The RS422/485 Serial Interface Plus is setup to use the AT interrupts, but there’s no interrupt response.

How to identify the problem: Verify that the interrupt jumpers are correctly set. Verify that the card is inserted into a 16-bit or AT slot.

Solution: Use the program SLT (found on your utility diskette) to verify that the interrupts are set correctly. (Note that SLT requires that the transmit and receive signals on the connector be “looped back” or connected together.

This can be accomplished by setting SW2 4 and 5 ON.)

Reason: AT IRQs are not found on the 8-bit slots only on 16-bit slots. The higher level interrupts can never be used in a PC/XT compatible system or if the board is installed in an 8-bit slot.

22

Image 27
Contents RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus Contents Connectors DB25P SpecificationsIntroduction OverviewWhat’s Included Technical Description FeaturesRS-422/530 Connection RS-485 Two-Wire Connection SW1 Address SelectionC D Option Selection Header E1 Factory Default. IRQ 4 SelectedOption Selection Auto RTS EIA-530 EIA-530 SIO-485 Name Function RS-530/422/485 Line Termination11. DIP Switch SW2 Installation Software InstallationHardware Installation RS422/485 Serial Interface Plus Control Panel Windows 3.1 ConfigurationCancel Advanced Dont Restart Now Troubleshooting Windows 3.1, the mouse hangs or moves erratically RS422/485 Serial Interface Plus Shipping and Packaging Calling Black BoxAppendix Circuit-Board Design Copyright 2000. Black Box Corporation. All rights reserved