Specifications

AC Power Section

 

Output power

 

 

 

 

• Continuous output power

 

320 W

 

 

• Five minute AC output power

 

400 W

 

 

• AC output surge capacity

 

600 W

 

 

 

 

 

 

 

Output voltage

 

115 ± 10 V AC RMS

 

 

 

 

 

 

 

Output frequency

 

60 Hz ± 4 Hz

 

 

 

 

 

 

 

Output wave form

 

modified sinewave

 

 

 

 

 

 

 

No load current draw

 

<0.20 A DC

 

 

 

 

 

 

 

Input voltage range

 

10.5 to 15.0 V DC

 

 

 

 

 

 

 

Low battery alarm

 

11.0 V DC

 

 

 

 

 

 

 

Low battery shutdown

 

10.5 V DC

 

 

 

 

 

 

 

High battery voltage shutdown

 

Yes, automatic reset

 

 

 

 

 

 

 

Over temperature shutdown

 

Yes, automatic reset

 

 

 

 

 

 

 

Overload shutdown

 

Yes, automatic reset

 

 

 

 

 

 

 

AC output short circuit protection

 

Yes, automatic reset

 

 

 

 

 

 

 

Fuse (internal)

 

2 x 25 A or 1 x 50 A

 

 

 

 

 

 

 

Operating temperature range

 

32 – 104 ºF

 

 

 

 

(0 – 40 ºC)

 

 

 

 

 

 

 

Storage temperature range

 

32 – 86ºF

 

 

 

 

(0 – 30 ºC)

 

 

 

 

 

 

 

 

 

 

 

 

Internal Battery Charging Controller System

 

 

 

 

 

 

 

AC Charger bulk charging current

 

750 mA

 

 

 

 

 

 

 

Peak charging voltage (nominal)

 

14.2 V

 

 

 

 

 

 

 

Charge restart voltage (nominal)

 

12.9 V

 

 

 

 

 

 

 

Float charge after full charge is completed

 

1 mA

 

 

(nominal)

 

 

 

 

 

 

 

 

 

AC Charger input socket maximum current

 

2.5 A

 

 

 

 

 

 

 

 

 

 

 

A-2

975-0162-01-01

Image 62
Contents XPower Powerpack 400 Plus and 400R Owners Guide Date and Revision Purpose Conventions UsedReferences to XPower Powerpack Related InformationImportant Safety Instructions Important Safety Instructions Important Safety Instructions Precautions When Working With Batteries 975-0162-01-01 Vii Precautions for Using Rechargeable Appliances Contents Maintenance OperationWarranty and Product Information TroubleshootingSpecifications Xii Comprehensive Protection About the XPower PowerpackIntroduction Automatic overloadOverheating Low Battery ProtectionJump-Start Cables Safety Feature Features Materials ListFront Panel Detail XPower Powerpack FeaturesFeature Description Required How to Condition Required Action NotCharging Status Rear Panel Detail XPower Powerpack 400R only Radio Operation Valve connector with connector hose Air CompressorLight ON/OFF Switch 400 Plus Light ON/OFF/Pulse Switch 400R Left Side ViewXPower Powerpack 400R shown Storage CompartmentAccessories Detachable heavy-duty jump-start cablesOperation Operating Conditions and GuidelinesDry Cool Ventilated Safe Protected from battery gases Choosing a LocationTo recharge with the AC Charger Using XPower Powerpack for the First TimeRecharging with the AC Charger Understanding AC Appliances Using the lightOperating AC Appliances Run Time on Typical AC Appliances AC Appliance Watts a Hours bOperating an AC Appliance Trouble AppliancesTo operate an AC appliance Operating 12 V DC Appliances To operate a 12 V DC appliance DC Appliance Watts a Hours bJump-Starting a Vehicle’s Engine To jump-start a vehicle or boat engineJump-Starting a Vehicle’s Engine Using the Air Compressor Over-Temperature Safety ProtectionBicycle Tires Inflating TiresTires Other InflatablesInflating Small Sports Equipment To inflate your vehicle, motorcycle, or bicycle tiresUsing the Radio XPower Powerpack 400R To inflate small sports equipmentListening to the AM Band Connecting to an External BatteryPower Draw Connecting to an External Battery Page Maintenance Battery MaintenanceFunction button Recharging the XPower Powerpack BatteryRecharging with the AC Charger Recharging with the DC Charging Cable Maintenance Recharging with a Generator’s Regulated 12 V DC Outlet Recharging From a Solar Panel Replacing the Internal BatteryBattery Life To recharge with a solar panelReplacement Battery Where to Buy Obtaining a Replacement BatteryReplacing the Battery To replace the battery Replacing the Incandescent Light Replacing the External Fuse Buzz in Audio Equipment TroubleshootingCommon Problems Television InterferenceTroubleshooting Reference Problem Possible Cause Solution1Troubleshooting reference Charging Green Voltage at the AC Use AC wall outlet that supplies 1Troubleshooting reference DC Section SpecificationsElectrical Specifications AC Power Section Internal Battery Charging Controller SystemAccessories Physical SpecificationsRadio XPower Powerpack 400R only XPower Powerpack Physical specifications Plus 400RPage Warranty and Product Information Warranty Page Exclusions DisclaimerProduct Return Material Authorization Policy Return Procedure Out of Warranty Service Information About Your System Serial Number Purchased From Purchase Date975-0162-01-01