Fujitsu MB3887 manual Absolute Maximum Ratings, Parameter Symbol Conditions Rating Unit Min Max

Page 6

MB3887

ABSOLUTE MAXIMUM RATINGS

Parameter

Symbol

Conditions

 

Rating

Unit

 

 

 

Min

 

Max

 

 

 

 

 

 

 

 

 

 

 

 

Power supply voltage

VCC

VCC, VCC (O) terminal

 

28

V

 

 

 

 

 

 

 

Output current

IOUT

 

60

mA

 

 

 

 

 

 

 

Peak output current

IOUT

Duty 5 %

 

700

mA

(t = 1 / fOSC Duty)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power dissipation

PD

Ta ≤ +25 °C

 

740*

mW

 

 

 

 

 

 

 

Storage temperature

TSTG

55

 

+125

°C

 

 

 

 

 

 

 

* : The package is mounted on the dual-sided epoxy board (10 cm 10 cm) .

WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.

6

Image 6
Contents Features DescriptionPackage MB3887 PIN Assignment TOP ViewPin No Symbol Descriptions PIN DescriptionBlock Diagram Parameter Symbol Conditions Rating Unit Min Max Absolute Maximum RatingsParameter Symbol Conditions Value Unit Min Typ Recommended Operating ConditionsElectrical Characteristics Parameter Sym Pin ConditionsBol Min Typ Parameter Sym Pin Conditions Value Unit Bol Min Typ Max Parameter Sym Pin Conditions Value Unit Bol Min Typ OUT = −45 mA Output block Resistor Typical Characteristics Triangular wave oscillation frequency fOSC kHz Error amplifier gain and phase vs. Frequency Gain a Power dissipation vs. Ambient temperature Functional Description Output block OUT PowerPWM comparator block PWM Comp Control block CTLMethod of Setting the Triangular Wave Oscillation Frequency Setting the Charging VoltageMethod of Setting the Charging Current Soft-start block SoftMethod of Setting the SOFT-START Time Operation Timing Diagram AC Adaptor Voltage DetectionProcessing Without Using the Current AMP Connection when Current Amp is not usedProcessing Without Using of the Error AMP Connection when Error Amp is not usedProcessing Without Using of the CS Terminal Connection when soft-start time is not specifiedApplication Example At 4 cellParts List Parts NoReference Data Batt Vbatt mV Ta = +25 C, VIN = 19 Batt = 12 Ω Usage Precautions Ordering InformationPart number Package Remarks Package Dimension IndexFujitsu Limited