Emerson MPR25, MPR15 Series user manual Power shelf, Mechanical

Page 31

31

Power shelf

Mechanical

The power shelf provides housing for plug-in rectifiers and for an optional LVD. The power shelf provides power connections and signal access to the rectifiers.

As listed in Table 4, there are two shelf sizes with the following capacities:

a)19-inch mounting - 2 x MPR25 or MPR15 (Figure 4)

-2 x MPR25 or MPR15 + LVD

-3 x MPR25 or MPR15

b)23-inch mounting - 3 x MPR25 or MPR15 (Figure 5)

-2 x MPR25 or MPR15 + LVD (Figure 7)

-2 x MPR25 or MPR15 + LVD + RPM1000C (Figure 6)

-3 x MPR25 or MPR15 + EQL SW Assembly (Figure 8)

c)There are two main application versions: System

In the system version (Table 4) the rectifier signals are brought out from the shelf through cables terminated with connectors which connect to the power plant's Controller.

The AC input is either common bussed or individually fed, equipped or not, for EMI filtering to the rectifiers.

25A Switch Mode RectifierNT5C06B / C Installation and User Manual

Image 31
Contents NT5C06B/C 25A Switch Mode RectifierPage Part of Emerson Network Power Page Publication history October 1 February 15Contents Contents Inrush current limiting fuse F1 Low voltage disconnect 101105 List of FiguresList of Tables Rectifier AC and DC power internal cabling harnessList of Procedures How this manual is organized Safety precautionsAbout this manual Purpose of this manualThis page is left blank intentionally Applications IntroductionRectifier models Rectifier feature summaryNT5C06B/C models MPR15/MPR25 input current requirements SpecificationsMechanical Electrical Rectifier voltage and currentOutput noise and ripple Output voltageHeat dissipation Efficiency and power factorAcoustical noise ReliabilityStorage TransportationRectifier operation OperationDisplay and rear interface Indicator lampsLocal float / equalize control Local ON/OFF control DC and optional AC breakers Rectifier failure alarm RFAFan failure alarm Internal high voltage shut down HvsdFan filter option Fan cooling assemblyTest points V+ Current meterOperating features Remote voltage sensing Signal connectorPower interface edge connector FeaturesParallel operation Monitoring features Input AC voltage monitorAC inrush current Sequential startRemote high voltage shutdown Measurement features Remote rectifier current measurementControl features Remote ON/OFF control Output current monitorSignal connections Local/remote high voltage shutdown resetRemote equalize control Signal Connector Rectifier and controller interface connections Designation Description SignalPower shelf Features MPS75S MPS75E MPS50S MPS50E Power Shelf Feature SummaryPEC Code Color Modular power shelf embedded application signal availabilityWhen used with an RPM1000C, order P0736447 Modular power shelf system application signal availability List of abbreviations used in Tables 6 19-inch power shelf front view23-inch power shelf front view Electrical Power shelf NT5C10BM e/w EQL switch assemblyOutput current One rectifier Environmental Installation procedure Installation and start-up proceduresTools and test equipment 19-inch power shelf 19-inch power shelf NT5C10BF and NT5C10BP only Cabling the power shelfInch embedded shelf NT5C10BA-3/4 Shelf configuration Inch system shelf NT5C10CA-1/2Inch embedded shelf NT5C10BF-1 and NT5C10BP Inch embedded shelf NT5C10BA-1/2Inch embedded shelf NT5C10BB-1/2 Inch embedded shelf NT5C10BA-5/6,NT5C10BB-3/4Inch embedded shelf NT5C10BC-1/2 Inch embedded shelf NT5C10BJ, NT5C10BK Inch embedded shelf NT5C10BC-3, NT5C10BD-3Inch embedded shelf NT5C10BM Inch embedded shelf NT5C10BLInch system shelf NT5C10CO Procedure 2 Common bussed AC connection side access StepP0711722 Procedure 4 Individual AC connection-side access Step Embedded shelf left view Individual AC side accessProcedure 5 Individual AC connection side access Step System or embedded shelf left view individual AC side accessInstallation and start-up procedures Procedure 7 DC connection side access Step Procedure 8 DC connection rear access Step Power plant interface signal cablingDesignation Description Signal Standard system application signal cable connectionsNT5C10BJ & NT5C10BK NT5C10BA-3/4 special operating signal AC fail NCNT5C10BM Installing the rectifier Operating voltage Cabling the rectifierLVD installation in the shelf Embedded shelf LVD connections side access Start-up procedure Factory set voltage limitsProcedure 11 Rectifier power-up Step Rectifier power-upFloat voltage on the test points Hvsd adjustmentRe-adjust if needed return to step Desired Hvsd levelProcedure 14 Equalize voltage adjustment Step Float voltage adjustmentEqualize voltage adjustment Procedure 13 Float voltage adjustment StepParallel verification Low voltage disconnect LVD Procedure 16 Low voltage disconnect adjustment Step Action Adjustment for the 50 a LVD unit Rel , 02A, 3 & 3ALVD/low voltage disconnect / reconnect Lvdr adjustment Low voltage alarm LVA adjustmentProcedure 18 Low voltage alarm adjustment Step Rectifier replacement/add-on procedure Low voltage disconnect DC cabling Control and monitoring signalsOperation Test featureThis page is left blank intentionally Maintenance Rectifier MaintenanceProcedure 20 Float/equalize and remote equalize Step Action Filter Power shelfFan cooling Low voltage disconnect Troubleshooting Rectifier fail alarmProcedure 21 Fan replacement Step Fan replacement procedureFan failure End Fan assembly Symptom Possible cause Fault diagnosisThis page is left blank intentionally References System application power shelf MPS50S and MPS75SEmbedded application power shelf MPS50E and MPS75E Low voltage disconnect System application Dolphin grey Embedded application Oxford greyEmbedded application Brown System application BrownNT5C10BA-5/6 and NT5C10BB-1/2, 3/4 embedded application NT5C10BA-1/2 embedded application NT5C10BA-3/4 embedded application NT5C10BD embedded application NT5C10BD and NT5C10BP embedded application To First References RPM Unit JE1 To RFA COM of Office Alarm Circuit JE2 JE1 PE1 P0711722 To -48VDC Output Embedded application NT5C10BL Embedded application NT5C10BM e/w NT5C10KB System application NT5C10CO Application NT5C06B/C This page is left blank intentionally Ftip application Appendix a NT5C10BF-1 and NT5C10BPPurpose ApplicationPower and signal lead termination AlarmsFactory set voltage limits Ftop application Main/standby Application configuration table Rectifier FunctionShelf labeling General requirements Power shelf size105 NT5C10CO power shelf DescriptionAppendix B NT5C10CO shelf GeneralTechnical specifications Procedure 22 Power-up and verification Step Action Power-up and verification VerificationProcedure 23 Adjustment and verification Step Adjustment and verificationPosition is lit Procedure 23 Adjustment and verification Step ActionOpen Closed Systems equipped with NT5C10CO power shelf fault diagnosis TroubleshootingThis page is left blank intentionally 113 Appendix C Recommended replacement partsAppendix C Recommended replacement parts Country Appendix D Technical service assistanceLocal toll-free prefixes 115United States Canada Europe Asia and the Pacific Toll-free technical assistance numbers117 Abbreviations and acronymsAbbreviations and acronyms Page 25A Switch Mode Rectifier

MPR15 Series, MPR25 specifications

The Emerson MPR25 and MPR15 series are advanced pressure regulators designed for precise control and performance in various industrial applications. Known for their durability and reliability, these regulators are ideal for both gas and liquid control systems, ensuring consistent operation across a wide range of conditions.

One of the main features of the MPR series is its innovative design that utilizes a robust diaphragm mechanism. This mechanism provides a high degree of sensitivity and response time, allowing for quick adjustments and ensuring accurate pressure regulation. The regulators are available in different pressure ranges, making them versatile for various processes and systems.

The MPR25 series typically caters to applications requiring higher flow capacities. It boasts an extensive flow capacity with less pressure drop, making it suitable for demanding environments where maintaining system efficiency is crucial. This series is often used in applications such as gas distribution systems, instrumentation, and chemical processing.

On the other hand, the MPR15 series is designed for lower flow applications, providing precise pressure control in compact spaces. Despite its smaller size, it maintains excellent performance, featuring low droop characteristics that allow for consistent pressure output even with varying flow rates.

Both series incorporate advanced materials and sealing technologies to enhance their durability and resistance to harsh operating conditions. The body is commonly made from high-grade materials that ensure resistance to corrosion, allowing for longer service life and reduced maintenance needs. Additionally, the regulators feature easy-to-adjust set points, enabling operators to quickly adapt to changing process requirements.

Furthermore, the MPR25 and MPR15 series regulators are designed with safety in mind. They include built-in safety features to prevent over-pressurization, enhancing system protection and operator safety. The design also allows for easy installation and servicing, contributing to lower operational costs over time.

In summary, the Emerson MPR25 and MPR15 series pressure regulators stand out for their precision, durability, and efficiency. With their advanced diaphragm mechanism, robust construction, and user-friendly features, they meet the needs of a diverse range of industrial applications, ensuring reliable operation in every environment. Whether for high-demand or compact applications, these regulators are an excellent choice for maintaining the integrity and performance of pressure control systems.