Fujitsu P2X0-0202-01EN manual Alarm History Index URL, Number of Days Alarm History Files are Kept

Page 26

2.3 Setting Items

Caution:

The alarm history files must be saved in a directory immediately under the directory in which the ETERNUSmgr Top Menu is installed. When changing the location of the alarm history file directory, ensure that all the files (index.htm, menu.htm, fujitsu.gif, eternus.gif) in the parent directory (ETERNUSmgr Top Menu directory) are also moved to the new parent directory. If using multiple setup files, ensure that any modifi- cations are consistently applied to each setup file. Setup the parent directory of the alarm history file directory (i.e. the ETERNUSmgr Top Menu directory) as a public directory on the Web server.

When monitoring multiple machines, the alarm history files for each should be saved in a different directory (specify different absolute paths in each setup file).

Refer to "2.5 Monitoring Multiple Target Devices" (page 27) for details on how to mon- itor multiple target devices.

When this parameter is changed, it is also necessary to change the alarm file URL in the top menu file ("menu.htm").

For details on how to make changes to the top menu file, refer to "2.3.1 Target Device Settings" (page 12).

If the specified Alarm History Files Directory does not exist, it will automatically be cre- ated. It is not necessary to create the directory manually.

Alarm History Index URL

Specify a URL for HTTP browsing of the Alarm History Files Directory setup in "Alarm History File Directory" (page 17). The administrator is notified of this URL via E-mail, allowing the alarm history files to be checked with a Web browser.

This parameter may not be omitted when the E-mail notification function is used (i.e. ADMIN_MAIL parameter has been set). In this case ETERNUSmgr will not start unless this parameter is set. This param- eter may be omitted if the E-mail notification function is not used (i.e. ADMIN_MAIL parameter has not been set).

[Parameter]

HTML_ALARMFILE_URL (up to 64 characters)

[Example]

When the Alarm History Files Directory is accessible as "http://host-name/eternuslog/"

HTML_ALARMFILE_URL= http://host-name/eternuslog/

Caution:

-When monitoring multiple target devices, set a different Alarm History Index URL for each device’s Alarm History Files Directory.

Refer to "2.5 Monitoring Multiple Target Devices" (page 27) for details on how to monitor multiple target devices.

-"HTML_ALARMFILE_PATH" and "HTML_ALARMFILE_URL" must be linked in the Web server settings.

Number of Days Alarm History Files are Kept

This parameter specifies how long the Alarm History files are kept. Setting the number of days to "0" means that the files are not deleted.

[Default value]

7

18

ETERNUSmgr User Guide -Introduction- P2X0-0202-01EN

All Rights Reserved, Copyright © FUJITSU LIMITED 2007

Image 26
Contents Page Page Preface Structure of this ManualFollowing are related materials Related MaterialPreface Acknowledgments AbbreviationsThis page is intentionally left blank Contents Contents IndexAbout ETERNUSmgr ETERNUSmgr OutlineClient communication ETERNUSmgr Outline ETERNUSmgr System ConfigurationNetwork Requirements About ETERNUSmgr Managing Server communication Target Device Monitoring and Failure Notification Target Device Configuration BrowserETERNUSmgr Functions ETERNUSmgr FunctionsTarget Device Setup and Maintenance Yes Can be monitored, No Cannot be monitoredMail Server ETERNUSmgr for Windows Required Software and HardwareETERNUSmgr Server Client This page is intentionally left blank Setup Setup filesSetup files Setting Items and Parameters Required by each OS Modifying the ETERNUSmgr Setup ETERNUSmgr for Solaris OS and Linux ProcedureFor Windows Setting ItemsTarget Device Settings Target AddressTarget Type When the actual polling exceeds the scheduled polling timePolling Interval POLLINGTIME=300Target Flag Detect Offline Targets Alarm Mailing Interval Mail Notification Settings Admin Mail Address Busy Target Detection TimeMail Server Smtp Port ETERNUSmgr for Windows only AdminmailsvMail Server Address ETERNUSmgr for Windows only MAILSENDTIME=300Sender Mail Address Alarm History File SettingsAlarm History File Directory Htmlalarmfileurl up to 64 characters Alarm History Index URLNumber of Days Alarm History Files are Kept Setup Parameter Alarm Text File SettingsAlarm Text Files Directory Alarm Text Date FilesLog Files Directory Log File SettingsNumber of Days Alarm Text Date Files are Kept LOGFILEDAY=7 Changing the Windows version setting to D\ETERNUSmgr\log1\Number of Days Log Files are Kept Modifying the ETERNUSmgr Top Menu System Output Log FileETERNUSmgr for Solaris OS and Linux Procedure Copying/Modifying the Top Menu FilesEditing Top Menu file menu.htm Setting the Link to the Alarm History FilesInstallation Location Machine Name Storage systems other than ETERNUS2000Setup Example ↓ Becomes HtmlMonitoring Multiple Target Devices Setup File CautionsCreating a Setup File for Each Target Device Format STX-.INIMonitoring Multiple Target Devices File name starts with STX and ends with .INI2nd Target Device ETERNUS2000#1 Adding the Extra Target Devices to the Top Menu FileExample 1st Target Device ETERNUS3000#1 3rd Target Device ETERNUS3000#2Status of 000.000.000.000 -- font color=red*Offline*/font Starting Up ETERNUSmgr Startup and ShutdownETERNUSmgr for Solaris OS and Linux ETERNUSmgr for Solaris OS and Linux Solaris OE example Setting the ETERNUSmgr Daemon for Automatic StartupShutting Down ETERNUSmgr ETERNUSmgr for Windows ETERNUSmgr for WindowsP2X0-0202-01EN ETERNUSmgr User Guide -Introduction For Windows Registering the ETERNUSmgr Service for Automatic Startup This page is intentionally left blank Control Interfaces Top Menu Select RAID Device menuShow hardware error detect log list menu ETERNUS6000Solaris OS, Linux, and Windows Version Cautions ETERNUSmgr User Guide -Introduction- P2X0-0202-01EN Detectoffline = True Uninstall Windows only cautionsMessages Alarm History MessagesExample Alarm History File YYYYMMDDHHmmSSn.htmlStxgrYYYYMMDD.log Alarm Text FilesAlarm Text Date Files ETERNUSmgr VxxLxx Http Polling engine was started Alarm Text Fixed FileMail Messages Hardware Status was changed. See belowStatus Component#Serial NumberStatusSerial number Log Messages Regular Messages CodeBad Parameter parameter Code Log Messages Server Status Change CodeWork files create to temp directory Code Undefined Parameter parameter CodeFatal Error Messages Code Cant Create Directory path Code Log Messages Cant Allocate Memory CodeBad IP Address host name or IP address Code Not Find Parameter parameter CodeAn example of log message output is shown below Result of a target device status inquiry SuccessLog Messages Logfileday Htmlalarmfilename HtmlalarmfilepathIndex Index ETERNUSmgr User Guide -Introduction P2X0-0202-01EN