Framing error (?: 3F16)
If the input data cannot be printed correctly and instead “!” or “?” is printed, the transmission conditions between the host device and the
2.6.3 Thermal Head Control
Data Transfer to the Thermal Head
The
The data is transferred in order to the shift register inside the thermal head from the left (when facing the paper feed direction).
The transferred data is then transferred by the head latch signal to the latch register inside the thermal head. Turning on the head strobe signal initiates printing of one dot line of data on the thermal paper.
2.6.4 Thermal Head Drive Operation
Generally, when the line thermal head is operating, the line is divided into several blocks, which are activated one after another in succession.
For the line thermal head of the FTP607MCLxxx printer mechanism, the line is divided into 3 blocks called physical blocks, 64 dots with each. A strobe signal (DST1 to DST3) is allocated to each physical block to activate it. To drive the head, physical blocks are activated in groups. The group of physical blocks is called a logical block.
For the
2.6.5 Peak power limitation
The
In dynamic division, in order to avoid unclear printing, at the first step of the motor the thermal head is driven and at the second step the paper is fed. Also, since the order of the printing blocks and printing speed are changed in each dot line according to the content of the print data, print quality may be lower than that in fixed division. If print quality is regarded as important, printing in fixed division is recommended.
The maximum number of activated dots in the initialisation status is specified using the function switches.