Emerson Remote Monitoring Panel user manual RMP component location in Figure

Page 7

Introduction

Table 1

RMP component location in Figure 1

 

 

 

 

1

Bypass Input

10

F3 Function Key

 

 

 

 

2

Inverter—DC to AC

11

F4 Function Key

3

Rectifier—Input AC to DC

12

Help Key

 

 

 

 

4

Load—AC Output

13

Silence On/Off Audible—Alarm Mute

 

 

 

 

5

Battery—DC Backup

14

RS-232—for firmware update

6

Audible Alarm—Buzzer

15

RS-232—Reserved, not used

 

 

 

 

7

UPS Status and Alarm indicator

16

AC power input cable entry

 

 

 

 

8

F1 Function Key

17

RS-485 communication cable entry

9

F2 Function Key

 

 

 

 

 

 

 

Figure 2 Remote Monitoring Panel layout constraints

UPS Room

Maintenance or Control Room

EMERSON™

Network Power

Communication

Cable; Maxi- mum Length

Liebert NX100m (328ft.) (field-supplied)

Liebert NX

12-16-2009

12:22:14

081 kVA -3x3

Single

Normal

EMERSON

Network Power

Liebert ®

Press any key back to main menu

F1 F2 F3 F4 HELP

L ie b e rt

Remote Monitor Panel

3

Image 7 Contents
Liebert Remote Monitoring Panel Page Table of Contents Figures Information for the Protection of the Environment Introduction RMP component location in Figure UPS Room Maintenance or Control RoomPreliminary checks Power Supply15.6mm 14mm Cable Specifications Communication cable specificationsUPSU2J24 Mounting the RMP on DrywallElectrical connections Power and communication cable routingCommunication connections On Remote Monitoring Panel board RS-485 cable connection to Liebert NXOpening screen Startup and ResetSilence On/Off screens UPS and RMP firmware are compatible screenCommunication with UPS failed Audible Alarms-Buzzer LED Mimic Power FlowMenu key Icons and their meaning LCD Monitor and Menu KeysKey Help Window Type Stop Freshening Charge Freshening ChargeMenu Type Item Type Explanation Detailed Description of Menu ItemsUPS system window Descriptions of RMP menus and data window itemsCurrent Record Window RMP messages Status and Event MessagesMessage Description / Suggested Action if any Condition is no longer true EPO RMP messages Prompt windows, meanings controlled at RMP Dynamic Energy Flow Chart and UPS Help ScreenPrompt Popup Windows Prompt windows, meanings controlled at UPS onlyHelp screen Default screen saverCable specifications Mechanical specificationsEnvironmental specifications Electrical specificationsElectromagnetic interference EMI-emission limits Agency and CertificationsElectromagnetic susceptibility EMS-immunity levels Er t Ne tIti Ti n