Transition Networks CSRFB10XX-100 Cable Specifications, Bandwidth allocation, Fiber cable

Page 6

CSRFB10xx-100

Operation -- Continued

Product features - continued

Bandwidth allocation

Bandwidth allocation feature is available on the Center located SRFB converter only. The center converter supports independent ingress rate limiting on both the copper and fiber ports. The increments range from 64kps up to full bandwidth. This feature is controlled by a Point System management module installed in a Point System Chassis, along with the SW6 position of the CSRFB converter set to ‘center’ The following rates are available for all traffic:

64 Kbps

128 Kbps

256 Kbps

512 Kbps

1 Mbps

2 Mbps

4 Mbps

8 Mbps

16 Mbps

32 Mbps

64 Mbps

72 Mbps

80 Mbps

88 Mbps

No Limit

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Fiber cable

Bit Error Rate:

<10-9

 

Single mode fiber (recommended):

9 µm

 

Multimode fiber (recommended):

62.5/125 µm

 

Multimode fiber (optional):

100/140, 85/140, 50/125 µm

CSRFB1011-100

multimode

 

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

 

CSRFB1013-100

multimode

 

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

 

CSRFB1014-100

single mode

 

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

 

CSRFB1029-100

1310TX/1550

 

CSRFB1029-101

1550TX/1310 single mode

Fiber-optic Transmitter Power:

min: -14.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

 

CSRFB1029-102

1310TX/1550

 

CSRFB1029-103

1550TX/1310 single mode

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

 

Copper cable maximum cable distance: 100 meters

 

Category 3: (Minimum requirement for 10 Mbps operation)

 

Gauge

24 to 22 AWG

 

Attenuation

11.5 dB/100m @ 5-10 MHz

Category 5: (Minimum requirement for 100 Mbps operation)

 

Gauge

24 to 22 AWG

 

Attenuation

22.0 dB /100m @ 100 MHz

Straight-through (MDI) or crossover (MDI-X) twisted-pair cable must be used.

Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

 

Straight-Through Cable

 

Crossover Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Twisted Pair #1

 

 

 

 

 

 

Twisted Pair #1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Twisted Pair #2

 

 

 

 

 

 

Twisted Pair #2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

24-hour Technical Support: 1-200-260-1312 -- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

11

Image 6
Contents User’s Guide CSRFB10xx-100Hardware/software mode jumper InstallationTypical system configuration 6-position switchInstall the slide-in-module AutoCross jumperLoopback test Product Features Install the twisted-pair copper cableInstall the fiber cable OperationParallel detection Far-end faultTransparent link pass-through Tlpt Full duplex networkCable Specifications Bandwidth allocationFiber cable Technical Specifications TroubleshootingContact Us Is remote converter detected?Compliance Information Canadian regulations