Black Box IC171C manual RS-530/422/485 Line Termination, Name Function

Page 18

CHAPTER 4: Option Selection

Signal

 

Name

Pin #

Mode

GND

 

Ground

7

 

TDB

TX+

Transmit Positive

24

Output RS-422

TDA

TX-

Transmit Negative

25

Output RS-422

RDB

RX+

Receive Positive

12

Input RS-422

RDA

RX-

Receive Negative

13

Input RS-422

 

 

 

 

 

RS-530/422/485 Line Termination

Typically, each end of the RS-530/422/485 bus must have line-terminating resistors. A 100-ohm resistor is across each RS-530/422/485 input, in addition to a 1K ohm pull-up/pull-down combination that biases the receiver inputs. DIP switch SW2 allows you to customize this interface to your specific requirements. Each switch corresponds to a specific portion of the interface. If multiple RS422/485 Serial Interface Plus adapters are configured in a network, only the boards on each end should have switches 1, 2, and 3 ON. Refer to the following table for each switch’s operation:

Name

Function

T

Adds or removes the 100-ohm termination. Switch 1 ON adds the

 

termination, and OFF removes the termination.

 

 

P

Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-485

 

receiver circuit (Receive data only). Switch 2 ON adds the 1K pull-up

 

resistor and OFF removes the pull-up resistor.

P

Adds or removes the 1K ohm pull-down resistor in the RS-422/RS-485

 

receiver circuit (Receive data only). Switch 3 ON adds the 1K pull-down

 

resistor, and OFF removes the pull-down resistor.

 

 

L

Connects the TX+ to RX+ for RS-485 two-wire operation.

 

 

L

Connects the TX- to RX- for RS-485 two-wire operation.

 

 

13

Image 18
Contents RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus Contents Specifications Connectors DB25PIntroduction OverviewWhat’s Included Features Technical DescriptionRS-422/530 Connection RS-485 Two-Wire Connection Address Selection SW1C D Header E1 Factory Default. IRQ 4 Selected Option SelectionOption Selection Auto RTS EIA-530 EIA-530 SIO-485 RS-530/422/485 Line Termination Name Function11. DIP Switch SW2 Installation Software InstallationHardware Installation RS422/485 Serial Interface Plus Windows 3.1 Configuration Control PanelCancel Advanced Dont Restart Now Troubleshooting Windows 3.1, the mouse hangs or moves erratically RS422/485 Serial Interface Plus Calling Black Box Shipping and PackagingAppendix Circuit-Board Design Copyright 2000. Black Box Corporation. All rights reserved