoldSummary of Changes Comments and SuggestionsAbout this Manual Notation Description Page Introduction System Management Interfaces OverviewStandard Compliances ArchitectureSystem Management Interfaces Overview HPI Library HPI LibraryHigh Availability HPI DaemonHPI Daemon Page Installing and Configuring the HPI-B Daemon Software Installation and ConfigurationOverview RPM Files for HPI-B Clients and DaemonsConfiguring an HPI Daemon Installing an HPI-B DaemonOverview of HPI-B Directories and Files on ATCA-F120 Directory DescriptionSetting Up HPI Clients Installing HPI ClientsOverview of HPI-B Directories and Files on Node Blades Multishelf Library Configuration File HPI Daemon Entries Configuring HPI ClientsIP Addresses/Ports of HPI Daemons in a Centellis 4620 Shelf Entry DescriptionDeveloping Applications Directory ContentBuilding the Application Development RPMs Directory StructurePage Using HPI-B Limitations with Respect to HPI-B Base SpecificationLimitations Overview Working with the Multishelf LibraryAccessing HPI Domains Using HPI-B Accessing HPI DomainsHow Domains and Shelves are Represented Using HPI-B How Domains and Shelves are RepresentedHow Domains and Shelves are Represented Using HPI-B Domain Management Control RDR Definition of Domain Management ResourceSaHpiRptEntryT Value SaHpiRdrT ValueDomain Management Control Domain Management Control StateShelf Management Resource Connection State RDR Using HPI-BHow Domains and Shelves are RepresentedDomain Connection Sensor Discovering Shelves and DomainsDomain Connection Sensor Reading Domain Connection Sensor EventsUsing HPI-B Adding and Removing Shelves and Domains Adding and Removing Shelves and DomainsParameter Value Emerson Extensions Emerson Extensions Using HPI-B10 Boot Option RDR Ipmi System Boot Options Support11 Boot Option Control Using HPI-B HPI Controls for Domain and Shelf ManagementIpmi System Boot Options SupportUsing HPI-B 12 Boot Option StateGet operations Set operationsHPI Logging Support Post Type Control13 Post Type HPI Control RDR 14 Post Type HPI Control Sate ValuesHPI Logging Support Using HPI-B 15 Log RDR16 Log Control 17 Log Control State Using HPI-BHPI Logging SupportExample Applications Example Application Source FilesList of Supported Example Applications Example Applications List of Supported Example Applications List of Supported Example ApplicationsExample Applications Display everything #------------------------------hpifumi #------------------------------ hpihotswap String Example Applications List of Supported Example Applications Option #------------------------------ hpishelf Value Display sensors Related Specifications Emerson Network Power Embedded Computing DocumentsTable B-2 Related Specifications Related Documentation