Fujitsu D1241 manual SMBus Connector 5-1 pin SMB, NIC Activity LED 2-pin, Status LED 2-pin

Page 33

3.HARDWARE SETUP

16)SMBus Connector (5-1 pin SMB)

This connector allows you to connect SMBus (System Management Bus) de- vices. SMBus devices communicate by means of the SMBus with an SMBus host and/or other SMBus devices. SMBus is a specific implementation of an I2C bus, which is a multi-device bus; that is, multiple chips can be connected to the same bus and each one can act as a master by initiating data transfer.

CUR-DLS

+5V

SMBDATA Ground

SMBCLK 1

SMB

CUR-DLS SMBus Connector

The following PANEL illustration is used for items 17–26 (next page).

 

LEDPower+

activityNICLED–

PowerLED –

Key GND buttonNMI

+5V

accessHDDLED+

accessHDDLED–

Speaker

Pin

Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

&

12

NIC Activity LED

CUR-DLS

 

 

 

 

 

 

 

 

 

3

&

4

Status LED

 

11

 

 

 

 

 

 

 

20

4

&

5

SMI Lead

 

 

 

 

 

 

 

 

 

 

6

&

7*

Power Button

 

1

 

 

 

 

 

 

 

10

7* & 8

Chassis Intrusion

 

LED+activityNIC

LED+Status

LEDStatus–

buttonbuttton/sleep#

GND buttonPower

GND

intrudeChassis

buttonRESET

GND

9

&

10

Reset Switch

 

11 & 13

Power LED

 

 

 

 

 

 

 

 

 

 

15*

& 16

NMI Button

 

 

 

 

 

 

 

 

 

 

17 & 20

Speaker

 

 

 

 

 

 

 

 

 

 

18 & 19

HDD Access LED

 

 

 

 

 

 

 

 

 

 

* Shared

 

 

 

 

 

SMI#

 

 

 

 

 

 

 

 

 

CUR-DLS System Panel Connectors

17)NIC Activity LED (2-pin)

This shows the status of the NIC through a panel-mounted LED.

18)Status LED (2-pin)

This shows the system status as programmed through ASIC.

19)System Management Interrupt Lead (2-pin)

This allows the user to manually place the system into a suspend mode or “Green” mode where system activity will be instantly decreased to save electricity and expand the life of certain components when the system is not in use. This 2-pin connector (see the preceding figure) connects to the case-mounted suspend switch.

.3 SETUPH/W

Connectors

User’s Manual

29

Image 33
Contents Page Page Page A26361-D1241-Z120-1-7619 Page %!.-*!.+,/#/$%&&&1 Page Contents User’s Manual FCC & DOC Compliance Manual information and checklist Item ChecklistIntructions on setting up the Bios How This Manual Is OrganizedMotherboard SpecificationsLatest Intel Processor Support Scsi Type PCI1-4PCI/ISA Expansion Slots Specifications-Optional ComponentsPerformance Intelligence See opposite page for locations Motherboard ComponentsComponent Locations Hardware Setup Layout Contents Hardware SetupMotherboard Settings Hardware Setup ProcedureSystem Memory Dimm Sdram ConfigurationsCUR-DLS 168-Pin Dimm Sockets Dimm InstallationCPU Central Processing Unit CPUExpansion Cards Expansion Card Installation ProcedureISA Interrupt IRQ Assignments Assigning IRQs for Expansion CardsConnectors PS/2 Mouse Connector Green 6-pin PS2KBMSPS/2 Keyboard Connector Purple 6-pin PS2KBMS Fast-Ethernet Port Connector RJ45 optional Parallel Port Connector Burgundy 25-pin PrinterSerial Port Connectors Teal/Turquoise 9-pin COM1/COM2 USB Header 10-1 pin Usbport Monitor Output Connector Blue 15-pin VGAFloppy Disk Drive Connector 34-1 pin Floppy Primary Blue / Secondary IDE Connectors 40-1 pin IDE1/IDE2 Wake-On-Ring Connector 2-pin WOR Wake-On-LAN Connector 3-pin WolconCPU and Chassis Fan Connectors 3-pin CPUFAN1/2, CHAFAN1/2 NIC Activity LED 2-pin SMBus Connector 5-1 pin SMBStatus LED 2-pin System Management Interrupt Lead 2-pinReset Switch Lead 2-pin ATX Power Switch / Soft-Off Switch Lead 2-pinSystem Power LED Lead 3-1 pin System Warning Speaker Connector 4-pinTwo 68-pin Ultra160/Ultra2 Scsi Connectors ATX Power Supply Connector 20-pin block AtxpwrScsi Connection Notes Beep Meaning Starting Up the First TimePowering Up Upon First Use of the Computer System Managing and Updating Your BiosUpdating Bios Procedures Bios Setup Follow the onscreen instructions to continue Bios Setup Program Navigation Keys Function Description Bios Menu BarGeneral Help Main Menu Floppy 3 Mode Support DisabledSystem Time System Date XX/XX/XXXXNone to disable IDE devices Primary & Secondary Master/SlaveType Auto User Type HDD Translation Method LBACylinders PIO Mode Smart Monitoring DisabledUltra DMA Mode Disabled HeadBoot Up NumLock Status On Keyboard FeaturesKeyboard Auto-Repeat Delay 1/4 Sec Other options for Type areForgot the Password? Supervisor Password Disabled / User Password DisabledHalt On All Errors Installed Memory XXX MBCPU Level 2 Cache ECC Check Disabled CPU Level 1 Cache, CPU Level 2 Cache EnabledProcessor Serial Number Disabled Bios Update EnabledPS/2 Mouse Function Control Auto OS/2 Onboard Memory 64M DisabledVideo Memory Cache Mode UC Chip ConfigurationMemory Hole At 15M-16M Disabled High Priority PCI Mode EnabledFloppy Disk Access Control R/W 2 I/O Device ConfigurationUART2 Use Standard Infrared Disabled Onboard FDC Swap a & B No SwapParallel Port Mode ECP+EPP Onboard Parallel Port 378H/IRQ7ECP DMA Select PCI/VGA Palette Snoop Disabled PCI ConfigurationPCI Latency Timer Onboard Scsi Bios AutoONB Primary Scsi Term, ONB Secondary Scsi Term Enabled ONB Scsi Bios First NoUSB Function Enabled ONB VGA Bios First NoShadow Configuration Video ROM Bios Shadow EnabledC8000-DFFFF Shadow Disabled Power Management User Define Power MenuHDD Power Down Disabled Video Off Option Suspend OffVideo Off Method Dpms OFF AC PWR Loss Restart Disabled Power Up ControlPWR Up On Modem Act Enabled Wake On LAN DisabledAutomatic Power Up Disabled Hardware Monitor Boot Device Boot MenuOther Boot Device Select INT18 Device Network Removable Device Legacy FloppyQuick Power On Self Test Enabled MPS 1.4 Support EnabledBoot Up Floppy Seek Disabled Full Screen Logo EnabledExit Saving Changes Exit MenuLoad Setup Defaults Glossary Dram Dynamic Random Access Memory BootBus Master IDE Byte Binary TermPost Power On Self Test Plug and Play BiosLPT Port Line Printer Port OnNowScsi Small Computer System Interface ROM Read Only MemorySdram Synchronous Dram SPD for Sdram moduleHinweise zum vorliegenden Dokument Information on this document

D1241 specifications

The Fujitsu D1241 is a high-performance server motherboard designed to cater to the demands of various applications, particularly in enterprise environments. It supports advanced computing requirements while providing flexibility and reliability that organizations require to thrive in a competitive landscape.

One of the standout features of the Fujitsu D1241 is its support for the latest Intel Xeon processors. This enables the motherboard to deliver exceptional processing power, making it suitable for data-intensive workloads such as virtualization, database management, or high-performance computing. With multiple CPU configurations, organizations can easily scale their performance needs based on their workloads.

The D1241 is equipped with robust memory support, allowing it to handle up to 1TB of DDR4 ECC RAM across its DIMM slots. This capability is crucial for mission-critical applications where data integrity and reliability are paramount. The use of Error-Correcting Code (ECC) technology helps identify and correct memory errors automatically, thereby minimizing system downtime and enhancing overall system stability.

In terms of connectivity, the Fujitsu D1241 features multiple PCIe slots that enable organizations to incorporate additional components, such as GPUs, RAID controllers, or network interface cards. This expandability ensures that businesses can customize their systems to meet their specific requirements. Furthermore, it includes multiple SATA and NVMe ports, which allow for fast storage solutions, enhancing data retrieval and processing speeds.

Security is another critical aspect of the Fujitsu D1241. The motherboard is designed with advanced security features, including firmware and hardware-based security measures, to protect sensitive data against unauthorized access. This capability is essential for businesses that handle confidential information and need to comply with industry regulations.

Cooling and power efficiency are also prioritized in the design of the D1241. The motherboard supports advanced thermal management technologies, ensuring optimal system performance even under heavy loads. Combined with a power-efficient design, the D1241 helps organizations reduce energy costs while maintaining performance.

Overall, the Fujitsu D1241 stands out as a versatile and robust motherboard, combining cutting-edge technology, expandability, and reliability. Its enterprise-grade features make it a preferred choice for businesses looking to invest in a dependable server platform that can adapt to evolving technological demands. With its rich feature set, the D1241 proves to be an excellent foundation for a wide range of applications.