SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T)
Technical Specification -- Continued
This device has been evaluated as EEx nC IIC T4 equipment under DEMKO Certificate No. 03 ATEX 0324537U. Each module is suitable for use in Zone 2 Explosive Atmospheres. The device must be installed in a minimum IP 54 enclosure as defined in IEC 60529 and EN 60529.
This device is a
EMS Type Tests
Test | Description |
| Test Levels | Severity |
|
|
|
|
|
ESD | Air discharge | +/- 8 KV | 3 | |
|
| Contact discharge | +/- 6 KV | 3 |
|
|
|
|
|
|
| ESD contact discharge | +/- 6 KV | 3 |
|
|
|
|
|
Radiated RFI | Housing | 10V/m, 80 MHz - 1 GHz | 3 | |
|
|
| AM 1 KHz, 80% mod |
|
|
|
| 10 V/m, 0.9 - 1.8 GHz |
|
|
|
| FM 200 Hz 50% square |
|
|
|
|
|
|
Burst | Power supply lines | +/- 2 KV | 3 | |
| (Fast Transient) |
|
|
|
| Communication lines | +/- 1 KV | 3 | |
|
| Relay | +/- 1 KV | 3 |
|
|
|
|
|
Surge | Power supply lines | +/- 2 KV, 12 Ω, CM | 3 | |
|
|
| +/- 1 KV, 2 Ω, DM |
|
|
|
|
|
|
|
| Relay | +/- 2 KV, 12 Ω, CM | 3 |
|
|
| +/- 1 KV, 2 Ω, DM |
|
|
|
|
|
|
Induced | Power supply lines | 10 Vrms, | 3 | |
| (Conducted RFI) |
| AM 1 KHz, 80% mod |
|
|
|
|
|
|
|
| Communication lines | 10 Vrms, | 3 |
|
|
| AM 1 KHz, 80% mod |
|
|
|
|
|
|
|
| Relay | 10 Vrms, | 3 |
|
|
| AM 1 KHz, 80% mod |
|
|
|
|
|
|
Environmental Type Tests
Test | Description | Test Levels |
|
|
|
IEC | Vibration | 10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes) |
IEC | Shock | 50 g, 11 ms, |
|
|
|
IEC | Free fall | 75 cm, 1 corner, 3 edges, 6 faces (total 10 drops) |
|
|
|
Troubleshooting
If the device fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1.Is the PWR1 LED illuminated?
NO
•Ensure the power source is the proper voltage (12 - 48 VDC).
•Ensure the (+) and
•Contact Tech Support:
YES
•Proceed to step 2.
2.Is the PWR2 LED illuminated?
NO
•Ensure the power source is the proper voltage (12 - 48 VDC).
•Ensure the (+) and
•Contact Tech Support:
YES
•Proceed to step 3.
3.Is the FAULT LED illuminated?
YES
•If one or more port alarm switches (1 - 5) is ON, the device lost the corresponding fiber or copper link, or the primary power or backup power.
•Ensure the problem copper or fiber link is properly connected.
•Contact Tech Support:
NO
•Proceed to step 4.
4.Is a 100M LED (near a fiber link) illuminated?
NO
•Check the corresponding fiber cables for proper connection.
•Verify that the TX and RX cables on the device are connected to the RX and TX ports, respectively, on the other device.
•Contact Tech Support:
YES
•Proceed to step 5.