| Family 2785+01 IBM Infoprint 2085 | 
 | 
| SW=Swedish HU=Hungarian | K=Korean | 
| CZ=Czech | 
 | 
The CE will setup two languages for the operator panel at installation time.
Physical Specifications
Size and Weight
Unpacked size and weight are as follows:
| 
 | Width | Depth | Height | Weight | 
 | ||
| 
 | 
 | ||||||
| Base Printer | 2106mm (69.8") | 735mm (28.9") 1476mm | (58.1") | 302kg | (664 | lb) | |
| Printer+HCF | 2314mm (91.1") | 735mm (28.9") | 1476mm | (58.1") | 381kg | (838 | lb) | 
Note: " denotes inches.
Operating Environment
●Infoprint 2085:
❍Operating Temperature: 50 to 90 deg F (10 to 32 deg C)
❍Humidity: 15 to 85% RH; 26 deg C max wet bulb
❍Altitude: 8,200 ft (2500 m)
Electrical Specifications
●North America - 208 Volt, 60 Hz
●Europe - 
●Japan - 200 Volt, 50/60 Hz
| Power Consumption | 
 | 
 | 
 | 
 | 
 | 
| Less than 3,000 Watts. | 
 | 
 | 
 | 
 | 
 | 
| Acoustics | 
 | 
 | 
 | 
 | 
 | 
| Mode | Infoprint 85 | Infoprint 105 | Remark | ||
| Operating | 78 | dB(A) | 80 | dB (A) | Sound Power | 
| Idle | 63 | dB(A) | 69 | dB (A) | Sound Power | 
| Operator position | 72 | dB(A) | 74 | dB (A) | Sound Pressure | 
| User Position | 72 | dB(A) | 74 | dB (A) | Sound Pressure | 
Ozone Emissions
Infoprint 2085 and 2105 ozone emissions are less than 0.02 mg/hr in the continuous copying mode.
Limitations
Not applicable.
http://gsmserv.boulder.ibm.com/cd/usmhw/M2785$01.htm (36 of 47)5/25/2005 7:01:07 AM