Fujitsu PRN607-S manual 2-13

Page 13

MAN607-S

Framing error (?: 3F16)

If the input data cannot be printed correctly and instead “!” or “?” is printed, the transmission conditions between the host device and the PRN607-S most likely does not match. If this happens, adjust the conditions so that they match.

2.6.3 Thermal Head Control

Data Transfer to the Thermal Head

The PRN607-S transfers one dot line of data at 4 Mbps synchronized with the CLOCK signal.

The data is transferred in order to the shift register inside the thermal head from the left (when facing the paper feed direction).

The transferred data is then transferred by the head latch signal to the latch register inside the thermal head. Turning on the head strobe signal initiates printing of one dot line of data on the thermal paper.

2.6.4 Thermal Head Drive Operation

Generally, when the line thermal head is operating, the line is divided into several blocks, which are activated one after another in succession.

For the line thermal head of the FTP607MCLxxx printer mechanism, the line is divided into 3 blocks called physical blocks, 64 dots with each. A strobe signal (DST1 to DST3) is allocated to each physical block to activate it. To drive the head, physical blocks are activated in groups. The group of physical blocks is called a logical block.

For the PRN607-S either dynamic division or fixed division can be selected as the method of division for logical blocks. This selection is made through a function. See settings for more information.

2.6.5 Peak power limitation

The PRN607-S counts the number of dots activated in each physical block and groups the physical blocks into logical blocks to print a single dot line so that the number does not exceed the specified maximum number of activated dots. The PRN607-S determines logical blocks each time it prints a single dot line.

In dynamic division, in order to avoid unclear printing, at the first step of the motor the thermal head is driven and at the second step the paper is fed. Also, since the order of the printing blocks and printing speed are changed in each dot line according to the content of the print data, print quality may be lower than that in fixed division. If print quality is regarded as important, printing in fixed division is recommended.

The maximum number of activated dots in the initialisation status is specified using the function switches.

28-03-2003 Page 2-13 of 53

Image 13
Contents For Fujitsu Thermal Printers FTP607MCLXXX Series Copyright 1999-2003 by I/F-COM A/S All rights reserved Safety Precautions1-3 Specifications Function Maintenance APS Compatible Command SET FTP627MCLxxx FTP637MCLxxx InstallationUnpacking LabelsSettings Power supply2-9 2-10 Serial Input/Output 2-12 2-13 2-14 Specifications USB communication General Serial communicationIrda communication Auto form feed Firmware upgradeCharacter design 4-19 I/F-COM simple command set Printer commandsAscii ENQ Ascii EOTAscii ACK Ascii BELAscii DC1 Ascii DLEAscii DC3 Ascii DC2Ascii DC4 Ascii NAKAscii Can Ascii ETBAscii ESC Z Ascii SUBMAN607-S Automatic sending status Name Format FTP607MCLXXX 4-28 EAN13 UpcaEAN8 MAN607-S Code128 barcode table Black Mark Name Set black mark parameters Format D1,d2,..,dX Escape Sequences Ascii Function Store/Transport Daily useMechanical Data Electrical DataEnvironmental Data EMC & ESCTemperature Test Pin Function Connector Pin AssignmentPin Function +5V TBALED1+ LED2+ INPUT1 INPUT2 USB USB+ GND GND 24VDCPin GND CUT LEDDSR CTSMechanical Drawings Appendix Seiko compatible command setESC RS Fujitsu compatible command setESC US ESCCommand list description 7-45 7-46 ESC S APS compatible command setGS E 7-48 ESC FF ESC/POS compatible command setESC L 7-50 7-51 Bottom view Optional sensor description Top viewRED White Black