Emerson GXT2U user manual Important Safety Instructions

Page 5

IMPORTANT SAFETY INSTRUCTIONS

! WARNING

Opening or removing the cover may expose you to lethal voltages within this unit even when it is apparently not operating and the input wiring is disconnected from the electrical source. Observe all cautions and warnings in this manual. Failure to do so MAY result in serious injury or death. Refer all UPS and battery service to qualified service personnel. Do not attempt to service this product yourself. Never work alone.

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions. Read all safety, installation, and operating instructions before operating the Uninterruptible Power System (UPS). Adhere to all warnings on the unit and in this manual. Follow all operating and user instructions. Individuals without previous training can install and operate this equipment.

It is not intended for use with life support and other designated “critical” devices. Maximum load must not exceed that shown on the UPS rating label. The UPS is designed for data processing equipment. If uncertain, consult your local dealer or Liebert representative.

This UPS is designed for use on a properly grounded (earthed), 50Hz or 60Hz, 208V supply (programmable for 200, 208, 220, 230, and 240VAC output). Installation instructions and warning notices are located in this manual.

ELECTROMAGNETIC COMPATIBILITY—The Liebert GXT2U™ Series complies with the limits for a CLASS A DIGITAL DEVICE, PURSUANT TO Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Operating this device in a residential area is likely to cause harmful interference that users must correct at their own expense.

Operate the UPS in an indoor environment only in an ambient temperature range of 32°F to +104°F (0°C to +40°C). Install it in a clean environment, free from moisture, flammable liquids, gases and corrosive substances.

This UPS contains no user serviceable parts except the internal battery pack. The UPS ON/Standby push buttons do not electrically isolate internal parts. Under no circumstances attempt to gain access internally other than to replace the batteries due to risk of electric shock or burn. Do not continue to use the UPS if the front panel indications are not in accordance with these operating instructions or if the UPS performance alters in use. Refer all faults to your local dealer, Liebert representative or the Liebert Worldwide Support Group.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from the batteries. PROPER DISPOSAL OF BATTERIES IS REQUIRED. REFER TO YOUR LOCAL LAWS AND REGULATIONS FOR BATTERY DISPOSAL REQUIREMENTS.

Never block or insert any object into the ventilation holes or other openings of the UPS.

1

Image 5
Contents Liebert GXT2U Page Table of Contents Operating Instructions Important Safety Instructions Page Glossary of Symbols Introduction Battery Charger Rectifier/Power Factor Correction PFC CircuitMajor Components Transient Voltage Surge Suppression and EMI/RFI FiltersDynamic Bypass BatteryDC-to-DC Converter Liebert GXT2U-Rear View Tower UPS Installation InstallationPreparation Base to accommodateOptional rack mount handles Rack-Mount UPS Conversion and InstallationM5 screws Mounting railsApply External Battery Cabinet Installation Page ON/Alarm Silence/Manual Battery Test Button Controls and IndicatorsFault Indicator LED Red Load/Battery Level Indicators 4 Green, 1 AmberBypass Indicator LED Amber UPS on Indicator LED GreenOutput Voltage Selection Operating Instructions Normal Mode OperationBypass Mode Operation Battery Recharge Mode Battery Mode OperationCommunications Pins 4 & 5 Remote Shutdown on BatteryCommunications Interface Port Pin Assignment DescriptionAuto-Enable Output Pin 6 Logic Pins 5 & 6 Any-Mode ShutdownUPS Intelligent Communications Liebert GXT2U Configuration Program Abilities Configuration ProgramBattery Replacement MaintenanceInternal Battery Replacement Procedures On bypass due to overtemperature condition beep every 4 sec TroubleshootingOn bypass due to DC bus overvoltage beep every 4 sec On bypass due to PFC failure beep every 4 secProblem Cause Solution Troubleshooting GuideBattery test is performed Condition Alarm Alarm ConditionsSpecifications WEIGHT, lb kg Battery Cabinet SpecificationsDimensions in mm Internal Battery Battery Run TimesLoad % MinutesProduct Warranty Registration Page Page Page Locations Technical Support / ServiceEmerson Network Power