PRODUCT: | PSDS No. 0632 |
Section V - Emission/Exposure Information*
Light Source
Interlocked Not Visible To Operator
Electromagnetic Emissions
FCC: Class A
DOC: Class A
Audible Noise | TLV | |
Run: | 69.5 dB (A) | 85 dB (A) |
Standby: | 65.5 dB (A) |
|
Ozone |
|
|
1412 ug/min | TLV | |
0.029 ppm (TWA) | 0.1 ppm | |
0.064 ppm (Peak) |
| |
Concentration Based on Customer Simulation Model: | ||
Daily Copy Volume | 8169 copies/7.99 hours | |
Room Size | 31.16 m3 | |
1/2 Air Room Change per Hour | ||
Total Dust |
| TLV |
0.22 mg/m3 |
| 10 mg/m3 |
Selenium |
| TLV |
0.19 ug/m3 |
| 200 ug/m3 |
Arsenic |
| PEL |
0.04 ug/m3 |
| 10 ug/m3 |
*TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight hour workday.
.