Fujitsu MB3887 manual Batt

Page 27

MB3887

Conversion efficiency vs. Charge current

Conversion efficiency vs. Charge current

(Constant voltage mode)

(Constant current mode)

Conversion efficiency η (%)

100

98

96

94

92

90

88

86

84

82

80

10 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

η (%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

efficiency

 

 

 

 

 

 

 

Ta = +25 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIN = 19 V

 

 

 

 

 

 

 

Conversion

 

 

 

 

 

 

 

BATT charge voltage =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

set at 16.8 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW = ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency η (%)

=

 

 

 

 

 

 

 

 

 

 

 

 

 

(VBATT IBATT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/

(VIN IIN) 100

 

 

 

100 m

1

 

 

10

 

100

98

96

94

92

90

88

86

84

82

80

0

Ta = +25 °C

VIN = 19 V

BATT charge voltage = set at 16.8 V

SW = ON

Efficiency η (%) =

(VBATT IBATT)

/ (VIN IIN) 100

2

4

6

8

10

12

14

16

18

20

BATT charge current IBATT (A)

BATT charge voltage VBATT (V)

BATT voltage vs. BATT charge current (set at 12.6 V)

18

 

 

 

Ta = +25 °C VIN = 19 V

 

 

16

 

BATT : Electronic load,

 

(V)

14

 

(Product of KIKUSUI PLZ-150W)

BATT

12

 

 

 

 

 

V

10

 

 

 

 

 

 

 

 

 

 

voltage

Dead Battery MODE

 

DCC MODE

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

BATT

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

DCC : Dynamically-Controlled

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

BATT voltage vs. BATT charge current (set at 16.8 V)

 

20

 

 

 

BATT : Electronic load,

 

 

 

18

 

 

 

 

 

 

 

 

 

(Product of KIKUSUI PLZ-150W)

 

(V)

 

 

 

 

 

16

 

 

 

 

 

 

 

Ta = +25 °C

 

BATT

14

 

 

 

 

 

 

 

VIN = 19 V

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

Dead Battery MODE

 

DCC MODE

 

voltage

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

BATT

6

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

DCC : Dynamically-Controlled

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

BATT charge current IBATT (A)

BATT charge current IBATT (A)

(Continued)

27

Image 27
Contents Features DescriptionPackage MB3887 TOP View PIN AssignmentPIN Description Pin No Symbol DescriptionsBlock Diagram Absolute Maximum Ratings Parameter Symbol Conditions Rating Unit Min MaxRecommended Operating Conditions Parameter Symbol Conditions Value Unit Min TypElectrical Characteristics Parameter Sym Pin ConditionsBol Min Typ Parameter Sym Pin Conditions Value Unit Bol Min Typ Max Parameter Sym Pin Conditions Value Unit Bol Min Typ OUT = −45 mA Output block Resistor Typical Characteristics Triangular wave oscillation frequency fOSC kHz Error amplifier gain and phase vs. Frequency Gain a Power dissipation vs. Ambient temperature Functional Description Control block CTL PowerPWM comparator block PWM Comp Output block OUTSoft-start block Soft Setting the Charging VoltageMethod of Setting the Charging Current Method of Setting the Triangular Wave Oscillation FrequencyMethod of Setting the SOFT-START Time AC Adaptor Voltage Detection Operation Timing DiagramConnection when Current Amp is not used Processing Without Using the Current AMPConnection when Error Amp is not used Processing Without Using of the Error AMPConnection when soft-start time is not specified Processing Without Using of the CS TerminalAt 4 cell Application ExampleParts No Parts ListReference Data Batt Vbatt mV Ta = +25 C, VIN = 19 Batt = 12 Ω Usage Precautions Ordering InformationPart number Package Remarks Index Package DimensionFujitsu Limited