Emerson MPR25, MPR15 Series user manual JE1 PE1

Page 93

References 93

Figure 40 - Embedded application NT5C10BJ, NT5C10BK e/w RPM1000C and LVD Kit

TO -48VDC OUTPUT

 

 

 

CA ASSY

 

 

NT6C19AA OR BA

 

 

 

 

 

 

 

 

 

PART OF KIT

 

 

 

 

 

 

 

 

 

 

 

P0736447

 

 

RPM1000C UNIT

 

 

 

 

 

 

 

 

 

 

 

P5

(PROVIDED PER MS5C10)

 

 

 

 

 

 

 

 

 

 

 

J5

 

 

 

 

 

 

 

 

 

 

 

-48V

1

 

JE1

PE1

 

 

 

P0736442

 

 

 

 

 

-48V

2

 

EQL

P0736441

 

 

 

 

 

 

BR

3

 

1

 

 

CA ASSY

 

 

 

 

 

 

 

 

RG+

CA ASSY

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

P1

 

 

RC-

 

 

 

 

 

 

 

 

-48V

J1

3

 

 

 

 

 

NT6C13FJ OR FK

 

 

1

 

4

 

FAN ALM (NC)

 

 

 

 

LOW VOLTAGE DISCONNECT

 

 

BR

2

 

5

 

HVSDR

 

 

 

 

(PROVIDED PER MS5C10)

TO HALL SENSORS

BAT CUR

 

3

 

6

 

HVSD

 

 

(2) 10AWG

-48V

 

 

OR TRANSDUCER

BAT CUR

 

4

 

7

 

RFA (NC)

 

 

 

 

 

BAT CUR

 

 

 

TR

 

 

 

 

(K1)

 

 

5

 

8

 

 

 

 

 

 

LOAD CUR

 

 

 

 

 

 

TO LOADS 0

 

CNTOR

TO HALL SENSORS

 

6

 

 

 

 

 

 

 

LOAD CUR

 

 

 

 

 

 

 

 

 

 

 

7

 

JE2

PE2

 

 

 

AS REQ'D

 

 

 

OR TRANSDUCER

LOAD CUR

 

 

EQL

 

 

 

 

NT6C14PA

 

 

8

 

1

 

 

 

 

 

 

 

 

 

 

RG+

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

CKT PACK

 

 

 

 

 

 

RC-

 

 

 

 

 

 

 

P2

J2

3

 

 

 

 

 

 

 

 

AC VOLT

 

 

 

 

 

 

TB1

 

CONN AS

 

 

FAN ALM (NC)

 

 

 

-48V

 

 

1

 

4

 

 

 

 

1

-48V

REQUIRED

AC VOLT

 

2

 

5

 

HVSDR

 

 

 

BR

CONN AS

TEMP+

 

 

 

HVSD

 

 

 

2

BR

 

3

 

6

 

 

 

 

LVD CTL

TEMP-

 

 

 

RFA (NC)

RFA1

 

 

3

LVD CTR

REQUIRED

 

4

 

7

 

TO OFFICE

 

LVD/FA

 

 

 

FA BATT

 

TR

 

 

4

(NC)

 

 

NC

5

8

 

 

 

BR

 

 

 

 

RFA2

ALARM CIRCUIT

 

5

(C)

 

MAJ RFA

NC

6

 

 

 

 

AS REQUIRED

 

CA ASSY

6

(NO)

CONN AS

 

7

 

 

 

 

 

 

 

PART OF KIT

7

FA OUT

REQUIRED

MIN RFA

 

8

 

 

 

 

 

 

 

P0736447

 

 

 

JE7

PE7

 

 

 

 

 

8

FA IN

 

 

 

 

 

HVSD

 

 

 

 

9

LVD (CB)

 

 

FA GRD

P3

J3

1

 

 

 

 

 

 

 

 

RESTART

 

 

 

 

 

 

2

 

 

 

 

 

10 LVD CNTOR

 

EVENT 2

 

1

 

 

MAJ (C)

 

 

 

 

11 LVD CNTOR

 

 

2

 

3

 

TO OFFICE

 

 

 

CONN AS

EVENT 3

 

 

 

MAJ (NO)

 

 

 

 

 

 

3

 

4

 

ALARM CIRCUIT

 

 

 

 

 

REQUIRED

EVENT 4

 

4

 

5

 

MAJ (NC)

AS REQUIRED

 

 

 

 

 

 

EVENT 5

 

5

 

6

 

MIN (C)

 

 

 

 

 

 

 

EVENT 6

 

 

 

MIN (NO)

 

 

 

 

 

 

 

 

6

 

7

 

 

 

 

 

 

 

 

EVENT 7

 

 

 

MIN (NC)

 

 

 

 

 

 

 

 

7

 

8

 

 

 

 

 

 

 

 

EVENT 8

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCD

 

 

 

 

 

 

 

COM EVENT/REL

 

P4

J4

1

 

 

 

 

 

 

 

 

 

 

RXD

 

 

 

 

 

 

 

 

1

 

2

 

 

 

 

 

 

 

TO OFFICE

FA OUT

 

 

 

TXD

 

 

 

 

 

 

 

2

 

3

 

 

 

 

 

 

 

ALARM CIRCUIT

EQL

 

 

 

DTR

CONN AS

 

 

 

 

 

 

3

 

4

 

 

 

 

 

 

AS REQUIRED

 

LVD CTL

 

 

SG

REQUIRED

 

 

 

 

 

 

OUT 1 ALL MIN

4

 

5

 

 

 

 

 

 

 

 

 

 

 

DSR

 

 

 

 

 

 

 

OUT 2 ALL MAJ

 

5

 

6

 

 

 

 

 

 

 

 

 

 

 

RTS

 

 

 

 

 

 

 

 

6

 

7

 

 

 

 

 

 

 

TO DMS1-U

OUT 3

 

 

 

CTS

 

 

 

 

 

 

 

7

 

8

 

 

 

 

 

 

 

CABINET ALARM

UNIT FAIL MAJ ALM

 

 

 

SPARE

 

 

 

 

 

 

 

8

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEL

 

TEL LINE

CONN AS

 

 

 

 

 

 

 

 

 

 

LINE

 

 

REQUIRED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25A Switch Mode RectifierNT5C06B / C Installation and User Manual

Image 93
Contents NT5C06B/C 25A Switch Mode RectifierPage Part of Emerson Network Power Page Publication history October 1 February 15Contents Contents Inrush current limiting fuse F1 Low voltage disconnect 101105 List of FiguresList of Tables Rectifier AC and DC power internal cabling harnessList of Procedures About this manual Safety precautionsPurpose of this manual How this manual is organizedThis page is left blank intentionally Applications IntroductionRectifier feature summary Rectifier modelsNT5C06B/C models Mechanical SpecificationsElectrical Rectifier voltage and current MPR15/MPR25 input current requirementsOutput noise and ripple Output voltageAcoustical noise Efficiency and power factorReliability Heat dissipationStorage TransportationRectifier operation OperationIndicator lamps Display and rear interfaceLocal float / equalize control Fan failure alarm Rectifier failure alarm RFAInternal high voltage shut down Hvsd Local ON/OFF control DC and optional AC breakersTest points V+ Fan cooling assemblyCurrent meter Fan filter optionPower interface edge connector Signal connectorFeatures Operating features Remote voltage sensingAC inrush current Monitoring features Input AC voltage monitorSequential start Parallel operationControl features Remote ON/OFF control Measurement features Remote rectifier current measurementOutput current monitor Remote high voltage shutdownLocal/remote high voltage shutdown reset Signal connectionsRemote equalize control Signal Connector Rectifier and controller interface connections Designation Description SignalPower shelf Features MPS75S MPS75E MPS50S MPS50E Power Shelf Feature SummaryPEC Code Color Modular power shelf embedded application signal availabilityWhen used with an RPM1000C, order P0736447 Modular power shelf system application signal availability List of abbreviations used in Tables 6 19-inch power shelf front view23-inch power shelf front view Electrical Power shelf NT5C10BM e/w EQL switch assemblyOutput current One rectifier Environmental Installation and start-up procedures Installation procedureTools and test equipment 19-inch power shelf 19-inch power shelf NT5C10BF and NT5C10BP only Cabling the power shelfInch embedded shelf NT5C10BF-1 and NT5C10BP Shelf configuration Inch system shelf NT5C10CA-1/2Inch embedded shelf NT5C10BA-1/2 Inch embedded shelf NT5C10BA-3/4Inch embedded shelf NT5C10BA-5/6,NT5C10BB-3/4 Inch embedded shelf NT5C10BB-1/2Inch embedded shelf NT5C10BC-1/2 Inch embedded shelf NT5C10BM Inch embedded shelf NT5C10BC-3, NT5C10BD-3Inch embedded shelf NT5C10BL Inch embedded shelf NT5C10BJ, NT5C10BKInch system shelf NT5C10CO Procedure 2 Common bussed AC connection side access StepP0711722 Procedure 4 Individual AC connection-side access Step Embedded shelf left view Individual AC side accessProcedure 5 Individual AC connection side access Step System or embedded shelf left view individual AC side accessInstallation and start-up procedures Procedure 7 DC connection side access Step Procedure 8 DC connection rear access Step Power plant interface signal cablingDesignation Description Signal Standard system application signal cable connectionsNT5C10BJ & NT5C10BK NT5C10BA-3/4 special operating signal AC fail NCNT5C10BM Installing the rectifier Operating voltage Cabling the rectifierLVD installation in the shelf Embedded shelf LVD connections side access Start-up procedure Factory set voltage limitsProcedure 11 Rectifier power-up Step Rectifier power-upRe-adjust if needed return to step Hvsd adjustmentDesired Hvsd level Float voltage on the test pointsEqualize voltage adjustment Float voltage adjustmentProcedure 13 Float voltage adjustment Step Procedure 14 Equalize voltage adjustment StepParallel verification Low voltage disconnect LVD Procedure 16 Low voltage disconnect adjustment Step Action Adjustment for the 50 a LVD unit Rel , 02A, 3 & 3ALow voltage alarm LVA adjustment LVD/low voltage disconnect / reconnect Lvdr adjustmentProcedure 18 Low voltage alarm adjustment Step Rectifier replacement/add-on procedure Low voltage disconnect DC cabling Control and monitoring signalsOperation Test featureThis page is left blank intentionally Maintenance Maintenance RectifierProcedure 20 Float/equalize and remote equalize Step Action Power shelf FilterFan cooling Low voltage disconnect Troubleshooting Rectifier fail alarmFan replacement procedure Procedure 21 Fan replacement StepFan failure End Fan assembly Symptom Possible cause Fault diagnosisThis page is left blank intentionally References System application power shelf MPS50S and MPS75SEmbedded application power shelf MPS50E and MPS75E Low voltage disconnect Embedded application Brown Embedded application Oxford greySystem application Brown System application Dolphin greyNT5C10BA-5/6 and NT5C10BB-1/2, 3/4 embedded application NT5C10BA-1/2 embedded application NT5C10BA-3/4 embedded application NT5C10BD embedded application NT5C10BD and NT5C10BP embedded application To First References RPM Unit JE1 To RFA COM of Office Alarm Circuit JE2 JE1 PE1 P0711722 To -48VDC Output Embedded application NT5C10BL Embedded application NT5C10BM e/w NT5C10KB System application NT5C10CO Application NT5C06B/C This page is left blank intentionally Purpose Appendix a NT5C10BF-1 and NT5C10BPApplication Ftip applicationAlarms Power and signal lead terminationFactory set voltage limits Ftop application Main/standby Application configuration table Rectifier FunctionShelf labeling General requirements Power shelf sizeAppendix B NT5C10CO shelf NT5C10CO power shelf DescriptionGeneral 105Technical specifications Procedure 22 Power-up and verification Step Action Power-up and verification VerificationProcedure 23 Adjustment and verification Step Adjustment and verificationPosition is lit Procedure 23 Adjustment and verification Step ActionOpen Closed Systems equipped with NT5C10CO power shelf fault diagnosis TroubleshootingThis page is left blank intentionally 113 Appendix C Recommended replacement partsAppendix C Recommended replacement parts Local toll-free prefixes Appendix D Technical service assistance115 CountryUnited States Canada Europe Asia and the Pacific Toll-free technical assistance numbers117 Abbreviations and acronymsAbbreviations and acronyms Page 25A Switch Mode Rectifier

MPR15 Series, MPR25 specifications

The Emerson MPR25 and MPR15 series are advanced pressure regulators designed for precise control and performance in various industrial applications. Known for their durability and reliability, these regulators are ideal for both gas and liquid control systems, ensuring consistent operation across a wide range of conditions.

One of the main features of the MPR series is its innovative design that utilizes a robust diaphragm mechanism. This mechanism provides a high degree of sensitivity and response time, allowing for quick adjustments and ensuring accurate pressure regulation. The regulators are available in different pressure ranges, making them versatile for various processes and systems.

The MPR25 series typically caters to applications requiring higher flow capacities. It boasts an extensive flow capacity with less pressure drop, making it suitable for demanding environments where maintaining system efficiency is crucial. This series is often used in applications such as gas distribution systems, instrumentation, and chemical processing.

On the other hand, the MPR15 series is designed for lower flow applications, providing precise pressure control in compact spaces. Despite its smaller size, it maintains excellent performance, featuring low droop characteristics that allow for consistent pressure output even with varying flow rates.

Both series incorporate advanced materials and sealing technologies to enhance their durability and resistance to harsh operating conditions. The body is commonly made from high-grade materials that ensure resistance to corrosion, allowing for longer service life and reduced maintenance needs. Additionally, the regulators feature easy-to-adjust set points, enabling operators to quickly adapt to changing process requirements.

Furthermore, the MPR25 and MPR15 series regulators are designed with safety in mind. They include built-in safety features to prevent over-pressurization, enhancing system protection and operator safety. The design also allows for easy installation and servicing, contributing to lower operational costs over time.

In summary, the Emerson MPR25 and MPR15 series pressure regulators stand out for their precision, durability, and efficiency. With their advanced diaphragm mechanism, robust construction, and user-friendly features, they meet the needs of a diverse range of industrial applications, ensuring reliable operation in every environment. Whether for high-demand or compact applications, these regulators are an excellent choice for maintaining the integrity and performance of pressure control systems.