Fujitsu P2X0-0202-01EN manual Detectoffline = True

Page 51

Chapter 5 Cautions

4Delete the setup files from the ETERNUSmgr directory created by the installation process.

5Move the GRmgr V10L30 (or later) setup files from their temporary location (step 1) into the ETERNUSmgr directory.

Note that ETERNUSmgr must be installed in the same directory as was used by the previous version of GRmgr (V10L30, V10L40, V10L50, V10L60). Similarly, the new www files must be installed in the old www directory, and if the old top menu file ("menu.htm") has been edited, it should be backed up and used to replace the new version.

- When using a GRmgr V10L30 setup file, append the following Detect Offline Targets parame- ter description to the setup file if you wish to use the offline detection function (available from GRmgr V10L40 onward).

# Detect Offline status

DETECT_OFFLINE = TRUE

-This flag does not need to be added to the GRmgr V10L30 setup file if the offline detection function (available from GRmgr V10L40 onward) is not going to be used.

See "Detect Offline Targets" (page 14) for details of the Detect Offline Targets parameter.

Setup files

Always ensure that the ETERNUSmgr setup file’s TARGET_FLAG parameter is correct for the monitored device type. ETERNUSmgr will be unable to monitor the target device if this setting is wrong. Note that even if the TARGET_TYPE and the TARGET_FLAG set- tings are different, ETERNUSmgr operations are not affected.

Any character string may be set in TARGET_TYPE, however it is recommended that the correct device type ("ETERNUS8000", "ETERNUS4000", "ETERNUS2000", "ETERNUS6000", "ETERNUS3000", "GR710", "GR720", "GR730", "GR740", "GR820", or "GR840") be set. The character string in TARGET_TYPE is used when the administrator is notified by E-mail, and in the alarm history files.

Edit only the parameters in the ETERNUSmgr setup file which are explained in this docu- ment. Do not delete comments or blank lines from the default setup files provided, and do not add anything other than allowed parameters. Failure to follow these requirements may result in problems, and prevent future upgrades of ETERNUSmgr. See "Chapter 2 Setup" (page 9) for details.

Install/Uninstall

See the "ETERNUS8000, ETERNUS4000, ETERNUS2000, ETERNUS6000, ETERNUS3000 ETERNUSmgr Install Guide" for details of installing and uninstalling ETERNUSmgr.

5

P2X0-0202-01EN ETERNUSmgr User Guide -Introduction-

All Rights Reserved, Copyright © FUJITSU LIMITED 2007

43

Image 51
Contents Page Page Structure of this Manual PrefaceRelated Material PrefaceFollowing are related materials Abbreviations AcknowledgmentsThis page is intentionally left blank Contents Index ContentsETERNUSmgr Outline About ETERNUSmgrETERNUSmgr Outline ETERNUSmgr System Configuration Network RequirementsClient communication About ETERNUSmgr Managing Server communication ETERNUSmgr Functions Target Device Configuration BrowserETERNUSmgr Functions Target Device Monitoring and Failure NotificationYes Can be monitored, No Cannot be monitored Target Device Setup and MaintenanceRequired Software and Hardware ETERNUSmgr ServerMail Server ETERNUSmgr for Windows Client This page is intentionally left blank Setup files SetupSetup files Setting Items and Parameters Required by each OS ETERNUSmgr for Solaris OS and Linux Procedure Modifying the ETERNUSmgr SetupTarget Address Setting ItemsTarget Device Settings For WindowsPOLLINGTIME=300 When the actual polling exceeds the scheduled polling timePolling Interval Target TypeDetect Offline Targets Target FlagBusy Target Detection Time Mail Notification SettingsAdmin Mail Address Alarm Mailing IntervalMAILSENDTIME=300 AdminmailsvMail Server Address ETERNUSmgr for Windows only Mail Server Smtp Port ETERNUSmgr for Windows onlyAlarm History File Settings Alarm History File DirectorySender Mail Address Alarm History Index URL Number of Days Alarm History Files are KeptHtmlalarmfileurl up to 64 characters Alarm Text Date Files Alarm Text File SettingsAlarm Text Files Directory Setup ParameterLog File Settings Number of Days Alarm Text Date Files are KeptLog Files Directory Changing the Windows version setting to D\ETERNUSmgr\log1\ Number of Days Log Files are KeptLOGFILEDAY=7 Output Log File Modifying the ETERNUSmgr Top Menu SystemCopying/Modifying the Top Menu Files ETERNUSmgr for Solaris OS and Linux ProcedureStorage systems other than ETERNUS2000 Setting the Link to the Alarm History FilesInstallation Location Machine Name Editing Top Menu file menu.htmSetup Example Html ↓ BecomesFormat STX-.INI Setup File CautionsCreating a Setup File for Each Target Device Monitoring Multiple Target DevicesFile name starts with STX and ends with .INI Monitoring Multiple Target Devices3rd Target Device ETERNUS3000#2 Adding the Extra Target Devices to the Top Menu FileExample 1st Target Device ETERNUS3000#1 2nd Target Device ETERNUS2000#1Status of 000.000.000.000 -- font color=red*Offline*/font Startup and Shutdown ETERNUSmgr for Solaris OS and LinuxStarting Up ETERNUSmgr ETERNUSmgr for Solaris OS and Linux Setting the ETERNUSmgr Daemon for Automatic Startup Shutting Down ETERNUSmgrSolaris OE example ETERNUSmgr for Windows ETERNUSmgr for WindowsP2X0-0202-01EN ETERNUSmgr User Guide -Introduction For Windows Registering the ETERNUSmgr Service for Automatic Startup This page is intentionally left blank Select RAID Device menu Control Interfaces Top MenuETERNUS6000 Show hardware error detect log list menuSolaris OS, Linux, and Windows Version Cautions ETERNUSmgr User Guide -Introduction- P2X0-0202-01EN Detectoffline = True Windows only cautions UninstallYYYYMMDDHHmmSSn.html Alarm History MessagesExample Alarm History File MessagesAlarm Text Files Alarm Text Date FilesStxgrYYYYMMDD.log Hardware Status was changed. See below Alarm Text Fixed FileMail Messages ETERNUSmgr VxxLxx Http Polling engine was startedComponent#Serial NumberStatus Serial numberStatus Regular Messages Code Log MessagesUndefined Parameter parameter Code Log Messages Server Status Change CodeWork files create to temp directory Code Bad Parameter parameter CodeFatal Error Messages Code Not Find Parameter parameter Code Log Messages Cant Allocate Memory CodeBad IP Address host name or IP address Code Cant Create Directory path CodeResult of a target device status inquiry Success An example of log message output is shown belowLog Messages Htmlalarmfilename Htmlalarmfilepath IndexLogfileday Index ETERNUSmgr User Guide -Introduction P2X0-0202-01EN