Operation -- Continued
Setting the password:
1.At the prompt, press the letter “P” key.
2.At the prompt, type any alphanumeric combination (8 characters maximum)
3.Press the ENTER key: the password is set.
Important: After setting up or changing command parameter(s) you must save the change(s) before exiting the screen or the change(s) will not go into effect.
To show the current configuration:
1.At the prompt, press the letter “D” key.
2.Press the ENTER key and the current configuration will appear as shown below:
----Local Device
Ethernet: AutoNeg, 100Mbs, HD, LPT
T1/E1 #1:
T1/E1 #2:
T1/E1 #3:
T1/E1 #4:
Serial : 9600, No Parity
DMI: Not Detected. VLAN: Disabled
----Remote Device
Ethernet: AutoNeg, 100Mbs, FD, LPT
T1/E1 #1:
T1/E1 #2:
T1/E1 #3:
T1/E1 #4:
Serial : 9600, No Parity
DMI: Not Detected.
Operation -- Continued
To show the configuration menu for the local device:
1.At the prompt, type the letter “C,” press the spacebar, then type the letter “L.”
2.Press the ENTER key and the local device configuration menu will appear as shown below:
Note: In this menu, the T1/E1/J1 commands for local loopback, for example, type the command this way: LL, press the spacebar, then type the port number, press spacebar, then type the
number of the command, in this case (1= enable or 2 = disable).
The command sequence IS NOT case sensitive.
Local Device Configuration Menu:
*T1/E1/J1:
LLx 1 - Local Loopback on T1/E1/J1 Port x ENABLE LL x 2 - Local Loopback on T1/E1/J1 Port x DISABLE RL x 1 - Remote Loopback on T1/E1/J1 Port x ENABLE RL x 2 - Remote Loopback on T1/E1/J1 Port x DISABLE XE x - Enable Transmit AIS on LOS for Port x
XD x - Disable Transmit AIS on LOS for Port x EB x - Encoding set to B8ZS on Port x
EA x - Encoding set to AMI on Port x
B x - Serial port baud rate
(1=9600, 2=19200, 3=36400, 4=57600) *Enet 10/100:
A1 - Autonegotiation ENABLE
A2 - Autonegotiation DISABLE
TLPT1 - Transparent Link Pass Through ENABLE TLPT2 - Transparent Link Pass Through DISABLE
F10 - Force 10Mbps
F100 - Force 100Mbps
FF - Force Full Duplex
FH | - Force Half Duplex |
S- Save new Configuration and Exit
Q - Exit without saving Configuration
14 | techsupport@transition.com | 15 |