EM78M611E
Universal Serial Bus Series Microcontroller
ERC (AD MSB Data Register) Default Value: (0B_0000_0000)
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
|
|
|
|
|
|
|
|
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
2 bits AD MSB Digital Data.
ERD (AD Control Register) Default Value: (0B_0000_0000)
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
|
|
|
|
|
|
|
|
0 | 0 | 0 | 0 | 0 | - | ADPS1 | ADPS0 |
|
|
|
|
|
|
|
|
ERD [0 1]: The clock source of AD converting time.
00:256kHz
01:128kHz
10:64kHz
11:32kHz
8.12EEPROM
Four bytes of EEPROM are located in the R2C~R2F of Bank 3. The stored data of EEPROM are not erased when the power is off and can be read and
A control register, ERA controls the EEPROM, that is, to read, write, or to erase the data from EEPROM. Writing a command into this register will execute an action to the EEPROM. The command value is defined in the following tale. Note that there is an execution time laps for each command. Before writing the next command into the control register, allow enough time for the EEPROM to finish the previous command.
Command Value | Action | Execution Time |
|
|
|
0B_0000_0000 | Read | 1 ms |
|
|
|
0B_0000_0001 | Write | 9 ms |
|
|
|
0B_0000_0010 | Erase | 128 ms |
|
|
|
0B_0000_0011 | Disable | N.A. |
|
|
|
Product Specification (V1.11) 04.20.2007 | • 31 |
(This specification is subject to change without further notice)