Fujitsu MAW3073fc, MAW3300FC, MAW3147FC manual Preface, Conventions for Alert Messages

Page 8

Preface

APPENDIX A Connector Signal Allocation

The appendix gives supplementary information, including the signal assignments of interface connectors.

CONVENTIONS USED IN THIS MANUAL

The MAW3300FC, MAW3147FC, and MAW3073FC disk drives are described as "the hard disk drive (HDD)", "the disk drive" or "the device" in this manual.

Decimal number is represented normally.

Hexadecimal number is represented as X'17B9', 17B9h or 17B9H.

Binary number is represented as "010".

Conventions for Alert Messages

This manual uses the following conventions to show the alert messages. An alert message consists of an alert signal and alert statements. The alert signal consists of an alert symbol and a signal word or just a signal word.

The following are the alert signals and their meanings:

This indicates a hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. This alert signal also indicates that damages to the product or other property, may occur if the user does not perform the product correctly.

This indicates information that could help the user use the product more efficiently.

In the text, the alert signal is centered, followed below by the indented message. A wider line space precedes and follows the alert message to show where the alert message begins and ends. The following is an example:

(Example)

Damage

Never remove any labels from the drive or deface them in any way.

The main alert messages in the text are also listed in the “Important Alert Items.”

ii

C141-E235

Image 8
Contents C141-E235-01EN For Safe Operation C141-E235 This page is intentionally left blank Revision Record Fibre Channel Physical and Signaling Interface FC-PH Fibre Channel Physical and Signaling INTERFACE-2 FC-PH-2Fibre Channel Arbitrated Loop FC-AL Fibre Channel Protocol for Scsi SCSI-FCPPreface Overview of ManualPreface Conventions for Alert MessagesC141-E235 Iii This page is intentionally left blank Important Alert Items Important Alert MessagesImportant Alert Items C141-E235 Vii This page is intentionally left blank Maintenance Manual SpecificationsManual Organization Product Fibre ChannelThis page is intentionally left blank Contents Installation ContentsAppendix a Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration General DescriptionStandard Features General DescriptionStandard Features General Description Hardware Structure FC model drives outer viewGeneral Description System Configuration Example of FC-AL system configurationThis page is intentionally left blank Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number Specifications Function specificationsHardware Specifications Environmental specifications Environmental/power requirementsError rate ReliabilityMtbf = Hardware Specifications This page is intentionally left blank Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management Data Format SA0Data Space Alternate spare area Spare area in cellTrack format Track skew/head skew Sector formatData Space Format capacity Logical Data Block Addressing Defect Management Defect list Alternate block allocationAlternate block allocation by Format Unit command Defect ManagementAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Installation Requirements Mounting Requirements External dimensionsInstallation Requirements DimensionsMounting Requirements Mounting orientationsMounting frame structure Limitation of side-mounting MPU Surface temperature check pointHDC Service clearance area MAW3300FC MAW3147FC MAW3073FC Connector location Connection RequirementsInterface connector 10 SCA2 type connectorInstallation Installation Setting Setting Loop ID settingMode settings Motor start modeMounting Drives Mounting procedures C141-E235 Checking connection Checking the HDD connection a Checking the HDD connection B Formatting Installation Setting parameters Awre ArreArre Awre PER Xxxx DiscXffff Commands is Dismounting Drives Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Maintenance Information PrecautionsMaintenance requirements Maintenance levels Revision numbers Revision label exampleIndicating revision numbers Tools and test equipment TestsTest flowchart Diagnostic test Operation CheckOperation Check Initial seek operation check Operation testTroubleshooting with disk drive replacement in the field Troubleshooting Procedures System-level field troubleshootingTroubleshooting at the repair site Disk drive troubleshootingFinding possibly faulty parts Troubleshooting ProceduresTroubleshooting with parts replacement in the factory This page is intentionally left blank Error Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataError Analysis ILILSB SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxAppendix a Connector Signal Allocation Interface FC-SCA Connector Signal AllocationConnector Signal Allocation Glossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations OEMBcrc ECCMode SELECT/MODE Select IndexMtbf Mttr PADC141-E235 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank
Related manuals
Manual 1 pages 9.53 Kb

MAW3073fc, MAW3147FC, MAW3300FC specifications

The Fujitsu MAW3073fc, MAW3300FC, and MAW3147FC are high-performance Fibre Channel hard disk drives that cater to enterprise storage solutions. Designed for demanding applications, these drives are engineered to deliver reliability, speed, and capacity, making them suitable for data centers and other high-availability environments.

The MAW3073fc offers a storage capacity of 73GB and operates at 15,000 RPM, ensuring rapid data access and high throughput. This drive features advanced error correction capabilities, enhancing data integrity while minimizing downtime. The MAW3073fc supports the Fibre Channel interface, enabling fast data transfer rates that are essential for high-performance computing scenarios.

Following this, the MAW3300FC steps up the game with a larger capacity of 300GB, also spinning at 15,000 RPM. It boasts enhanced reliability features, including improved thermal management and vibration tolerance, which significantly reduce wear and tear and prolong the drives' lifespan. Its hot-swappable design allows for easy maintenance, making it an ideal choice for critical applications that require minimal disruptions.

The MAW3147FC further expands the offering with a storage capacity of 147GB. Designed for applications that require a balance between performance and capacity, this drive provides a reliable solution for enterprise environments. Like its counterparts, it operates at 15,000 RPM, ensuring swift data retrieval and consistency under heavy loads. The MAW3147FC also implements sophisticated caching algorithms that optimize read and write performance.

All three drives utilize SCSI command sets and feature RAID support, making them compatible with various enterprise storage systems. These drives are built with enterprise-grade components, ensuring durability and reliability, crucial in mission-critical setups. The combination of high RPM speeds, reliability features, and large capacities makes the Fujitsu MAW series an excellent choice for organizations looking to enhance their storage infrastructure.

In terms of technologies, these drives use advanced servo technology and tight mechanical tolerances to achieve high precision and performance. Moreover, they are designed to operate in environments with rigorous temperature and humidity controls, further enhancing their reliability. The MAW series exemplifies Fujitsu's commitment to providing high-quality, performance-driven storage solutions for modern enterprise needs.