Additonal Sense Code

This is a 1-byte code displayed in the sense data and is information which specifies the type of error that was detected.

CCS

Common Command Set

This is the standard form of SCSI logical specifications stipulated by the operations subcommittee of the American National Standards Institute (ANSI) which stipulates functions which a direct access device (magnetic disk, etc.) should support.

CDB

Command Descriptor Block

A series of data which describes commands related to input/output operations, sent from the initiator to the target.

Command

This is a command to a target to perform an input/output operation, and it is described as the CDB.

Device

The general name given to a device which is connected to the fibre channel loop. (input/output device, I/O controller, host adapter, etc.).

Initiator

This is a device which initiates input and output operations on the fibre channel loop.

SCSI

Small Computer System Interface

The standardized input/output interface of the American National Standards Institute (ANSI). [Standard No.: ANSI X3. 131-1986]

Sense Data

When several items of error information are included in a command's completion status, this is information generated by the target for reporting detailed information on that status.

Sense Key

This is a 4-bit code displayed in the sense data. It contains information for classifying the type of error that was detected.

Status

This is 1 byte of information reported to the initiator by the target device when execution of each command is completed, which displays the command's completion state.

C141-E235

GL-1

Image 101
Contents C141-E235-01EN For Safe Operation C141-E235 This page is intentionally left blank Revision Record Fibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Arbitrated Loop FC-AL Fibre Channel Protocol for Scsi SCSI-FCPOverview of Manual PrefaceConventions for Alert Messages PrefaceC141-E235 Iii This page is intentionally left blank Important Alert Messages Important Alert ItemsImportant Alert Items C141-E235 Vii This page is intentionally left blank Specifications Maintenance ManualManual Organization Product Fibre ChannelThis page is intentionally left blank Contents Contents InstallationAppendix a Figures Tables This page is intentionally left blank General Description Standard Features Hardware Structure System ConfigurationGeneral Description Standard FeaturesStandard Features General Description FC model drives outer view Hardware StructureGeneral Description Example of FC-AL system configuration System ConfigurationThis page is intentionally left blank Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number Function specifications SpecificationsHardware Specifications Environmental/power requirements Environmental specificationsReliability Error rateMtbf = Hardware Specifications This page is intentionally left blank Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management SA0 Data FormatData Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements External dimensions Installation RequirementsDimensions Installation RequirementsMounting orientations Mounting RequirementsMounting frame structure Limitation of side-mounting MPU Surface temperature check pointHDC Service clearance area MAW3300FC MAW3147FC MAW3073FC Connection Requirements Connector location10 SCA2 type connector Interface connectorInstallation Installation Setting Loop ID setting SettingMode settings Motor start modeMounting Drives Mounting procedures C141-E235 Checking connection Checking the HDD connection a Checking the HDD connection B Formatting Installation Setting parameters Arre AwreArre Awre PER Xxxx DiscXffff Commands is Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Precautions Maintenance InformationMaintenance requirements Maintenance levels Revision label example Revision numbersTests Indicating revision numbers Tools and test equipmentTest flowchart Operation Check Diagnostic testOperation Check Initial seek operation check Operation testTroubleshooting with disk drive replacement in the field System-level field troubleshooting Troubleshooting ProceduresDisk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting ProceduresTroubleshooting with parts replacement in the factory This page is intentionally left blank Error Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorInterface FC-SCA Connector Signal Allocation Appendix a Connector Signal AllocationConnector Signal Allocation Glossary Target Targ GlossaryAcronyms and Abbreviations OEM Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADC141-E235 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank
Related manuals
Manual 1 pages 9.53 Kb

MAW3073fc, MAW3147FC, MAW3300FC specifications

The Fujitsu MAW3073fc, MAW3300FC, and MAW3147FC are high-performance Fibre Channel hard disk drives that cater to enterprise storage solutions. Designed for demanding applications, these drives are engineered to deliver reliability, speed, and capacity, making them suitable for data centers and other high-availability environments.

The MAW3073fc offers a storage capacity of 73GB and operates at 15,000 RPM, ensuring rapid data access and high throughput. This drive features advanced error correction capabilities, enhancing data integrity while minimizing downtime. The MAW3073fc supports the Fibre Channel interface, enabling fast data transfer rates that are essential for high-performance computing scenarios.

Following this, the MAW3300FC steps up the game with a larger capacity of 300GB, also spinning at 15,000 RPM. It boasts enhanced reliability features, including improved thermal management and vibration tolerance, which significantly reduce wear and tear and prolong the drives' lifespan. Its hot-swappable design allows for easy maintenance, making it an ideal choice for critical applications that require minimal disruptions.

The MAW3147FC further expands the offering with a storage capacity of 147GB. Designed for applications that require a balance between performance and capacity, this drive provides a reliable solution for enterprise environments. Like its counterparts, it operates at 15,000 RPM, ensuring swift data retrieval and consistency under heavy loads. The MAW3147FC also implements sophisticated caching algorithms that optimize read and write performance.

All three drives utilize SCSI command sets and feature RAID support, making them compatible with various enterprise storage systems. These drives are built with enterprise-grade components, ensuring durability and reliability, crucial in mission-critical setups. The combination of high RPM speeds, reliability features, and large capacities makes the Fujitsu MAW series an excellent choice for organizations looking to enhance their storage infrastructure.

In terms of technologies, these drives use advanced servo technology and tight mechanical tolerances to achieve high precision and performance. Moreover, they are designed to operate in environments with rigorous temperature and humidity controls, further enhancing their reliability. The MAW series exemplifies Fujitsu's commitment to providing high-quality, performance-driven storage solutions for modern enterprise needs.