Cisco Systems 6503 manual Cisco Catalyst OS Image Upgrade Procedure

Page 10
Cisco Catalyst OS Image Upgrade Procedure

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/ol_1982.htm - xtocid8

Cisco Catalyst OS Image Upgrade Procedure

Based on the discussion above, the following procedure is recommended for performing a software upgrade with the minimal downtime associated with the High Availability feature. High-availability compatibility between the images will be determined in the middle of the procedure. The MSFC is affected by this procedure, but is discussed in the section “MSFC High Availability Features.”

In this example, the supervisor engine in slot 1 (Sup-A) will begin in active mode and the supervisor engine in slot 2 (Sup-B) will begin in standby mode. It is recommended that a console connection be available for both supervisors for this procedure.

1. Disable the High Availability feature on the active supervisor engine.

Sup-A> (enable) set system highavailability disable

This feature is disabled by default.

2. Load the new Cisco Catalyst OS software image into the boot Flash of the active supervisor engine (via slot 0, Trivial File Transfer Protocol [TFTP], etc.).

Sup-A> (enable) copy slot0:cat6000-sup2k8.7-2-2.bin bootflash:cat6000-sup2k8.7-2-2.bin

3. Verify that the new image was loaded successfully into the boot Flash of the active supervisor engine.

Sup-A> (enable) dir bootflash:

4. Clear the current boot variable.

Sup-A> (enable) clear boot system all

5.Set the boot variable on the active supervisor engine to the new Cisco Catalyst OS software image.

6.Sup-A> (enable) set boot system flash bootflash:cat6000-sup2k8.7-2-2.bin

In approximately 120 seconds, the image set as the boot entry on the active supervisor engine will be copied to the boot Flash on the standby supervisor engine (this is the image synchronization). This is an internal TFTP of the Cisco Catalyst OS image file and takes a few minutes to complete. The image file will have a BTSYNC appended to the beginning of the filename to designate that it has been synchronized from the active supervisor engine’s boot-time image.

7. After synchronization, verify that the new image is located on the standby supervisor engine and the boot variable is properly set.

Sup-A> (enable) dir 2/bootflash:

Sup-A> (enable) show boot 2

The new Cisco Catalyst OS image is now on both supervisor engines. 8. Enable high-availability versioning on the active supervisor engine.

Sup-A> (enable) set system highavailability enable

Sup-A> (enable) set system highavailability versioning enable

You must enable versioning before the standby supervisor engine running the new software becomes active. This allows the standby supervisor engine to reboot under the new version of Cisco Catalyst OS while remaining in standby mode.

9.It is the intent of these upgrade procedures to allow for a fallback plan of using the old Cisco Catalyst OS image. The now-active supervisor engine must maintain that older image (even after an accidental reboot). Therefore, the boot variable on the active supervisor engine must be changed to its original setting, which should still be stored in the boot

Flash.

Sup-A> (enable) set boot system flash bootflash:cat6000-sup2k8.old.bin

Note: Since versioning is enabled, the setting of the boot variable does not cause an image synchronization.

Cisco Systems, Inc.

All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.

Page 10 of 19

Image 10
Contents High Availability for the Cisco Catalyst 6500 Series Switches White PaperSwitching Fabric Failover Switch Fabric Module RedundancySwitching Fabric Operation Example 1 Fabric-Enabled System CLI output description for show fabric channel switchmodeExample 2 Classic and Fabric-Enabled System Supervisor Fast Switchover Supervisor Engine SwitchoverRedundant Supervisor Engines Supervisor Stateful Protocol Redundancy Supervisor High Availability FeatureSup-A enable set system highavailability enable and incompatible Protocol Database Supervisor Engine Software Image UpgradesSupervisor Engine Image Synchronization Standby SupervisorSupervisor Engine Versioning Feature Sup-A enable show system highavailabilityCisco Catalyst OS Image Upgrade Procedure 6. Sup-A enable set boot system flash bootflashcat6000-sup2k8.7-2-2.binMSFC High Availability Features Dual Router Mode MSFC Configuration SynchronizationDRM Operation WAN Interfaces in DRM DRM ChallengesSingle Router Mode SRM OperationSRM Configuration and Conversion Procedure WAN Interfaces in SRMSRM and IP Multicast Supervisor and MSFC Failover TestsRedundant Power Supplies Conclusion Americas Headquarters Corporate HeadquartersEuropean Headquarters Asia Pacific Headquarters