RS422/485 SERIAL INTERFACE PLUS

7. Troubleshooting

Computer does not recognize any COM ports, or the system is “dead” or non-responsive.

How to identify the problem: Use the SSD.COM Program (found on your utility diskette).

Solution: Identify all COM ports installed on you computer and address the RS422/485 Serial Interface Plus at a different address from those already present.

Reason: Only one device can occupy an address location. If more than one device tries to share an address space, a conflict will occur, preventing either device from working.

The RS422/485 Serial Interface Plus’s address is not recognized by the system.

How to identify the problem: Use the SSD.COM Program (found on your utility diskette).

Solution: Verify that the RS422/485 Serial Interface Plus addresses are correctly set.

Reason: If the board is incorrectly addressed, your application will not respond.

The RS422/485 Serial Interface Plus transmits but does not receive. The other side appears to receive, but you do not receive any characters in your application.

How to identify the problem: Verify that the IRQ is set properly on your RS422/485 Serial Interface Plus and is correctly set in your application program.

Solution: Change the IRQs so that they are correct.

Reason: Most DOS application programs are “interrupt-driven” on receive. If the IRQ is not set on the card to match those required by your application, it will not receive characters, because the interrupt for the first character cannot be serviced.

20

Image 25
Contents RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus RS422/485 Serial Interface Plus Contents Connectors DB25P SpecificationsOverview IntroductionWhat’s Included Technical Description FeaturesRS-422/530 Connection RS-485 Two-Wire Connection SW1 Address SelectionC D Option Selection Header E1 Factory Default. IRQ 4 SelectedOption Selection Auto RTS EIA-530 EIA-530 SIO-485 Name Function RS-530/422/485 Line Termination11. DIP Switch SW2 Software Installation InstallationHardware Installation RS422/485 Serial Interface Plus Control Panel Windows 3.1 ConfigurationCancel Advanced Dont Restart Now Troubleshooting Windows 3.1, the mouse hangs or moves erratically RS422/485 Serial Interface Plus Shipping and Packaging Calling Black BoxAppendix Circuit-Board Design Copyright 2000. Black Box Corporation. All rights reserved