Emerson 4620 manual List of Figures

Page 7

List of Figures

Figure 1-1 Overview of HPI Usage in Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Figure 4-1 Multishelf Library - Representation of Shelves as Domains . . . . . . . . . . . . . . . . . . . . . 25 Figure 4-2 HPI Multishelf Library - Overview of Related HPI Resources and Controls . . . . . . . . . 27

System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)

7

Image 7
Contents System Management Interface Based on HPI-B Centellis Contact Address Contents Related Documentation ContentsDefinition of Domain Management Resource List of TablesPage List of Figures Page About this Manual Overview of ContentsAbbreviations Bold ConventionsAbout this Manual Abbreviation Description Notation DescriptionComments and Suggestions Summary of ChangesAbout this Manual Notation Description Page Architecture System Management Interfaces OverviewIntroduction Standard CompliancesSystem Management Interfaces Overview HPI Library HPI LibraryHPI Daemon High AvailabilityHPI Daemon Page RPM Files for HPI-B Clients and Daemons Software Installation and ConfigurationInstalling and Configuring the HPI-B Daemon OverviewDirectory Description Installing an HPI-B DaemonConfiguring an HPI Daemon Overview of HPI-B Directories and Files on ATCA-F120Installing HPI Clients Setting Up HPI ClientsOverview of HPI-B Directories and Files on Node Blades Entry Description Configuring HPI ClientsMultishelf Library Configuration File HPI Daemon Entries IP Addresses/Ports of HPI Daemons in a Centellis 4620 ShelfDevelopment RPMs Directory Structure Directory ContentDeveloping Applications Building the ApplicationPage Limitations with Respect to HPI-B Base Specification Using HPI-BLimitations Overview Working with the Multishelf LibraryAccessing HPI Domains Using HPI-B Accessing HPI DomainsHow Domains and Shelves are Represented Using HPI-B How Domains and Shelves are RepresentedHow Domains and Shelves are Represented Using HPI-B SaHpiRdrT Value Definition of Domain Management ResourceDomain Management Control RDR SaHpiRptEntryT ValueDomain Management Control State Domain Management ControlShelf Management Resource Connection State RDR Using HPI-BHow Domains and Shelves are RepresentedDomain Connection Sensor Events Discovering Shelves and DomainsDomain Connection Sensor Domain Connection Sensor ReadingAdding and Removing Shelves and Domains Using HPI-B Adding and Removing Shelves and DomainsParameter Value Emerson Extensions Emerson Extensions Using HPI-BUsing HPI-B HPI Controls for Domain and Shelf Management Ipmi System Boot Options Support10 Boot Option RDR 11 Boot Option ControlSet operations 12 Boot Option StateIpmi System Boot Options SupportUsing HPI-B Get operations14 Post Type HPI Control Sate Values Post Type ControlHPI Logging Support 13 Post Type HPI Control RDR15 Log RDR HPI Logging Support Using HPI-B16 Log Control 17 Log Control State Using HPI-BHPI Logging SupportExample Application Source Files Example ApplicationsList of Supported Example Applications Example Applications List of Supported Example Applications List of Supported Example ApplicationsExample Applications Display everything #------------------------------hpifumi #------------------------------ hpihotswap String Example Applications List of Supported Example Applications Option #------------------------------ hpishelf Value Display sensors Related Documentation Emerson Network Power Embedded Computing DocumentsRelated Specifications Table B-2 Related Specifications