Operation -- Continued
Product features - continued
Bandwidth allocation
Bandwidth allocation feature is available on the Center located SRFB converter only. The center converter supports independent ingress rate limiting on both the copper and fiber ports. The increments range from 64kps up to full bandwidth. This feature is controlled by a Point System management module installed in a Point System Chassis, along with the SW6 position of the CSRFB converter set to ‘center’ The following rates are available for all traffic:
•64 Kbps
•128 Kbps
•256 Kbps
•512 Kbps
•1 Mbps
•2 Mbps
•4 Mbps
•8 Mbps
•16 Mbps
•32 Mbps
•64 Mbps
•72 Mbps
•80 Mbps
•88 Mbps
•No Limit
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber cable
Bit Error Rate: |
| |
Single mode fiber (recommended): | 9 µm |
|
Multimode fiber (recommended): | 62.5/125 µm |
|
Multimode fiber (optional): | 100/140, 85/140, 50/125 µm | |
multimode |
| |
Fiber Optic Transmitter Power: | min: | max: |
Fiber Optic Receiver Sensitivity: | min: | max: |
Link Budget: | 11.0 dB |
|
multimode |
| |
Fiber Optic Transmitter Power: | min: | max: |
Fiber Optic Receiver Sensitivity: | min: | max: |
Link Budget: | 11.0 dB |
|
single mode |
| |
min: | max: | |
min: | max: | |
Link Budget: | 16.0 dB |
|
1310TX/1550 |
| |
1550TX/1310 single mode | ||
min: | max: | |
min: | max: | |
Link Budget: | 19.0 dB |
|
1310TX/1550 |
| |
1550TX/1310 single mode | ||
min: | max: | |
min: | max: | |
Link Budget: | 25.0 dB |
|
Copper cable maximum cable distance: 100 meters |
| |
Category 3: (Minimum requirement for 10 Mbps operation) |
| |
Gauge | 24 to 22 AWG |
|
Attenuation | 11.5 dB/100m @ | |
Category 5: (Minimum requirement for 100 Mbps operation) |
| |
Gauge | 24 to 22 AWG |
|
Attenuation | 22.0 dB /100m @ 100 MHz |
•
•Shielded
•Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
•Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
|
| Crossover Cable | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Twisted Pair #1 |
|
|
|
|
|
| Twisted Pair #1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Twisted Pair #2 |
|
|
|
|
|
| Twisted Pair #2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 | techsupport@transition.com | 11 |