IBM 8840 manual Features and specifications

Page 15

Features and specifications

The following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply.

Racks are marked in vertical increments of 1.75 inches. Each increment is referred to as a unit, or “U.” A 1-U-high device is 1.75 inches tall.

Table 1. Features and specifications

Microprocessor:

vIntel® Xeon 2.8 GHz or higher depending on server model

v800 MHz front-side bus (FSB)

vSupport for up to two microprocessors with Intel Hyper-Threading Technology

Note: Use the Configuration/Setup Utility program to determine the type and speed of the microprocessors.

Memory:

vMinimum: 512 MB

vMaximum: 16 GB

vType: 2-way interleaved PC2-3200, ECC DDR II SDRAM, registered DIMMs only

vSizes: 256 MB, 512 MB, 1 GB, or 2 GB

Drives:

vDiskette: 1.44 MB

vDVD-ROM: IDE

Expansion bays:

vSix hot-swap, 3.5-inch drive bays (hot-swap hard disk drives installed, some models)

vOne 5.25-inch bay (DVD-ROM drive installed)

vOne 3.5-inch removable-media drive bay (diskette drive installed)

Expansion slots:

vTwo PCI-X non-hot-plug 100 MHz/64-bit (low profile)

vTwo PCI-X non-hot-plug 133 MHz/64-bit

Hot-swap fans:

vStandard: Six

vMaximum: 12 - provide redundant cooling

Hot-swap power supplies:

625 watts (100-240 V ac)

vMinimum: One

vMaximum: Two - provide redundant power

Size (2 U):

vHeight: 85.4 mm (3.36 in.)

vDepth: 702 mm (27.64 in.)

vWidth: 443.6 mm (17.5 in.)

vWeight: approximately 21.09 kg (46.5 lb) to 29.03 kg (64 lb) depending upon configuration

Integrated functions:

vBaseboard management controller

vTwo Broadcom 10/100/1000 Ethernet controllers (dual-port design) with Wake on LAN® support

vOne serial port

vOne external and one internal Ultra320 SCSI port (dual-channel controller with integrated RAID)

vThree Universal Serial Bus (USB) v1.1 or v2.0 ports

Note: The baseboard management controller is also known as the service processor.

Video controller:

vATI Radeon 7000M IGP video on system board

vCompatible with SVGA and VGA

v16 MB DDR-SDRAM video memory

Environment:

vAir temperature:

Server on: 10° to 35°C (50.0° to

95.0°F); altitude: 0 to 914.4 m (3000 ft) Decrease system temperature by 0.75°C for every 1000 feet increase in altitude.

Server off: 10° to 43°C (50.0° to

109.4°F); maximum altitude: 2133 m (7000 ft)

Shipment: -40° to 60°C (-40° to

140°F); maximum altitude: 2133 m (7000 ft)

vHumidity:

Server on/off: 8% to 80%

Shipment: 5% to 100%

Acoustical noise emissions:

vDeclared sound power, idle: 6.6 bel

vDeclared sound power, operating: 6.6 bel

Heat output:

Approximate heat output in British thermal units (Btu) per hour:

vMinimum configuration: 1230 Btu (360 watts)

vMaximum configuration: 2840 Btu (830 watts)

Electrical input:

vSine-wave input (50-60 Hz) required

vInput voltage range automatically selected

vInput voltage low range:

Minimum: 100 V ac

Maximum: 127 V ac

vInput voltage high range:

Minimum: 200 V ac

Maximum: 240 V ac

vInput kilovolt-amperes (kVA) approximately:

Minimum: 0.36 kVA

Maximum: 0.83 kVA

Notes:

1.Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.

2.These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.

Chapter 1. Introducing the IBM xSeries 346 Type 8840 3

Image 15
Contents ERserver Page ERserver Page Contents Appendix A. Getting help and technical assistance Safety Vi IBM xSeries 346 Type 8840 User’s Guide Safety Statement Safety IBM xSeries 346 Type 8840 User’s Guide Related documentation Introducing the IBM xSeries 346 TypeIBM xSeries 346 Type 8840 User’s Guide Features and specifications Features and specificationsWhat your server offers Reliability, availability, and serviceability IBM Director UpdateXpress program Front view IBM xSeries 346 Type 8840 User’s Guide ASM Rear viewServer power features Turning on the serverTurning off the server Introducing the IBM xSeries 346 Type 8840 IBM xSeries 346 Type 8840 User’s Guide Using the Configuration/Setup Utility program Configuring the serverConfiguration/Setup Utility menu choices Starting the Configuration/Setup Utility programMemory Settings Power-on PasswordAdministrator Password Advanced SetupSystem Event/Error Log Baseboard Management Controller SettingsEvent/Error Logs Post Error LogPower-on password PasswordsUsing the ServerGuide Setup and Installation CD ServerGuide featuresAdministrator password Typical operating-system installation Setup and configuration overviewInstalling your operating system without ServerGuide Enabling the Scsi HostRAID featureConfiguring the controller Select Create new RAID-1 Select Stripe SizeViewing the configuration Using the Boot Menu programConfiguring the Ethernet controllers Serial over LAN Using the baseboard management controllerBios update and configuration Command-line interface Ipmi ShellRed Hat Enterprise Linux ES 2.1 configuration Linux configurationAdd the following lines between the two image= sections Original /etc/lilo.conf contents Add the following five lines between the two title= sections Original /boot/grub/grub.conf contents Suse Sles 8.0 configuration Append the following text to the first title line Microsoft Windows 2003 Standard Edition configuration Original bootcfg program output Installing the OSA SMBridge management utility programConfiguring the server Using the baseboard management controller utility programs Using the OSA SMBridge management utility programCLI command-line interface mode Starting the SCSISelect Utility program Using the SCSISelect Utility programSCSISelect Utility menu choices Using the documentation Appendix A. Getting help and technical assistanceBefore you call Getting help and information from the World Wide Web Software service and support Hardware service and supportEdition notice Appendix B. NoticesImportant notes TrademarksProduct recycling and disposal Battery return program Industry Canada Class a emission compliance statement European Union EMC Directive conformance statementAvis de conformité à la réglementation d’Industrie Canada IBM xSeries 346 Type 8840 User’s Guide Scsi IndexSerial connector Page Part Number 31R1192