Fujitsu MAW3147NC/NP manual Each mode setting, Setting Scsi terminator power supply NP model

Page 80

5.3.2Each mode setting

(1)Setting terminator power supply

Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminator power source (TERMPOW).

For information on NP model, refer to Figures 5.2 and 5.3.

Table 5.2 Setting SCSI terminator power supply (NP model)

Supply on/off of SCSI terminator power

Pin pair 23/24 of CN2

from the HDD

(TRMPOW/TRMPOW)

 

 

Supply off

Open

 

 

Supply on

Short (*1)

 

 

*1. Set at factory shipment.

 

For NC model, the function of the terminator power supply setting is not supported.

(2)Motor start mode

Set how to control the starting of the HDD spindle motor according to Table 5.3. This setting only determines the operation mode when the power supply is turned on or the microcode is downloaded. In both modes, stopping or restarting the spindle motor can be controlled by specifying the START/STOP UNIT command.

Table 5.3 Motor start mode setting

 

NC model (*3)

NP model

Start timing of the spindle motor

 

 

 

Pin 38 of CN1

Pin 78 of CN1

Pin pair 11/12 of

 

CN2

 

(RMT START)

(DYLD START)

 

(GND/RMSTART)

 

 

 

Starting of the motor is controlled

 

 

 

with the START/STOP UNIT

Short

Open or Short

Open

command.

 

 

 

The motor is started immediately after

 

 

 

the power supply is turned on or after

Open

Open

Short (*1)

the microcode is downloaded.

 

 

 

The motor is started after the elapse

 

 

 

of a delay time that is based on the

 

 

 

SCSI ID. The delay time is provided

Open

Short

(*2)

immediately after the power supply is

 

 

 

turned on or after the microprogram is

 

 

 

downloaded.

 

 

 

*1. Set at factory shipment.

*2. For NP model, delay starting of spindle motor is supported by the CHANGE DEFINITION command only.

*3. To set the setting terminals on NC models to short, apply voltage ranging between-0.3 V and 0.8 V to the setting terminals externally. To set the setting terminals on NC models to open, apply voltage ranging between 2.0 V and 5.5 V to the setting terminals from an external source.

Refer to Subsection 3.1.10 “START/STOP UNIT (1B)” of the SCSI Logical Interface Specifications for details of the START/STOP UNIT command.

5-8

C141-E226

Image 80
Contents C141-E226-01EN For Safe Operation Revision Record Related Standards Preface General DescriptionConventions Used in this Manual Important Alert Items Important Alert MessagesTask Alert message Installation Manual MaintenanceManual Organization Product This page is intentionally left blank Contents Installation Appendix B Connector Signal Allocation IN-1Figures Page Tables Standard Features Hardware Structure System Configuration General DescriptionStandard Features C141-E226 C141-E226 Page NC model drives outer view Page HDD Scsi ID LUNThis page is intentionally left blank Specifications Hardware Specifications Scsi Function SpecificationsHardware Specifications Model name and order number Model names and order numbersFunction specifications MAW3300NC/NP MAW3147NC/NP MAW3073NC/NP32/34 Meeprml ScsiPage Environmental specifications Environmental/power requirementsMtbf = Error rateReliability Page Shows the Scsi functions provided with the HDD This page is intentionally left blank Cylinder configuration Data FormatData Space Logical Data Block Addressing Defect Management Data SpaceSA0 Alternate spare area Spare area in cell Track format Track skew/head skew Sector formatPage Format capacity MAW3300NC/NPPage Defect Management Defect list Alternate block allocationPage Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format UnitC141-E226 This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsNC model dimensions NP model dimensions Mounting orientations HDD orientationsMounting frame structure MPU Surface temperature check pointHDC Surface temperature measurement points Spin-up current waveform +12V DC 10 Power on/off sequence Delay time of spindle motor starting 13 NC connectors location 14 SCA2 type 16-bit Scsi connector 2 68-pin connector type 16-bit Scsi model NP model 15 NP connectors and terminals location16 68-pin type 16-bit Scsi interface connector Esid LEDGND WTP20 16-bit Scsi ID external input 74LS06 or equivalent 150 Ω CN1-A2 21 Output signal for external LED 22 Scsi cables connection Cable connector requirements Recommended components for connectionLED ID0 ID1 ID2 ID3 External operator panel on NP model drives onlyGND LED C141-E226 Installation Page Connections Scsi bus connections 1 CN2 CN2 setting terminal on NP models only Scsi ID setting Scsi ID #15Scsi Motor start mode setting Each mode settingSetting Scsi terminator power supply NP model Write protect setting NP model Setting of the Scsi interface operation mode NP modelSetting the bus width of the Scsi interface NP model GND/WTPSCSI-3 Mode settingsDefault mode settings by Change Definition command Mounting Drives Check before mounting Setting check list NP model onlyMounting procedures Connecting Cables Remark Checking Scsi connection Checking the Scsi connection a Checking the Scsi connection B Formatting Page Setting parameters Awre ArreArre Awre PER Xxxx DiscXffff Read/write This page is intentionally left blank Self-diagnostic functions Diagnostics and MaintenanceDiagnostics Self-diagnostics Page Operation of self-diagnostics Test programs Maintenance Information Precautions Maintenance requirements Maintenance levels Revision numbers Revision label exampleIndicating revision numbers Tools and test equipment TestsTest flowchart Operation test Diagnostic testOperation Check Initial seek operation check Troubleshooting with disk drive replacement in the field System-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsThis page is intentionally left blank Error Analysis Information Collection Sense data Error AnalysisError Analysis Information Collection Sense Data Analysis ILI LSBMSB SksvError information indicated with sense data Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxAppendix a Setting Terminals Setting Terminals on NP model onlyScsi ID Appendix B Connector Signal Allocation Diffsns GND ATN BSY ACK RST MSG SEL REQ DBP1Pcrca GND Diffsns Termpwr This page is intentionally left blank ECC IndexCN1 Mode SELECT/MODE Select PADScsi connector B-3 Scsi connector signal allocation This page is intentionally left blank Japan Hard Disk Drives PRODUCT/MAINTENANCE ManualMAW3300NC/NP, MAW3147NC/NP, MAW3073NC/NP This page is intentionally left blankw
Related manuals
Manual 2 pages 16.03 Kb

MAW3147NC/NP, MAW3073NC/NP, MAW3300NC/NP specifications

Fujitsu has established itself as a key player in the world of hard disk drives, and their MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP models showcase exemplary engineering and innovative technology. These drives are designed primarily for enterprise applications, providing robust performance, reliability, and data integrity in demanding environments.

One of the standout features of the Fujitsu MAW series is its high storage capacity. The MAW3073NC/NP model comes with a generous 73 GB capacity, while the MAW3300NC/NP boasts 300 GB, and the MAW3147NC/NP offers 147 GB of storage. This range makes them suitable for various applications, from databases to data-intensive software.

The drives utilize the latest Serial Attached SCSI (SAS) interface, which ensures high speed and efficiency in data transfer. SAS technology provides better bandwidth and performance compared to older parallel SCSI interfaces, enabling faster access to data and improved overall system responsiveness. With rotational speeds of 10,000 RPM, these drives further enhance performance, enabling faster read and write times, which is critical for enterprise applications that require quick data retrieval.

Another noteworthy characteristic of the Fujitsu MAW series is their advanced error recovery and data integrity features. The drives are equipped with sophisticated error correction mechanisms and management systems that help maintain data integrity, ensuring that the data remains intact even in the event of power loss or system failure. This reliability is paramount for enterprise environments where data loss can result in significant operational disruptions.

In terms of physical design, these drives are built to endure the rigors of high-demand environments. They feature a robust construction that allows for efficient heat dissipation, minimizing the risks associated with overheating. Additionally, their form factor is designed for easy integration into various server and storage systems, making them versatile solutions for IT infrastructure.

Fujitsu's commitment to sustainability is also evident in the MAW series with their energy-efficient operation and reduced power consumption, contributing to decreased overall operational costs. With a combination of high performance, reliability, and sustainability, the Fujitsu MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP hard drives stand out as formidable choices for organizations looking to optimize their data storage solutions. They embody the cutting-edge technology and quality that Fujitsu is known for in the enterprise storage market.