Black Box ME445C-X.21, ME444AE-R3, ME445C-35, ME444A-R3, ME445C-530 manual Local analog loopback

Page 43

256-KBPS LINE DRIVER (V.35, RS-530, OR X.21)

2.Verify that the DTE is operating properly and can be used for a test.

3.Perform the test using one of these methods:

Send data from the DTE and check the echoed data stream.

Hook up an external Bit Error Rate Test (BERT) unit in place of the DTE.

Use the line driver’s internal BERT. Press the PATT button.The ERR LED should light briefly just to confirm that the LED is working, and then the test will proceed. If errors are detected, the ERR LED will be continuously lit (if the errors are continuous) or will blink (for intermittent errors).

4.Repeat Steps 1 through 3 at the remote site.

5.If the BERT tests show no errors, but the data echoed back to either DTE is bad, check the DTE and the cable connecting it to the line driver—one of them is faulty.

6.After the test is complete or the fault has been corrected, restore the ANA button to its normal position. Proceed with the digital loopback tests.

DTE

 

ANA

 

DEPRESSED

DATA

 

CLK

XMTR

CLK

LINE

 

DATA

RCVR

Figure 6-4. Local analog loopback.

42

Image 43
Contents Kbps Line Driver FCC and IC RFI Statements Safety Warnings Declaration of Conformity Kbps Line Driver V.35, RS-530, or NOM Statement Trademarks Used in this Manual Contents Flow Control None SpecificationsSpecifications Physical Description IntroductionFunctional Description Line driver block diagramModulation Timing Point-to-point application ApplicationsTail-circuit application Placement of the Standalone Version ConfigurationInstalling the Card Version in the RackNest 2/14 Description of the Racknest 2/14’S Power Supply User-configurable options Configuring the Standalone or Card VersionUser-configurable options Layout of the 256-kbps Line Driver circuit board Kbps Line Driver V.35, RS-530, or Installing the Standalone Version in 19-Inch Racks InstallationInstalling a single unit in a 19-inch rack Installing two units in a 19-inch rack Installing a card in the RackNest 2/14 Installing the 256-kbps Line Driver Rackmount Card VersionRackNest 2/14 illustrated Function Installation Kbps Line Driver V.35, RS-530, or Signal ITU-TSS Lead Name Abbrev Circuit Type Rack Norm Nest PIN Pinout of the V.35 standalone’s M/34 connector DB25 DA15 Connecting Data Cables Line Connection Installation Operation Controls and IndicatorsOperation Indicators Operating ProcedureBit-Error-Rate Tester Bert TroubleshootingLoop Tests Bert using loops Local Analog Loopback Modem Self-TestLocal analog loopback Remote Digital Loopback Remote digital loopback Local Digital LoopbackLocal digital loopback Calling Black BoxShipping and Packaging 19-AWG 22-AWG 24-AWG 26-AWG Kbps Miles Appendix Maximum DistancesCopyright 2004. Black Box Corporation. All rights reserved