Transition Networks SSDTF1029-106, SSDTF1029-107, SSDTF1029-108 specifications SSDTF10xx-10x

Page 1

User’s Guide

SSDTF10xx-10x

Stand-Alone Devices

T1 / E1 with Remote Management

Copper to Fiber

Transition Networks SSDTF10xx-10x series Devices encode and decode T1 or E1 twisted-pair copper signals over fiber optic cable to extend the distance and transmission reliability of high-speed

T1 or E1 data traffic. The device is framing independent (as ESF vs. D4) and supports all common line codes (e.g., AMI, B8ZS, HDB3).

The SSDTF10xx-10x is designed to be installed in pairs. For example, install one SSDTF1011-105 as the “local ” Device and another SSDTF1011-105 as the “remote ” Device.

 

Part Number

Port One - Copper

Port Two - Duplex Fiber-Optic

 

SSDTF1011-105

RJ-45

ST, 850 nm multimode

 

 

1.5 km (5,000 feet)*

2 km (1.2 miles)*

 

SSDTF1012-105

RJ-45

ST, 1310 nm single mode

 

 

1.5 km (5,000 feet)*

8 km (4.8 miles)*

 

 

 

 

 

SSDTF1013-105

RJ-45

SC, 850 nm multimode

 

 

1.5 km (5,000 feet)*

2 km (1.2 miles)*

 

 

 

 

 

SSDTF1014-105

RJ-45

SC, 1310 nm single mode

 

 

1.5 km (5,000 feet)*

20 km (12.4 miles)*

 

 

 

 

 

SSDTF1015-105

RJ-45

SC, 1310 nm single mode

 

 

1.5 km (5,000 feet)*

40 km (24.8 miles)*

 

 

 

 

 

SSDTF1016-105

RJ-45

SC, 1310 nm single mode

 

 

1.5 km (5,000 feet)*

60 km (37.3 miles)*

 

SSDTF1017-105

RJ-45

SC, 1550 nm single mode

 

 

1.5 km (5,000 feet)*

80 km (49.7 miles)*

 

 

 

 

 

SSDTF1018-105

RJ-45

MT-RJ, 1300 nm multimode

 

 

1.5 km (5,000 feet)*

2 km (1.2 miles)*

 

 

 

 

 

SSDTF1022-105

RJ-45

ST, 1310 nm single mode

 

 

1.5 km (5,000 feet)*

15 km (9.3 miles)*

 

 

 

 

 

SSDTF1025-105

RJ-45

MT-RJ, 1310 nm single mode

 

 

1.5 km (5,000 feet)*

20 km (12.4 miles)*

 

 

 

 

 

SSDTF1027-105 RJ-45

ST, 1300 nm multimode

 

 

1.5 km (5,000 feet)*

5 km (3.1 miles)*

 

* Typical maximum cable distance. (Actual

 

 

 

Installation . . . . . . . . . . . . . . . . . . . . .3

 

 

distance is dependent upon the physical

Operation . . . . . . . . . . . . . . . . . . . . . .9

 

 

characteristics of the network.)

Cable Specifications . . . . . . . . . . . . .10

 

 

Note: The SSDTF10xx-10x requires a CSU

Technical Specifications . . . . . . . . . .12

 

 

Troubleshooting . . . . . . . . . . . . . . . .13

 

 

between the device and the Public Telephone

 

 

Compliance Information . . . . . . . . .16

 

 

Network.

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 1
Contents SSDTF10xx-10x Set the MDI/MDI-X switch hardware mode only InstallationSet the hardware/software jumper Set the configuration switches Set the loop-back switchHardware mode Software modeT1/short-haul signal Settings forT1 configuration right switch set, SWT1/long-haul signal Operation Fiber cable Cable SpecificationsCopper cable Troubleshooting Technical SpecificationsTechnical support Contact UsTransition now Web-based seminars Mail Declaration of ConformityEuropean regulations Compliance InformationAchtung Trademark notice