Cisco Systems C3850NM41G, WSC385024TS manual Table- or Shelf-Mounting, After Installing the Switch

Page 50

Chapter 2 Switch Installation

Installing the Switch

Table- or Shelf-Mounting

To install the switch on a table or shelf, locate the adhesive strip with the rubber feet in the mounting-kit envelope. Attach the four rubber feet to the recessed areas on the bottom of the chassis (see Figure 2-14).

Figure 2-14 Attaching the Adhesive Pads for Table- or Shelf-Mounting

PWR-C1-715WAC

PWR-C1-715WAC

 

PWR-C1-715WAC

CONSOLE

MGMT

1

4049

1

 

33

1

Adhesive pads

When you complete the switch installation, see the “After Installing the Switch” section on page 2-16for more information switch configuration.

After Installing the Switch

After the switch is installed, you might need to:

Configure the switch by running Express Setup to enter the initial switch configuration. For instructions, see the switch getting started guide that shipped with the switch and also on Cisco.com.

Use the CLI setup program to enter the initial switch configuration. See Appendix C, “Configuring the Switch with the CLI-Based Setup Program.”

Connect to the front-panel ports. See the “Installing a Network Module in the Switch” section on page 3-4and the “Connecting Devices to the Ethernet Ports” section on page 2-19.

 

Catalyst 3850 Switch Hardware Installation Guide

2-16

OL-26779-02

Image 50
Contents Catalyst 3850 Switch Hardware Installation Guide Page N T E N T S Installing and Removing SFP and SFP+ Modules Grounding the Switch Power Supply Module Specifications A-2 Installing the Cisco Microsoft Windows USB Device Driver C-4 Viii Document Conventions PrefacePurpose Obtaining Documentation and Submitting a Service Request Related DocumentationSwitch Models, Front Panel, Rear Panel, Management Options, Product OverviewSwitch Models Switch Model Cisco IOS Image DescriptionSwitch Model Cisco IOS Image Description Catalyst 3850-48P-L Switch Front Panel Front Panel10/100/1000 Ethernet Ports PoE, PoE+, and Cisco Upoe PortsManagement Ports USB Mini-Type B PortUSB Type a Port Network ModulesSFP and SFP+ Modules Network Module DescriptionLEDs 3 4 5Color System Status Color XPS StatusPort LEDs and Modes Mode LED Port Mode DescriptionPort Mode Port LED Color Meaning 10/100/1000/SFP ports USB Console LED ColorActv LED Color DescriptionColor Status of PoE mode PoE, PoE+, or Cisco Upoe PoE LEDNetwork Module LEDs Color Network Module Link StatusRJ-45 Console Port Status Rear PanelRJ-45 Console Port LED Power Supply Modules StackWise PortsPoE Option Port Switch Models Default Power Supply Available PoENumber of Power Models Supplies Available PoE PoE Option Port Switch Fan Modules AC-Power Supply Module LEDsDC-Power Supply Module LEDs StackPower Connector Fan Module DescriptionRJ-45 Console Port Management OptionsEthernet Management Port Network Configurations Safety Warnings Switch InstallationPreparing for Installation OL-26779-02 Installation Guidelines Powering Off the Switch Planning a Switch Data StackVerifying Switch Operation Tools and EquipmentData Stack Cabling Configurations Switch Stacking and Power Stacking GuidelinesData Stack Bandwidth and Partitioning Examples 344185Power-On Sequence for Switch Data Stacks Example of a Data Stack with a Failover ConditionPlanning a StackPower Stack StackPower Stacking GuidelinesStackPower Cabling Configurations Part Number Cable Type LengthStackPower Ring Topology Installing the Switch StackPower Partitioning ExamplesRack-Mounting Attaching the Rack-Mount Brackets 11 Rack-Mounting Brackets12 Attaching Brackets for 19-inch Racks Mounting the Switch in a Rack 13 Mounting the Switch in a RackAfter Installing the Switch Table- or Shelf-MountingConnecting to the StackWise Ports Cisco logo Connector screwConnecting to the StackPower Ports 16 Connecting the StackPower Cable to a StackPower PortConnecting Devices to the Ethernet Ports Installing a Network Module in the SwitchInstalling and Removing SFP and SFP+ Modules 10/100/1000 Ethernet Port ConnectionsPoE+ and Cisco Upoe Port Connections Device Crossover CableWhere to Go Next OL-26779-02 Installing a Network Module OverviewCaptive screws Gigabit Ethernet ports Blank module Captive screws Network Module LEDs Color Link StatusInstalling Network Modules Installing the Network Module in the Switch C3850-NM-4-10G module Configuring a Network ModuleC3850-NM-4-1G module Interface ActionTenGigabitEthernet GigabitEthenet C3850-NM-2-10G moduleSupported GBICs SFP and SFP+ Modules Installing SFP and SFP+ ModulesRemoving a Network Module Installing an SFP Module in the Network Module Finding the Network Module Serial Number Removing SFP or SFP+ ModulesNetwork Module Serial Number Location Part Number Description Power Supply InstallationPower Supply Module Overview AC OK LED AC Power Supply Module 6 5 DC Power Supply Module LEDs Installation GuidelinesAC Power Supply Module LEDs Installing or Replacing an AC Power Supply Installing a DC Power Supply Inserting the AC-Power Supply in the SwitchGrounding the Switch Equipment That You NeedStripping the Ground Wire 10 Attaching the Ground Lug and Wire Assembly Installing the DC Power Supply in the Switch Wiring the DC Input Power SourceFinding the Power Supply Module Serial Number 12 DC Source a Isolated From Source B with No Common Ground14 1100-W AC Power Supply Serial Number 16 440-W DC Power Supply Module Serial Number Installing the Fan Fan Module Installation Installing a Fan ModuleInstalling the Fan Module Finding the Fan Module Serial NumberFan Module Serial Number Switch Post Results TroubleshootingDiagnosing Problems Switch LEDsEthernet and Fiber Cables Switch ConnectionsBad or Damaged Cable Link StatusSFP Modules 10/100/1000 Port ConnectionsPoE and PoE+ Port Connections Ping End Device Switch PerformanceInterface Settings Spanning Tree LoopsCabling Distance Resetting the SwitchAutonegotiation and Network Interface Cards Finding the Switch Serial Number Replacing a Failed Data Stack MemberPhysical Specifications Technical SpecificationsSwitch Specifications Environmental RangesPower Supply Module Specifications Power SpecificationsPower Specifications Operating Specification Fan Module SpecificationsPhysical Specification 10/100/1000 Ports Connector and Cable SpecificationsConnector Specifications Gigabit Ethernet CX1 SFP+ Copper Connectors SFP and SFP+ ModulesFigure B-4 Simplex LC Cable Connector 10/100/1000 Ethernet Management PortConsole Port Figure B-7 10/100 Port PinoutsStackWise Cables Cable and Adapter SpecificationsSFP and SFP+ Module Cable Specifications Four Twisted-Pair Cable Pinouts Two Twisted-Pair Cable PinoutsConsole Port Adapter Pinouts Switch Console RJ-45-to-DB-9 Port DTEIdentifying a Crossover Cable DeviceGND Switch Console RJ-45-to-DB-25 Port DTE OL-26779-02 Accessing the CLI Through Express Setup Configuring the Switch with the CLI-Based Setup ProgramAccessing the CLI Accessing the CLI Through a Console Port USB Console Port344194 Installing the Cisco Microsoft Windows USB Device Driver Uninstalling the Cisco Microsoft Windows USB DriverConfiguring the Setup Program Entering the Initial Configuration InformationIP Settings Enter an enable password, and press Return These choices appear OL-26779-02

C3850NM41G, C3850NM210G, WSC385024TS specifications

Cisco Systems is a global leader in networking and telecommunications hardware, and its Catalyst series of switches are widely recognized for their innovation, reliability, and performance. Among the numerous models available, the Cisco WSC385024TS, C3850NM41G, and C3850NM210G stand out for their advanced features and capabilities tailored to meet the needs of modern enterprises.

The Cisco WSC385024TS is a stackable switch that offers 24 ports, and it is built on Cisco's IOS XE software. It is designed for high-density environments, making it ideal for organizations that require robust connectivity and scalability. This model supports advanced Layer 2 and Layer 3 features and facilitates intelligent traffic management through Quality of Service (QoS). One of its standout features is the ability to stack up to nine switches together, enabling centralized management and increased fault tolerance. The WSC385024TS also integrates security features such as 802.1X authentication and access control lists, which are essential for maintaining a secure network infrastructure.

The C3850NM41G is a versatile switch that comes with 41 Gigabit Ethernet ports, making it suitable for environments that demand high-speed connectivity. This model supports Cisco's innovative StackWise-480 technology, which provides increased bandwidth and reliable inter-switch communication. Additionally, it features Power over Ethernet (PoE) capabilities, allowing it to deliver power to connected devices such as IP phones and wireless access points, thereby simplifying cabling and reducing the need for additional power sources. The C3850NM41G is also equipped with built-in automatic fault detection and recovery, enhancing the overall resilience of the network.

Lastly, the C3850NM210G model offers 210 Gbps of switching capacity, making it ideal for data-intensive applications. This switch combines performance with security, supporting various security protocols such as Virtual Routing and Forwarding (VRF) and Dynamic Host Configuration Protocol (DHCP) snooping to protect against malicious activity. With its modular design, the C3850NM210G allows for easy upgrades and expansions, facilitating adaptive network growth.

In summary, the Cisco WSC385024TS, C3850NM41G, and C3850NM210G switches provide advanced features, robust performance, and high scalability, making them ideal choices for businesses aiming to enhance their network infrastructure while supporting cutting-edge technologies. Whether for small businesses or large enterprises, these models exemplify Cisco's commitment to delivering high-quality networking solutions that adapt to the evolving demands of today's digital landscape.