Transition Networks SISTF10XX-140-LR(T) specifications Technical Specification, Troubleshooting

Page 9

SISTF10xx-140-LR(T) / -160-LR(T) / -170-LR(T)

Technical Specification -- Continued

This device has been evaluated as EEx nC IIC T4 equipment under DEMKO Certificate No. 03 ATEX 0324537U. Each module is suitable for use in Zone 2 Explosive Atmospheres. The device must be installed in a minimum IP 54 enclosure as defined in IEC 60529 and EN 60529.

This device is a building-in type. The installation into a certain end equipment shall comply with fire enclosure request of IEC 60950/EN60950 or similar sentence.

EMS Type Tests

Test

Description

 

Test Levels

Severity

 

 

 

 

 

IEC61000-4-2

ESD

Air discharge

+/- 8 KV

3

 

 

Contact discharge

+/- 6 KV

3

 

 

 

 

 

 

 

ESD contact discharge

+/- 6 KV

3

 

 

 

 

 

IEC61000-4-3

Radiated RFI

Housing

10V/m, 80 MHz - 1 GHz

3

 

 

 

AM 1 KHz, 80% mod

 

 

 

 

10 V/m, 0.9 - 1.8 GHz

 

 

 

 

FM 200 Hz 50% square

 

 

 

 

 

 

IEC61000-4-4

Burst

Power supply lines

+/- 2 KV

3

 

(Fast Transient)

 

 

 

 

Communication lines

+/- 1 KV

3

 

 

Relay

+/- 1 KV

3

 

 

 

 

 

IEC61000-4-5

Surge

Power supply lines

+/- 2 KV, 12 , CM

3

 

 

 

+/- 1 KV, 2 , DM

 

 

 

 

 

 

 

 

Relay

+/- 2 KV, 12 , CM

3

 

 

 

+/- 1 KV, 2 , DM

 

 

 

 

 

 

IEC61000-4-6

Induced

Power supply lines

10 Vrms, 150-80 MHz

3

 

(Conducted RFI)

 

AM 1 KHz, 80% mod

 

 

 

 

 

 

 

 

Communication lines

10 Vrms, 150-80 MHz

3

 

 

 

AM 1 KHz, 80% mod

 

 

 

 

 

 

 

 

Relay

10 Vrms, 150-80 MHz

3

 

 

 

AM 1 KHz, 80% mod

 

 

 

 

 

 

Environmental Type Tests

Test

Description

Test Levels

 

 

 

IEC 60068-2-6

Vibration

10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes)

IEC 60068-2-27

Shock

50 g, 11 ms, +/-X, +/-Y, +/- Z (6 direction)

 

 

 

IEC 60068-2-32

Free fall

75 cm, 1 corner, 3 edges, 6 faces (total 10 drops)

 

 

 

Troubleshooting

If the device fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:

1.Is the PWR1 LED illuminated?

NO

Ensure the power source is the proper voltage (12 - 48 VDC).

Ensure the (+) and (-) wires from the power source are inserted properly in the terminal block contacts labeled “PWR1”.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 2.

2.Is the PWR2 LED illuminated?

NO

Ensure the power source is the proper voltage (12 - 48 VDC).

Ensure the (+) and (-) wires from the power source are inserted properly in the terminal block contacts labeled “PWR2”.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 3.

3.Is the FAULT LED illuminated?

YES

If one or more port alarm switches (1 - 5) is ON, the device lost the corresponding fiber or copper link, or the primary power or backup power.

Ensure the problem copper or fiber link is properly connected.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 4.

4.Is a 100M LED (near a fiber link) illuminated?

NO

Check the corresponding fiber cables for proper connection.

Verify that the TX and RX cables on the device are connected to the RX and TX ports, respectively, on the other device.

Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 5.

16

24-hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

17

Image 9
Contents Stand-Alone Ethernet Switch SISTF10xx-140-LRT / -160-LRT / -170-LRT Ground the Ethernet Switch InstallationInstall the Fiber Cable Install the Copper CableSet the Port Alarm Switches Install the Port Alarm DeviceInternal Relay Power the Ethernet switch FeaturesOperation Status LEDs Power and Fault LEDsFiber Port LEDs Copper Port LEDsExtended Temperature Models Cable SpecificationsFiber Cable Standard ModelsCopper Cable Technical SpecificationsTmra* standard temp Tmra* extended tempTroubleshooting Technical SpecificationIs a 100M LED near the fiber links flashing? Contact UsAre any of the 10M LEDs on the RJ-45 port illuminated? Are any of the 100M LEDs on the RJ-45 port illuminated?33311.A Compliance Information