Cisco Systems Cisco 7000, Cisco 7507 installation instructions Installing the Chassis in the Rack

Page 21

Installation

Follow these steps to install the ears on the chassis:

Step 1 While referring to Figure 12, position the ears on the chassis as follows:

To flush-mount the chassis (so that the end of the chassis is approximately flush with the rack posts): Place each ear so that the mounting strips are flush with the end of the chassis, and align the mounting holes in the ear with those in the chassis.

If you are attaching the ears to the noninterface processor end (front) of the chassis, the mounting strips on the ears will extend slightly past the ends of the chassis. To protect the plastic front bezel and LED windows, the front of the chassis will be slightly recessed into the rack.

To center-mount the chassis (so that the chassis is roughly centered in a Telco-type rack): Place each ear with the mounting strips away from the end of the chassis, and align the mounting holes in the ear with those in the chassis.

Step 2 Use two M4 x 10-mm, flat-head Phillips screws to secure each ear to the chassis.

Proceed to the next section to install the chassis in the rack.

Installing the Chassis in the Rack

Two people are required to lift the chassis and complete this part of the installation. You will need to lift the chassis and slide it into the rack and onto the ledges provided by the brackets. After you push the chassis back into the rack, you will attach the ears to the rack-mounting strips to prevent the chassis from sliding forward or backward out of the rack.

Before moving the chassis, you must remove all power supplies and disconnect all power and interface cables. If you are installing a new chassis, or if you have already removed all power supplies and disconnected all interface cables, proceed to the section “Moving the Chassis into the Rack” on page 22.

Removing Power Supplies and Interface Cables

Before moving the chassis, you must remove all power supplies and disconnect all power and interface cables. Label the interface cables; you can use the configuration worksheet provided at the end of this document to record the correct cable connections and avoid crossing cables when you reconnect them. (For the Cisco 7000, see Figure 16 on page 27, and for the Cisco 7507, see Figure 17 on page 28.)

The power supply switch is also an interlock tab that prevents the supply from being removed when it is on. (See Figure 6 on page 11.) The interlock tab extends into a slot in the chassis when the power switch is on, and retracts into the power supply to allow removal when the switch is off.

Follow these steps to install the chassis in the rack:

Step 1 Turn OFF all installed power supplies.

Step 2 Disconnect the power cords from the source power connection first, then from the power supply receptacle. Push the cable retention clip down to free the plug, then pull the cord out of the power receptacle.

Step 3 Loosen the captive installation screw at the top of the first power supply. (See Figure 13.)

Step 4 Grasp the power supply handle and slowly pull the supply out of the bay. Keep your other hand underneath the bottom to support it. (See Figure 13.)

Step 5 Put the power supply aside.

Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 21

Image 21
Contents Doc. No Equipment Rack Descriptions Rack-Mount Kit OverviewMounting Kit Hardware Rack-Mount Installation SummaryShows the components in this mounting kit Typical Center-Mount Installation Shows a typical flush-mount installation Prerequisites Safety Guidelines Working with Electrical EquipmentLifting the Chassis Safely Lifting Safely Safety with Electricity Equipment Rack Considerations Power Supply Safety Interlocks-AC-Input Power Supply ShownPower supply/interface processor end Rack StabilityPlastic front panel end Chassis Center of Gravity for Flush-Mount Configurations Rack Ventilation Rack Dimensions and Site LayoutParts List List of Parts and ToolsTools Required Installing the Brackets InstallationMounting the Brackets to the Rack Posts Installing a Bracket on a Rack Post-Left Bracket ShownSecuring the Spanner Bars Positioning and Fastening a Spanner Bar Attaching the Chassis Ears Installing the Ears on the ChassisRemoving Power Supplies and Interface Cables Installing the Chassis in the RackMoving the Chassis into the Rack Handling a Power Supply AC-Input Power Supply ShownChassis Foot Underside of chassisSliding the Chassis into the Rack Checking Electrical IsolationReplacing Power Supplies and Interface Cables Restarting the System Router name Prepared by Location Date Slot Circle one Chassis serial number Slot Circle oneRouter name Prepared by Location Date RSP2Power Supply Warning Power Disconnection WarningPower Supply Disconnection Warning Electric Shock Warning Chassis Lifting Warning DC Power Disconnection Warning Lightning Activity Warning Chassis Warning-Rack-Mounting and Servicing Translated Safety Warnings Ramp Warning Cisco Information Online