Transition Networks SSEFE10XX-10X specifications Cable Specifications, Copper Cable Fiber Cable

Page 4

SSEFE10xx-10x

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Cable Specifications -- Continued

Copper Cable

Fiber Cable

Bit Error Rate:

Single mode:

SSEFE1012-100

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

SSEFE1014-100

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

SSEFE1015-100

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

SSEFE1022-100

Fiber Optic Transmitter Power:

Fiber Optic Receiver Sensitivity:

Link Budget:

SSEFE1029-100

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

SSEFE1029-101

Fiber-optic Transmitter Power:

Fiber-optic Receiver Sensitivity:

Link Budget:

<10-99 µm

1310 nm single mode

min: -15.0 dBm

max: -8.0 dBm

min: -32.0 dBm

max: -5.0 dBm

17.0 dB

 

1310 nm single mode

min: -15.0 dBm

max: -8.0 dBm

min: -32.0 dBm

max: -5.0 dBm

17.0 dB

 

1310 nm single mode

min: -8.0 dBm

max: -2.0 dBm

min: -34.0 dBm

max: -5.0 dBm

26.0 dB

 

1310 nm single mode

min: -8.0 dBm

max: -2.0 dBm

min: -34.0 dBm

max: -5.0 dBm

26.0 dB

 

1310 nm (TX)/1550 nm (RX) simplex

min: -14.0 dBm

max: -8.0 dBm

min: -33.0 dBm

max: -3.0 dBm

19.0 dB

 

1550 nm (TX)/1310 nm (RX) simplex

min: -14.0 dBm

max: -8.0 dBm

min: -33.0 dBm

max: -3.0 dBm

19.0 dB

 

Category 3: (Minimum requirement for 10 Mb/s operation)

Gauge

24 to 22 AWG

Attenuation

11.5 dB/100m @ 5-10 MHz

Category 5: (Minimum requirement for 100 Mb/s operation)

Gauge

24 to 22 AWG

Attenuation

22.0 dB /100m @ 100 MHz

Straight-through or crossover copper cable may be used.

Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .

RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

Do not use flat or silver satin wire.

 

Straight-Through Cable

 

Crossover Cable

 

 

Twisted Pair #1

 

 

1

 

 

1

 

Twisted Pair #1

1

 

 

1

 

 

 

2

 

 

 

2

 

2

 

 

2

 

 

 

 

 

 

 

 

 

 

Twisted Pair #2

 

 

3

 

 

3

 

Twisted Pair #2

3

 

 

3

 

 

 

 

 

 

 

 

 

6

 

 

 

6

 

6

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.

6

24-Hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat

7

Image 4
Contents Part Number Port Two Fiber OpticSSEFE1012-100 SSEFE1014-100Installation Set Link Pass-Through switchSet the Speed switch Power the Media ConverterInstall the Fiber Cable Install the Copper CableOperation Status LEDsCable Specifications Copper Cable Fiber CableTechnical Specifications TroubleshootingContact Us Compliance Information European RegulationsTrademark Notice Copyright Restrictions