Technical Specifications
For use with Transition Networks Model
Standards: | IEEE 802.3™, |
Data Rate: | 10 Mb/s, 100 Mb/s |
Dimensions | 3.25" x 4.7" x 1.0" (83 mm x 119 mm x 25 mm) |
Weight | 10 oz. ( 283 g) (approximate) |
Power Consumption: | 3.6 watts |
Power Supply | 12VDC, 0.5 Amp (North America) |
| 12VDC, 0.41 Amp (Europe, Japan, Latin Am.) |
| 12VDC, 1.25 Amp (UK, Australia, South Africa) |
Environment: | Tmra*: 0° to 50°C (32° to 122°F) |
| Storage Temperature: |
| Humidity: 5 to 95%, non condensing |
| Altitude: 0 to 10,000 feet |
Warranty: | Lifetime |
*Manufacturer’s rated ambient temperature:
NOTE: The information in this user’s guide is subject to change. For the most
The chassis version of the media converter is the
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
8
Troubleshooting
1.Is the PWR LED on the media converter illuminated?
NO
•Ensure that the power adapter is the proper type of voltage and cycle frequency for the outlet (See “Power Supply” on page 8.)
•Ensure the power adapter is properly installed in the media converter and in the grounded outlet.
•Contact Tech Support:
YES
•Go to step 2.
2.Is the F-ACT LED illuminated?
NO
•Check the fiber cables for proper connection.
•Verify that the TX and RX cables on the media converter are connected to the RX and TX ports, respectively, on the other media converter.
•Contact Tech Support:
YES
•Go to step 3.
3.Is the F-ACT LED blinking?
NO
•If there is no activity on the fiber port, go to step 4.
•If there is activity on the fiber port, disconnect and reconnect the fiber cable to restart the initialization process.
•Restart the workstation to restart the initialization process.
•Contact Tech Support:
YES
•Go to step 4.
4.Are the
YES
•The media converter is set to 100Mb/s for both the copper fiber links. If this is not the correct speed, carefully remove the media converter from the chassis and set switch 1 to “down” (speed = 10 Mb/s).
•Contact Tech Support:
NO
•Go to step 5.
5.Are the
YES
•The media converter is set to 10 Mb/s for the copper and fiber links. If this is not the correct speed, carefully remove the media converter from the chassis and set switch 2 to “up” (speed = 100 Mb/s).
•Contact Tech Support:
NO
•Go to step 6.
techsupport@transition.com