Using the Remote IP Device

Restoring Factory Defaults

The “Restore Factory Settings” section on page 29 explains how to restore factory settings from the web interface. When you cannot access the system (you have forgotten the user name, IP address, or password), you can restore factory defaults from the IP Device.

To restore factory defaults:

1.Press and hold down the “Go-Local” button on the back of the IP Device for five seconds while powering up the IP Device. The IP Device will boot up in safe mode.

2.Wait 30 seconds for the IP Device to reboot.

3.Log in with the default IP address of the unit: http://192.168.2.155/config

The blank login screen will appear (no background picture).

Note: Do not start the IP address with https.

4.Type in the following default user name and password (case-sensitive), and click “Login”. This user name and password only work immediately after the reset procedure described above.

Safe-Mode User

Safe-Mode Password

 

 

admin

SAFEmode

 

 

5.From the menu, select “Restore Factory Settings”. A warning will appear advising you that all device data will be erased.

6.Click “Restore”. The factory defaults will be restored. When the process finishes, you will be prompted to reboot.

7.Click “Reboot” to restart the IP Device.

1

2

3

4

5

6

7

8

9

section

44

Image 47
Contents OmniView SMB Remote IP Device Table of Contents Using the Remote IP Device Introduction Package ContentsOverview FeaturesDigital Collaboration Video ResolutionFirmware Updates Cables Equipment RequirementsHost Computer Operating-System OS Platforms KVM SwitchesSystem Requirements Remote-Console Software KeyboardsMice MonitorsBack View Unit Display DiagramsFront View Specifications Where to place the IP Device Hardware InstallationPre-Configuration MAC Address Device Number Mounting the IP Device optionalConnecting the Console to the IP Device Hardware InstallationConnecting the KVM Switch or Server to the IP Device Connecting to a KVM Switch Connecting to a Server Powering Up the Systems Identifying the IP Address Remote InstallationInitial Settings To log into the web interface Logging into the Web InterfaceRemote Installation Three TCP Ports Network ConfigurationDevice Name Set a Static IP Enable DhcpUser User SettingsAdministrator To add a new user View OnlyTo block a user To edit a userTo delete a user Blocking a standard user and View Only userSwitch-Configuration Switch ConfigurationTo specify and name servers Installing new Switch-Definition Files SDFsTo install the SDF To configure your serial device Serial SettingsAccount Blocking Security SettingsPassword Policy SSL Certificate Idle TimeoutTo install an SSL certificate Firmware Upgrade To upgrade firmware MaintenanceLogging Out Restore Factory SettingsTo restore factory settings To start a remote session Using the Remote IP DeviceStarting a Remote Session To work in full-screen mode Full-Screen ModeDisconnecting the Remote Session Using the Quick-Access ToolbarMoving or Hiding the Quick-Access Toolbar Mouse-Pointer Calibration Mouse Configuration and SettingsMouse-Pointer Alignment To align mouse pointersTo manually synchronize mouse pointers Manual SettingsYou must manually synchronize the mouse pointers if Mouse-Pointer Options Windows XP Advanced-Mouse Emulation To change the mouse-emulation settingsTo add a keyboard sequence Keyboard Configuration and SettingsTo transmit a keyboard sequence Add-Special-Key Box To record a keyboard sequenceTo adjust the video manually Video Configuration and SettingsManual Video Adjust To refresh the video settingsTo adjust the video automatically Auto Video Adjust To change the bandwidth settings Performance Settings BandwidthTo connect to a different server Selecting a ServerAdditional Features To restore factory defaults Restoring Factory DefaultsWhat operating systems does the IP Device support? Frequently Asked QuestionsSection Solution TroubleshootingProblem Video quality is bad and/or grainy Glossary Glossary FCC Statement Belkin International, Inc., Limited 2-Year Product WarrantyInformation How to get service Belkin B.V