Fujitsu MB39A105 manual Usage Precaution, Ordering Information, Do not apply negative voltages

Page 25

MB39A105

USAGE PRECAUTION

Printed circuit board ground lines should be set up with consideration for common impedance.

Take appropriate static electricity measures.

Containers for semiconductor materials should have anti-static protection or be made of conductive material.

After mounting, printed circuit boards should be stored and shipped in conductive bags or containers.

Work platforms, tools, and instruments should be properly grounded.

Working personnel should be grounded with resistance of 250 kΩ to 1 MΩ between body and ground.

Do not apply negative voltages.

The use of negative voltages below –0.3 V may create parasitic transistors on LSI lines, which can cause abnormal operation.

ORDERING INFORMATION

Part number

Package

Remarks

MB39A105PFT

8-pin plastic TSSOP (FPT-8P-M05)

25

Image 25
Contents Description FeaturesPackage PIN Assignment PIN Description Pin No Symbol DescriptionsBlock Diagram Parameter Symbol Condition Value Unit Min Typ Parameter Symbol Condition Rating Unit Min MaxAbsolute Maximum Ratings Recommended Operating ConditionsParameter Electrical CharacteristicsPin Conditions Value Unit Min Typ Max Error Typical CharacteristicsTriangularwave oscillation Power Dissipation vs. Ambient Temperature Functions Error amplifier block Error Amp1, Error Amp2Triangular-wave oscillator block OSC PWM comparator block PWM CompTimer-latch short-circuit protection circuit SCP PowerUnder voltage lockout protection circuit Uvlo Short-circuit protection detection output functionSetting the Triangular Oscillation Frequency Setting the Output VoltageSetting the SOFT-START Times Timer-latch short-circuit protection circuit MB39A105 Equivalent Circuit Application Parts No Parts ListSelection of Components 2I OV O 2LV O Peak-to-peak value ESR Reference Data Ordering Information Usage PrecautionDo not apply negative voltages Part number Package RemarksIndex Package DimensionFujitsu Limited