Transition Networks SSDTF1027-105 specifications Settings forT1 configuration right switch set, SW

Page 4

SSDTF10xx-10x

Installation -- Continued

Settings forT1 configuration (right switch set, SW 1)

T1/long-haul signal

Use switches 3 and 4 on the left switch set to select T1/long-haul signal (see the drawing below).

Use switches 1 and 2 on the right switch set to select the proper network cable settings. The drawing below lists the four options.

3

4

1

2

3

4

Installation -- Continued

T1/short-haul signal

Use switches 3 and 4 on the left switch set to select T1/short-haul signal (see the drawing below).

Use switches 1, 2, and 3 on the right switch set to select the proper network cable settings. The drawing below lists the seven options.

3 4 1 2 3 4

(T1/Short Haul) DSX-1 162.5 - 200 m (533 - 655') 100 ohm cable

(T1/Long-Haul)

-22.5 db 100 ohm cable

 

 

DSX-1

121.6 - 162.5 m

 

(399 - 533') 100 ohm cable

-15.0 db 100 ohm cable

-7.5 db 100 ohm cable

(Switches 3 and 4 on the right switch set are not used for configuring T1/long- haul signals.)

0.0 db 100 ohm cable

DSX-1 81 - 121.6 m

(266 - 399') 100 ohm cable

DSX-1 40.5 - 81 m

(133 - 266') 100 ohm cable

DSX-1 0 - 40.5 m (0 - 133') ANSI T1.403

100 ohm cable

or

DSX-1 0 - 40.5 m

(0 - 133') 100 ohm cable

DSX-1 6.0 V 100 ohm cable

(Switch 4 on the right switch set is not used for configuring T1/short- haul signals.)

6

7

Image 4
Contents SSDTF10xx-10x Set the MDI/MDI-X switch hardware mode only InstallationSet the hardware/software jumper Set the loop-back switch Set the configuration switchesHardware mode Software modeT1/short-haul signal Settings forT1 configuration right switch set, SWT1/long-haul signal Operation Fiber cable Cable SpecificationsCopper cable Technical Specifications TroubleshootingContact Us Technical supportTransition now Web-based seminars Mail Declaration of ConformityCompliance Information European regulationsAchtung Trademark notice