Connecting to an External Battery

WARNING: Acid spills

Use a sealed, non-spillable battery for indoor use. Common auto and marine batteries are not suitable for indoor use unless their fumes are vented outdoors. Common auto and marine batteries contain acid, which is hazardous if spilled. Wear eye protection and protective clothing when connecting the XPower Powerpack to an external battery.

To connect the XPower Powerpack to an external battery using the jump-start cables:

1.Connect the cables to the Jump-Start Cable Port on the left side of the XPower Powerpack.

2.Connect the red positive (+) clip of the cables to the red positive (+) terminal of the external battery.

3.Connect the black negative (–) clip of the cables to the black negative (–) terminal of the external battery.

WARNING: Sparking and explosion

Do not remove the cables from the Jump-Start Cable Port when the positive and negative clamps are connected to the terminals of the external battery.

To disconnect the cables from an external battery and from the XPower Powerpack:

1.To disconnect the XPower Powerpack from the external battery when the external battery is discharged or no longer needed, remove the red positive (+) clip, and then remove the black negative (–) clip.

2.Remove the cables from the Jump-Start Cable Port.

3.Recharge the XPower Powerpack as soon as possible after use.

CAUTION

Do not recharge the XPower Powerpack when an external battery is connected. The AC charger may be damaged.

975-0162-01-01

3-17

Image 43
Contents XPower Powerpack 400 Plus and 400R Owners Guide Date and Revision Conventions Used PurposeRelated Information References to XPower PowerpackImportant Safety Instructions Important Safety Instructions Important Safety Instructions Precautions When Working With Batteries 975-0162-01-01 Vii Precautions for Using Rechargeable Appliances Contents Operation MaintenanceSpecifications TroubleshootingWarranty and Product Information Xii Automatic overload About the XPower PowerpackIntroduction Comprehensive ProtectionJump-Start Cables Safety Feature Low Battery ProtectionOverheating Materials List FeaturesFeature Description XPower Powerpack FeaturesFront Panel Detail Not Required How to Condition Required ActionCharging Status Rear Panel Detail XPower Powerpack 400R only Radio Operation Air Compressor Valve connector with connector hoseLeft Side View Light ON/OFF Switch 400 Plus Light ON/OFF/Pulse Switch 400RStorage Compartment XPower Powerpack 400R shownDetachable heavy-duty jump-start cables AccessoriesOperating Conditions and Guidelines OperationChoosing a Location Dry Cool Ventilated Safe Protected from battery gasesRecharging with the AC Charger Using XPower Powerpack for the First TimeTo recharge with the AC Charger Operating AC Appliances Using the lightUnderstanding AC Appliances AC Appliance Watts a Hours b Run Time on Typical AC AppliancesTrouble Appliances Operating an AC ApplianceTo operate an AC appliance Operating 12 V DC Appliances DC Appliance Watts a Hours b To operate a 12 V DC applianceTo jump-start a vehicle or boat engine Jump-Starting a Vehicle’s EngineJump-Starting a Vehicle’s Engine Over-Temperature Safety Protection Using the Air CompressorOther Inflatables Inflating TiresTires Bicycle TiresTo inflate your vehicle, motorcycle, or bicycle tires Inflating Small Sports EquipmentTo inflate small sports equipment Using the Radio XPower Powerpack 400RPower Draw Connecting to an External BatteryListening to the AM Band Connecting to an External Battery Page Battery Maintenance MaintenanceRecharging with the AC Charger Recharging the XPower Powerpack BatteryFunction button Recharging with the DC Charging Cable Maintenance Recharging with a Generator’s Regulated 12 V DC Outlet To recharge with a solar panel Replacing the Internal BatteryBattery Life Recharging From a Solar PanelReplacing the Battery Obtaining a Replacement BatteryReplacement Battery Where to Buy To replace the battery Replacing the Incandescent Light Replacing the External Fuse Television Interference TroubleshootingCommon Problems Buzz in Audio EquipmentProblem Possible Cause Solution Troubleshooting Reference1Troubleshooting reference Charging Green Voltage at the AC Use AC wall outlet that supplies 1Troubleshooting reference Electrical Specifications SpecificationsDC Section Internal Battery Charging Controller System AC Power SectionXPower Powerpack Physical specifications Plus 400R Physical SpecificationsRadio XPower Powerpack 400R only AccessoriesPage Warranty and Product Information Warranty Page Product DisclaimerExclusions Return Material Authorization Policy Return Procedure Out of Warranty Service Serial Number Purchased From Purchase Date Information About Your System975-0162-01-01