Table 5-1 Troubleshooting reference
Problem | Possible Cause | Solution |
|
|
|
Measured AC | Use of an | The modified sine wave (MSW) |
output voltage | output of the XPower Powerpack | |
is too low. | voltmeter to read | requires a true RMS reading meter, |
| output voltage. | such as the Fluke 87 series, for |
|
| accurate measurement. |
| Battery is almost fully | Press Display Function button to |
| discharged. | verify battery status and recharge the |
|
| XPower Powerpack as necessary. |
|
| “Battery Charge %” reading on the |
|
| digital display is only accurate when |
|
| the XPower Powerpack has been |
|
| disconnected from all appliances and |
|
| all charging sources for fifteen |
|
| minutes. |
|
|
|
Charging | No AC power at the | Ensure power is available at the AC |
Status light is | AC wall outlet. | wall outlet. |
OFF when AC |
|
|
Charger is | AC Charger is faulty. | Replace the AC Charger. |
connected |
|
|
|
|
|
Green | Battery Charge (%) | Unplug the charging sources and any |
Charging | reading on digital | appliances and let the XPower |
Status light is | display is only | Powerpack rest for 15 minutes to |
flashing | accurate when the | obtain an accurate reading. |
(indicating | XPower Powerpack |
|
recharging) | has been disconnected |
|
and Battery | from all appliances |
|
Charge (%) | and all charging |
|
does not turn | sources for fifteen |
|
on. | minutes. |
|
|
|
|