Fujitsu MB2142-03 manual Parallel Communications Adapter Specifications

Page 12

CHAPTER 1 HANDLING AND SPECIFICATIONS OF THE PRODUCT

1.2Parallel Communications Adapter Specifications

Table 1.2-1"Parallel Communications Adapter Specifications" lists the specifications of the parallel communications adapter.

Parallel Communications Adapter Specifications

Table 1.2-1"Parallel Communications Adapter Specifications" lists the specifications of the parallel communications adapter.

Table 1.2-1 Parallel Communications Adapter Specifications

Item

Contents

 

 

Name

Parallel communications adaptor

 

 

Model

MB2142-03

 

 

Power supply

Voltage: +5 V plus or minus 5% Current: 1A (max.) *1

Operating

0 to +55 degrees Celsius

temperature

 

 

 

Operating humidity

30% to 80% (non-condensing)

 

 

Dimensions

120mm (W) x 90mm (D) x 26mm (H) *2

Weight

200g approx.

 

 

*1: Power is supplied from the main unit.

*2: Not including projections.

Parallel Communications Specifications

The parallel communications format conforms to the Centronics interface.

An Amphenol 36P connector is used as the parallel communications connector.

The electrical characteristics of the I/O signal lines are described in Section 1.2.1 "Electrical Characteristics of I/O Signal Lines"

4

Image 12
Contents F2MC Family Page Fujitsu Limited Page Objectives and Intended Readers Structure of This ManualPage Contents Page Handling and Specifications of the Product Packing List Appearance and Names of PartsPacking List 1 Parallel Communications AdapterParallel Communications Adapter Specifications Parallel Communications Adapter Specifications1 Parallel Communications Adapter Specifications Contents Parallel Communications SpecificationsElectrical Characteristics of I/O Signal Lines Electrical Characteristics of I/O Signal LinesConnector Pin Assignment Connector Pin AssignmentGND If Cable Specifications If Cable Specifications2 if Cable General Specifications Contents 1 if Cable Components Part Name Remarks1 if Cable Dimensions 1 Storage Environment Storage temperature Storage humidity StorageCONNECTlONS System Configuration System ConfigurationCONNECTlONS Connection to Main Unit Connection to Main Unit1 if Cable Connection Connection to Host Machine Connection to Host Machine1 Printer Cable Connection Power-on Sequence Power-on SequencePower-off Sequence Power-off SequenceIndex Index Fujitsu Semiconductor Controller Manual