Philips Kvaser LAPcan II manual Technical data, Kvaser LAPcan and Kvaser LAPcan

Page 7

Kvaser LAPcan / LAPcan II Hardware Guide

7(19)

 

 

5 Technical data, Kvaser LAPcan and Kvaser LAPcan II

CAN channels

2 (CAN 2.0A and 2.0B active)

 

 

CAN Transceivers

The transceivers are integrated into the DRVcans.

 

 

CAN Controllers

Philips SJA 1000

 

 

Microcontroller

Siemens SAB-C161O (16 MHz)

 

 

Baudrate

5 kbit/s ... 1 Mbit/s

 

 

Timestamp resolution

8 s

 

 

Error Frame Detection

Yes, both channels

 

 

Error Frame Generation

Yes, both channels

 

 

Hardware requirements

IBM PC AT or 100% compatible; PC-Card slot type II

 

or III

PC interface

PC-Card Version 2.0 (PCMCIA) or compatible

 

 

Current consumption

110 mA for the Kvaser LAPcan plus the current of the

 

DRVcans

Software requirements

Windows 95 / Windows NT 4.0 or later

 

 

Configuration

Done by software (Plug & Play if OS supports it.)

 

 

Dimensions

PC-Card type II (ca. 85 mm x 64 mm x 5 mm)

 

 

Operating temperature

0 ºC ... +55 ºC

 

 

Non-operating

-25 ºC ... +70 ºC

temperature

 

Relative Humidity

0% ... 85% (non condensing.)

 

 

Kvaser AB, Mölndal, Sweden — www.kvaser.com

Image 7
Contents Kvaser LAPcan / LAPcan II Hardware Guide Kvaser LAPcan / LAPcan II Hardware Guide 219 Table of Contents About this manual Introduction Kvaser LAPcan installation Technical data, Kvaser LAPcan and Kvaser LAPcan Typical DRVcan DRVcansName DRVcan TypesHow to use the DRVcan Few Words of Caution D-SUB connectorKvaser LAPcan / LAPcan II Hardware Guide 1219 Reserved, do not connect DRVcan configurationOrange Not connected Black Shield Red Power is required Technical Data for DRVcan DNopto Technical Data for DRVcanTechnical Data for DRVcan S Technical Data for DRVcan FiTechnical Data for DRVcan LIN EMC Tests EMC ComplianceDocument revision history