IBM 09-0572-000 manual Adapter Configuration Screen

Page 38

Changing Software Option Settings

4-7

7When the next screen appears, select Configuration and Diagnostic Program.

8Highlight Install and press [Enter].

9Press [Enter] to select Configure Adapter.

A screen similar to the one shown in Figure 4-3 appears.

Diagnostic and Manual Configuration Program

Quit Install Test View Select

Adapter Configuration

F1=Help

TokenLink III Adapter Configuration

Configuration Mode

3Com

 

 

l/O Base Address

A20h

 

 

Interrupt Request Level

3

 

 

 

 

 

Ring Speed

 

16

Mbps

 

 

BIOS/MMIO Base Address

CC000h

 

 

Shared RAM Address Range

D8000h - DBFFFh

 

 

Memory Mode

 

16

bit

 

 

I/O Mode

 

16

bit

 

 

IRQ Driver Type

Edge Triggered

 

 

Auto Switch

 

Enabled

 

 

Boot PROM

 

Enabled

 

 

 

 

 

 

 

 

 

 

 

 

Modify

File Options

 

OK

Cancel

[ENTER]=Change the Setting [−↓]=Scroll

[Alt]+<Highlighted Key>=Execute Function

Figure 4-3 Adapter Configuration Screen

10Use the arrow keys to highlight a desired parameter option and press [Enter].

A second dialog box appears.

11Use the arrow keys to scroll through the list of settings for that option. Select a setting and press [Enter].

12Continue this procedure with any of the other options.

13Press [Tab] three times to highlight <OK>. Press [Enter].

You must highlight <OK> and press [Enter] to save the new settings to the adapter.

Image 38
Contents ISA Adapter User Guide Member of the TokenLink III product familyLifetime Warranty Asia 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Contents Installing the Network Driver for Windows Troubleshooting Using the Configuration and Diagnostic Program Page Figures 3Com Mode versus IBM Mode TablesIntroduction How to Use This GuideAbout this Guide Install ConventionsTokenLink III 16/4 ISA Token Ring Adapter Features IntroductionInstallation and Configuration Options AutoLink InstallationAdapter Installation and Configuration Windows Installation and Configuration TroubleshootingStandard Installation and Configuration Transcend PC Link SmartAgent SoftwareMoney-Back Guarantee Installing the 3C619C Adapter3C619C Adapter Installation PC Requirements Taking Safety Precautions Inspecting the AdapterInstalling the Adapter Check the adapter for any visible signs of damageRemoving the Backplate RJ-45 Connecting to the NetworkShielded twisted-pair STP cable DB-9 Connecting to Shielded Twisted-pair STP Cable Locate the DB-9 connector on the shielded twisted-pair cableConnecting to Unshielded Twisted-pair UTP Cable Using the Auto Link Feature for NET WareAutoLink Requirements AutoLink OptionsMake a backup copy of the CONFIG.SYS file. Type Avoiding Memory Manager ConflictsType at the prompt Using the AutoLink FeatureFollow these steps to use the AutoLink feature Standard Installation ConfigurationConfiguration Requirements Auto Configuring the 3C619C Adapter in an ISA PCI N N U IRQ = 2,3,6, or Changing Software Option Settings IBMTo change the software option settings, follow these steps Adapter Configuration Screen Changing Settings for Multiple Adapters Video Conflicts with BIOS/MMIO and Shared RAM AddressesChanging Software Option Settings Installing Network DriversInstalling the Novell NetWare Driver DEC PATHWORKSMain Menu with Network Drivers Option Selected Updating the PC Startup Files NetWare Systems with Multiple Adapters Installing the OS/2 Network Driver for NetWareInstalling the Server Driver for NetWare Installing the Ndis 2.01 Driver Build a PROTOCOL.INI file in the Lanman subdirectory Sample PROTOCOL.INI File IBM modeNdis Systems with Multiple Adapters Obtaining IBM Network Drivers Using IBM DriversUpdating the Current Ndis Driver Using Remote Program Load RPL Before Using RPLEnabling RPL 3TOKDIAG Enter Driver for Windows Installing the NetworkInstalling the Network Driver for Windows NT Click the Continue buttonInstalling the Network Driver for Windows \WIN95 Troubleshooting Adapter LEDsUsing the TokenDisk Diskette Diagnostic Program Depicts how to use the TokenDisk diskette diagnostic program Diagnostic Test Types Group 1 DiagnosticsDiagnostic Test Types Group 2 Diagnostic Running the Diagnostic TestsTest Menu Changing the Test Setup File OptionsAdapter Statistics When Tests FailAdapter Statistics and Information When Tests Fail Adapter InformationAIP Checksum Test Failure Boot Prom Test FailureMmio Register Write/Read Test Failure Shared RAM Boundary/Domain Test FailureOpen Adapter for Ring Operation Test Failure Timer Test FailureShared RAM Write/Read Test Failure Ring Operations Test FailureAdapter Wrap Test Failure Group Troubleshooting TipsClose Adapter Test Failure Inspect all cables and connectionsRefer to Appendix B, Specifications On-line Information Error MessagesAdditional Information Technical SupportUsing Configuration Diagnostic Program Figure A-1 Menu HierarchyUsing the Keyboard Speed KeysUsing the Mouse Choosing a Menu ItemLoad loads a file from a selected directory Using the File OptionsHelp DOS prompt such as A\ type Using the Command LineExiting the Program Pin Assignments SpecificationsCabling Cabling Pin Assignments Configuration OptionsFigure B-1 DB-9 Connector Pin Assignments Configuration Mode Configuration OptionsRing Speed Base AddressBIOS/MMIO Address Location Shared RAM Page Size and Address RangeInterrupt Request Level KB / CE000-CFFFFOther Configuration Options Error Messages MessagesAppendix C Error Messages Messages C-3 Appendix C Error Messages Messages C-5 Technical Support On-line Technical Services3Com Bulletin Board Service Ask3Com on CompuServe 3ComFacts Automated Fax ServiceWorld Wide Web Site To use Ask3Com Log on to CompuServeSupport from Your Network Supplier Details about recent configuration changes, if applicableReturning Products for Repair To obtain an RMA number, call or faxGlossary Controlled access unit ConfigurationDual access unit Driver Lobe Multistation access unitIndustry Standard Architecture Protocol layers Token ringTSR Index NumericsNdis View A-3 RPL Limited Warranty FCC Class a Verification Statement

09-0572-000 specifications

The IBM 09-0572-000 is a notable component within IBM's broad range of technology solutions, particularly recognized for its integration in enterprise-level systems. This model is primarily distinguished as a power supply unit designed for IBM's well-established line of servers and storage solutions.

One of the key features of the IBM 09-0572-000 is its reliability under heavy workloads. This power supply is engineered to provide a stable power source, ensuring that systems remain operational during critical processes. It boasts robust protection mechanisms, including overvoltage, undervoltage, and overcurrent protection. These features are essential for safeguarding sensitive components in server environments, where power fluctuations could lead to data loss or hardware failure.

Moreover, the IBM 09-0572-000 supports hot-swapping capabilities, allowing IT administrators to replace the power supply without shutting down the system. This feature significantly enhances system availability and reduces downtime, which is crucial for businesses that rely on 24/7 operations.

In terms of performance, the power supply is designed to meet high-efficiency standards, with many models featuring an energy efficiency rating that complies with the 80 PLUS certification. This designation indicates that the power supply operates efficiently under various loads, translating into lower operational costs and reduced energy consumption for businesses.

The IBM 09-0572-000 is also compatible with multiple server configurations, showcasing its versatility within various IBM enterprise environments. This adaptability makes it an ideal choice not just for current models but also for legacy systems, highlighting its longevity in the tech lifecycle.

With a compact design, this power supply enables optimal space utilization within server racks. It exhibits a well-thought-out construction providing excellent thermal management, which is vital in preventing overheating in densely packed data centers.

Ultimately, the IBM 09-0572-000 epitomizes the combination of reliability, efficiency, and versatility that IBM products are known for. Its advanced protective features, compatibility with a range of systems, and innovative design make it a critical component for ensuring optimal performance and uptime in enterprise IT environments. Whether for small businesses or large-scale operations, the 09-0572-000 continues to be a staple in maintaining the heart of robust IT infrastructures.