Cisco Systems 2020 manual Installing Fantails, Required Tools and Equipment

Page 8

Installing Fantails

Step 7 Repeat the procedure above if the LS2020 switch contains a second DC power tray.

Step 8 Observe the green power LED on the front of the power tray when power is applied. If the LED is not lit, check for incorrectly connected wires or problems in the DC power source.

Installing Fantails

This section explains how to mount and connect fantails in your LS2020 switch (see Figure 2-4). Fantails provide connectors for data cables on low-speed(V.35, X.21 and EIA/TIA-449) lines and T3 lines that are attached to cell line card/T3 access cards in an LS2020 switch.

If your system has no low-speed or cell line card/T3 modules, skip to the section “Attaching Data Cables.”

Required Tools and Equipment

Obtain the following equipment and tools in preparation for installing fantails:

Fantails in the desired quantity (provided by Cisco Systems).

Required fantail cables (provided by Cisco Systems).

Fantail mounting screws, clip nuts, and washers (provided by Cisco Systems). If your equipment rack has metric-threaded rails, you must provide appropriate mounting screws.

A 5/16-inch slotted-tip screwdriver.

Adhesive labels for making appropriate notations on each fantail.

A grounding wrist strap for ESD protection during fantail installation.

Note If you are installing X.21 fantails and you plan to configure the ports as DTEs, you must obtain and install a 15-pin male-to-male gender converter on each port in order to change the female connector to a male connector. Note, however, that the gender converters are not required for X.21 ports configured as DCEs.

2-8LightStream 2020 Installation Guide

Image 8
Contents Hardware Installation Unpacking and Inspecting the LS2020 Switch HardwareInstalling an LS2020 Switch in Rack Cooling Air and Hardware PlacementRack Installation Procedure Required ToolsInstalling an LS2020 Switch in Rack 2020 Rear View of AC-powered LightStream 2020 Chassis Wiring a DC-Powered System Preparation for WiringWiring Procedure Connections to DC-powered ChassisInstalling Fantails Required Tools and EquipmentFantail Installation Procedure Fantail Cable ConnectionsConnecting Cables Applying System Power Closing the ChassisTerminal Power switch Block Power inlet Switch Installing Modems LightStream 2020 Power-up SequenceRequired Configuration Information PasswordsBasic LS2020 Configuration Tasks Host Name IP Addresses and MasksTrunk Port Information Background Information Setting Console/Modem Baud Rates through TCS Hub CommandsAttaching a Terminal to a Console Port For the Modem Port Attaching a Terminal and Matching the Baud Rate Method20LightStream 2020 Installation Guide Connecting the Terminal to the NP Special Consideration Running Scripts Separately Entering Configuration Data Second Enter date prompt confirms the initial date entry Host name LightStream1 26LightStream 2020 Installation Guide Host Name LightStream1 28LightStream 2020 Installation Guide Password password Return How to Proceed Running DiagnosticsStarting Maintenance Log Installing StreamView Network Management SoftwareIf Your PC Has Two 1.44-MB Floppy Disk Drives Configuring the NetworkBacking Up Distribution Diskettes If Your PC Has One 1.44-MB Floppy Disk Drive \ diskcopy a a /v