FUNCTION
CODE
OUTLINE
NOTE
FUNCTION
CODE
OUTLINE
NOTE
Immediate drive command for peripheral unit 2
<SUB> (1A)H
Drives peripheral unit 2. Pulse width is fixed at 200ms with a fixed delay time of 200 ms.
When the printer receives a <SUB> code, the command is executed immediately. Same as <EM>
Peripheral units 1 and 2 cannot be driven simultaneously.
Immediate drive command for peripheral unit 2
<EM> (19)H
Dives peripheral unit 2. Pulse width is fixed at 200 ms with a fixed delay time of 200 ms.
When the printer receives a <EM> code, the command is executed immediately. Same as <SUB>.
Peripheral units 1 and 2 cannot be driven simultaneously.
7-7. Other Control Codes
FUNCTION
CODE
OUTLINE
FUNCTION
CODE
OUTLINE
Sound buzzer
<RS> (1E)H
A short alarm is generated by the printer.
Cancel print data in buffer & Initialize printer
<CAN> (18)H
Clears the data buffer and line buffer and initializes (<ESC> “@”) all commands already set. However, the following parameters are not initialized: external device drive pulse width setting, operation switch valid/invalid selection, online switch valid/invalid selection.
For a serial interface printer, the select/deselect state for addressable mode and DC1/DC3 mode is not affected.
In