Fujitsu MAW3073NC/NP, MAW3300NC/NP, MAW3147NC/NP manual Scsi ID

Page 118

A.1 Setting Terminals (on NP model only)

 

 

 

Table A.1

CN2 setting terminal (on NP model drives only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting item

 

 

 

 

 

Pin pair

 

 

 

 

 

 

 

Setting contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - 2

 

3 - 4

5 - 6

7 - 8

 

9 - 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI ID

 

Open

 

 

Open

Open

 

(Open)

 

 

 

SCSI ID #0

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Open

 

(Open)

 

 

 

SCSI ID #1

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Open

 

(Open)

 

 

 

SCSI ID #2

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Open

 

(Open)

 

 

 

SCSI ID #3

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Open

Short

 

(Open)

 

 

 

SCSI ID #4

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Short

 

(Open)

 

 

 

SCSI ID #5

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Short

 

(Open)

 

 

 

SCSI ID #6

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Short

 

(Open)

 

 

 

SCSI ID #7

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Open

Open

 

Short

 

 

 

SCSI ID #8

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Open

 

Short

 

 

 

SCSI ID #9

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Open

 

Short

 

 

 

SCSI ID #10

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Open

 

Short

 

 

 

SCSI ID #11

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Open

Short

 

Short

 

 

 

SCSI ID #12

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Short

 

Short

 

 

 

SCSI ID #13

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Short

 

Short

 

 

 

SCSI ID #14

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Short

 

Short

 

 

 

SCSI ID #15

(16-bit SCSI only) (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write protect

 

 

 

 

 

 

 

 

 

 

 

 

Open

Write operation is enabled. (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

Write operation is disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting item

 

 

 

 

 

Pin pair

 

 

 

 

Setting contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 - 12

13 - 14

15 - 16

23 - 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor start mode

 

 

 

Open

 

 

 

 

 

 

 

 

 

 

Started by the START/STOP command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

 

 

 

 

 

 

 

 

Started by turning the power supply on (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force Narrow

 

 

 

 

 

 

Open

 

 

 

 

 

 

Width of 16-bit bus (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

 

 

 

 

Width of 8-bit bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force Single Ended

 

 

 

 

 

 

 

 

Open

 

 

 

Follows DIFFSNS signal level on SCSI bus (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

 

Single-Ended mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminating power supply

 

 

 

 

 

 

 

 

 

Open

Does not supply terminating resistor power to SCSI BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

Supply terminating resistor power to SCSI BUS (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Setting at factory shipment

Note:

See the description of Section 5.3 for details of the setting requirements and notes.

A-2

C141-E226

Image 118
Contents C141-E226-01EN For Safe Operation Revision Record Related Standards Preface General DescriptionConventions Used in this Manual Important Alert Items Important Alert MessagesTask Alert message Installation Manual Organization Product MaintenanceManual This page is intentionally left blank Contents Installation Appendix B Connector Signal Allocation IN-1Figures Page Tables Standard Features Hardware Structure System Configuration General DescriptionStandard Features C141-E226 C141-E226 Page NC model drives outer view Page HDD Scsi ID LUNThis page is intentionally left blank Hardware Specifications Model name and order number SpecificationsHardware Specifications Scsi Function Specifications Model names and order numbers32/34 Meeprml Function specificationsMAW3300NC/NP MAW3147NC/NP MAW3073NC/NP ScsiPage Environmental specifications Environmental/power requirementsReliability Error rateMtbf = Page Shows the Scsi functions provided with the HDD This page is intentionally left blank Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Format Data SpaceSA0 Alternate spare area Spare area in cell Track format Track skew/head skew Sector formatPage Format capacity MAW3300NC/NPPage Defect Management Defect list Alternate block allocationPage Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format UnitC141-E226 This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsNC model dimensions NP model dimensions Mounting orientations HDD orientationsMounting frame structure HDC Surface temperature check pointMPU Surface temperature measurement points Spin-up current waveform +12V DC 10 Power on/off sequence Delay time of spindle motor starting 13 NC connectors location 14 SCA2 type 16-bit Scsi connector 2 68-pin connector type 16-bit Scsi model NP model 15 NP connectors and terminals location16 68-pin type 16-bit Scsi interface connector GND EsidLED WTP20 16-bit Scsi ID external input 74LS06 or equivalent 150 Ω CN1-A2 21 Output signal for external LED 22 Scsi cables connection Cable connector requirements Recommended components for connectionGND LED External operator panel on NP model drives onlyLED ID0 ID1 ID2 ID3 C141-E226 Installation Page Connections Scsi bus connections 1 CN2 CN2 setting terminal on NP models only Scsi ID setting Scsi ID #15Scsi Setting Scsi terminator power supply NP model Each mode settingMotor start mode setting Setting the bus width of the Scsi interface NP model Write protect setting NP modelSetting of the Scsi interface operation mode NP model GND/WTPDefault mode settings by Change Definition command Mode settingsSCSI-3 Mounting procedures Setting check list NP model onlyMounting Drives Check before mounting Connecting Cables Remark Checking Scsi connection Checking the Scsi connection a Checking the Scsi connection B Formatting Page Setting parameters Awre ArreArre Awre PER Xffff DiscXxxx Read/write This page is intentionally left blank Diagnostics Self-diagnostics Diagnostics and MaintenanceSelf-diagnostic functions Page Operation of self-diagnostics Test programs Maintenance Information Precautions Maintenance requirements Maintenance levels Revision numbers Revision label exampleIndicating revision numbers Tools and test equipment TestsTest flowchart Operation Check Initial seek operation check Diagnostic testOperation test Troubleshooting with disk drive replacement in the field System-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsThis page is intentionally left blank Error Analysis Information Collection Sense Data Analysis Error AnalysisError Analysis Information Collection Sense data MSB ILILSB SksvError information indicated with sense data Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxAppendix a Setting Terminals Setting Terminals on NP model onlyScsi ID Appendix B Connector Signal Allocation Diffsns Pcrca GND Diffsns Termpwr DBP1GND ATN BSY ACK RST MSG SEL REQ This page is intentionally left blank CN1 IndexECC Mode SELECT/MODE Select PADScsi connector B-3 Scsi connector signal allocation This page is intentionally left blank MAW3300NC/NP, MAW3147NC/NP, MAW3073NC/NP Hard Disk Drives PRODUCT/MAINTENANCE ManualJapan This page is intentionally left blankw
Related manuals
Manual 2 pages 16.03 Kb

MAW3147NC/NP, MAW3073NC/NP, MAW3300NC/NP specifications

Fujitsu has established itself as a key player in the world of hard disk drives, and their MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP models showcase exemplary engineering and innovative technology. These drives are designed primarily for enterprise applications, providing robust performance, reliability, and data integrity in demanding environments.

One of the standout features of the Fujitsu MAW series is its high storage capacity. The MAW3073NC/NP model comes with a generous 73 GB capacity, while the MAW3300NC/NP boasts 300 GB, and the MAW3147NC/NP offers 147 GB of storage. This range makes them suitable for various applications, from databases to data-intensive software.

The drives utilize the latest Serial Attached SCSI (SAS) interface, which ensures high speed and efficiency in data transfer. SAS technology provides better bandwidth and performance compared to older parallel SCSI interfaces, enabling faster access to data and improved overall system responsiveness. With rotational speeds of 10,000 RPM, these drives further enhance performance, enabling faster read and write times, which is critical for enterprise applications that require quick data retrieval.

Another noteworthy characteristic of the Fujitsu MAW series is their advanced error recovery and data integrity features. The drives are equipped with sophisticated error correction mechanisms and management systems that help maintain data integrity, ensuring that the data remains intact even in the event of power loss or system failure. This reliability is paramount for enterprise environments where data loss can result in significant operational disruptions.

In terms of physical design, these drives are built to endure the rigors of high-demand environments. They feature a robust construction that allows for efficient heat dissipation, minimizing the risks associated with overheating. Additionally, their form factor is designed for easy integration into various server and storage systems, making them versatile solutions for IT infrastructure.

Fujitsu's commitment to sustainability is also evident in the MAW series with their energy-efficient operation and reduced power consumption, contributing to decreased overall operational costs. With a combination of high performance, reliability, and sustainability, the Fujitsu MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP hard drives stand out as formidable choices for organizations looking to optimize their data storage solutions. They embody the cutting-edge technology and quality that Fujitsu is known for in the enterprise storage market.